• Title/Summary/Keyword: Intraoral

Search Result 886, Processing Time 0.023 seconds

A study on the perception of dental hygienists according to the clinical application experience of digital intraoral scanners: focusing on the comparison with conventional impression (구강 스캐너 임상적용 경험에 따른 치과위생사의 인식 연구: 전통적 인상채득과의 비교를 중심으로)

  • Myoung-Hee, Kim;Young Sun, Hwang;Hang-Sik, Park
    • Journal of Korean Academy of Dental Administration
    • /
    • v.10 no.1
    • /
    • pp.84-92
    • /
    • 2022
  • Impression taking is one of the most frequently performed tasks within the legal scope of dental hygienists. This study aims to compare traditional impression and digital impression taking in various aspects with dental hygienists who have experience using digital intraoral scanners. A total of 61 subjects were included in this analysis. Traditional and digital impression taking were compared, and the perception of intraoral scanners was classified into four factors through exploratory factor analysis. After a normality test of the main variables was performed, a non-parametric test was performed. In terms of the adequacy of the size of the tool inserted into the oral cavity, traditional impression taking was more positive, and there was no significant difference in the precision of impression taking, fit of the prosthesis, and time efficiency. In contrast, the digital intraoral scanner was positive in terms of reducing nausea. In the comparison between the items of the digital intraoral scanner, relatively low satisfaction was shown in terms of convenience of use. This study compared traditional impression taking based on the experience of dental hygienists using oral scanners. It is hoped that this will be one step closer to universalization. In addition, appropriate training on how to use them should be provided.

A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

A novel method for testing accuracy of bite registration using intraoral scanners

  • Lydia Kakali;Demetrios J. Halazonetis
    • The korean journal of orthodontics
    • /
    • v.53 no.4
    • /
    • pp.254-263
    • /
    • 2023
  • Objective: The evidence on the accuracy of bite registration using intraoral scanners is sparse. This study aimed to develop a new method for evaluating bite registration accuracy using intraoral scanners. Methods: Two different types of models were used; 10 stone models and 10 with acrylic resin teeth. A triangular frame with cylindrical posts at each apex (one anterior and two posteriors) was digitally designed and manufactured using three-dimensional (3D) printing. Such a structure was fitted in the lingual space of each maxillary and mandibular model so that, in occlusion, the posts would contact their opposing counterparts, enforcing a small interocclusal gap between the two arches. This ensured no tooth interference and full contact between opposing posts. Bite registration accuracy was evaluated by measuring the distance between opposing posts, with small values indicating high-accuracy. Three intraoral scanners were used: Medit i500, Primescan, and Trios 4. Viewbox software was used to measure the distance between opposing posts and compute roll and pitch. Results: The average maximum error in interocclusal registration exceeded 50 ㎛. Roll and pitch orientation errors ranged above 0.1 degrees, implying an additional interocclusal error of around 40 ㎛ or more. The models with acrylic teeth exhibited higher errors. Conclusions: A method that avoids the need for reference hardware and the imprecision of locating reference points on tooth surfaces, and offers simplicity in the assessment of bite registration with an intraoral scanner, was developed. These results suggest that intraoral scanners may exhibit clinically significant errors in reproducing the interocclusal relationships.

Dental hygienists' Needs for Convergence Education according to the Use of Digital Intraoral Scanners (치과위생사의 디지털 구강스캐너 사용에 따른 융합적 교육 요구도)

  • Kang, Hyun-Kyung;Lee, Sook-Jeong;Jang, Kyeung-Ae;Heo, Seong-Eun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.5
    • /
    • pp.69-75
    • /
    • 2018
  • The purpose of this study was to investigate the systematic and convergent education needs according to the use of digital intraoral scanners in dental hygienists. Data of 127 respondents who participated in an online survey for dental hygienists working at dental hospitals and clinics were analyzed by the frequency analysis, t-test, one way ANOVA, and correlation using SPSS 24.0 program. The utilization period of digital intraoral scanners in the hospital was 'less than 1 year' in 78.7%. As for relevant education experience, 58.3% answered 'no', showing a higher proportion of no education experience. As for clinical application of digital intraoral scanners, 77.4% responded that they use the scanner for clinical purposes. With regard to digital intraoral scanner education, 61.4% responded that education is necessary. This result reflects the fact that digital intraoral scanners have been rapidly introduced to dental hospitals and clinics, but systematic education has not been given. Therefore, we hope that this paper will be used as basic data to recognize the need for education on digital intraoral scanners.

A CLINICAL STUDY ON SUPERIORLY BASED PLATYSMA MYOCUTANEOUS CERVICAL FLAP FOR RECONSTRUCTION FOLLOWING INTRAORAL SOFT TISSUE CANCER SURGERY (구강내 연조직 암 절제후 상부기조 광경근 근피부 경부 피판을 이용한 구강내 재건에 관한 임상적 연구)

  • Park, Bong-Wook;Byun, June-Ho;Shin, Hee-Suk;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.83-91
    • /
    • 2008
  • The goal of reconstruction following ablative therapy for intraoral cancer is the restoration of form and function to permit a return to activities of daily life. Traditional reconstruction includes split thickness skin grafts, myocutaneous flaps and, more recently, various free flaps. Free flaps provide higher level of functional recovery relative to that seen with other techniques but require the complexity of the technique and microvascular anastomosis and thus, extended surgical time and occasionally a second team for harvesting. The platysma myocutaneous cervical flap is a possible alternative for intraoral reconstruction. It is thin and pliable like the tissue provided by the radial forearm free flap. It can be harvested with enough tissue to close most head and neck ablative defects. There is virtually no donor site morbidity involved. This study evaluated 7 patients affected by intraoral squamous cell carcinoma (SCC). All patients underwent the resection of intraoral SCC with neck dissection and subsequent intraoral reconstruction with the superiorly based platysma myocutaneous cervical flap. Flap-related complications occurred in 3 patients. Adjuvant radiation therapy was performed in 3 patients. Average follow-up was 24.1 months after surgery, with a range of 8 to 42 months. All patients presented self assessment of discomfort associated with intraoral recipient sites and cervical donor sites. However, the neck function measured by two-inclinometer technique was within the normal range during relatively long term follow-up period. Our study concluded that superiorly based platysma myocutaneous cervical flap is good alternative to free flaps, especially for relatively smaller defects and for the defects appropriate for the rotation arc of the flap.

Surgical Treatment of a Plunging Ranula using the Intraoral and Submandibular Approach (구강 내 접근과 하악하 절개를 통한 몰입성 하마종의 수술적 치료)

  • Kim, Jung Hong;Eun, Seok Chan;Baek, Rong Min
    • Archives of Craniofacial Surgery
    • /
    • v.11 no.2
    • /
    • pp.111-115
    • /
    • 2010
  • Purpose: A plunging ranula is relatively uncommon and represents a mucus escape reaction occurring from a disruption of the sublingual salivary gland. It is a common condition found in young adults, even though the reported age range is 2 - 61 years. We report our experience of a complete excision of a plunging ranula via the intraoral and submandibular approach. Methods: A 23-year-old man had a large protruding mass in the right submandibular area. Initially, the protruding mass appeared bilaterally but the left side disappeared spontaneously. The MRI findings revealed a homogenous fluid attenuation mass in the submandibular space, suggesting a ranula. The sublingual gland was extirpated through the intraoral approach and the ranula excised totally via the submandibular approach. Results: The patient had an uneventful postoperative course without infection, paralysis and tongue sensory changes, etc. The pathology findings were characteristic of a pseudocyst without a lining epithelium or endothelium but with a vascular fibro-conective tissue wall filled with mucinous fluid. No recurrence was observed on the submandibular area during the 8 month follow-up period. Conclusion: The combined intraoral approach and submandibular approach is an effective and highly recommended method for sublingual gland extirpation and complete excision of a plunging ranula.

Strain elastography of palatal tumors in conjunction with intraoral ultrasonography, computed tomography, and magnetic resonance imaging: 2 case reports

  • Ogura, Ichiro;Toshima, Hiroo;Akashiba, Tohru;Ono, Junya;Okada, Yasuo
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.73-79
    • /
    • 2020
  • Computed tomography (CT) and magnetic resonance imaging (MRI) can be useful for the evaluation of palatal lesions, and strain elastography (performed together with intraoral ultrasonography) is a relatively new sonographic imaging modality. This report describes 2 clinical cases in which strain elastography was used to assess palatal tumors in conjunction with intraoral ultrasonography, CT, and MRI. In the first case, diagnosed as a myoepithelioma, the strain was determined to be 0.000% (strain of normal tissue, 0.556%). In the second case, diagnosed as an adenoid cystic carcinoma, the determined strain was 0.000% (strain of normal tissue, 1.077%). Therefore, we conclude that intraoral strain elastography can be useful for evaluating palatal lesions.

Quantitative Analysis for Digital Intraoral Sensor (구강 내 촬영용 센서의 정량적 평가)

  • Jung, Jae-Ho;Jung, Jae-Eun;Kang, Hee-Doo;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.109-114
    • /
    • 2009
  • Carried out an experiment for quantitative evaluation about intraoral sensor among oral dental imaging equipments in PACS environment. For evaluation, testing environment & evaluation criteria are established that refer to the 'IEC 62220-1-2' and experimented with set up the standard radiation penetration that correspond with RQA-3(IEC 61267). Results of experiments using the image J, derived the ESF(edge spread function), LSF (line spread function) and calculated the MTF(modulation transfer function) finally. As a result, the MTF that 0.1, 0.2sec are 10% about 10 lp/mm and 0.32 sec is the 10% about 9 lp/mm in level represents the value of the MTF. Change of scan condition in dental environmental, according to the MTF value taken note that no changes can be seen enough. However, the dimensions of each other size $1(1200{\times}1600)$, size $2(1440{\times}1920)$ intraoral sensors for 3 lp/mm, respectively 40%, 90% of the note might have been the difference between the value of MTF, in accordance with standard sensors might note differences could be observed.

  • PDF

Unilateral intraoral vertical ramus osteotomy based on preoperative three-dimensional simulation surgery in a patient with facial asymmetry

  • Lee, Jae-Won;Kim, Moon-Key;Kang, Sang-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • Preoperative surgical simulation in orthognathic surgery has progressed in recent years; the movement of the mandible can be anticipated through three-dimensional (3D) simulation surgery before the actual procedure. In this case report, the mandible was moved to the intended postoperative occlusion through preoperative surgical 3D simulation. Right-side condylar movement change was very slight in the surgical simulation, suggesting the possibility of mandibular surgery that included only left-side ramal osteotomy. This case report describes a patient with a mild asymmetric facial profile in which the mandibular menton had been deviated to the right and the lips canted down to the left. Before surgery, three-dimensional surgical simulation was used to evaluate and confirm a position for the condyle as well as the symmetrical postoperative state of the face. Facial asymmetry was resolved with minimal surgical treatment through unilateral intraoral vertical ramus osteotomy on the left side of the mandible. It would be a valuable complement for the reduction of the surgical treatment if one could decide with good predictability when an isolated intraoral vertical ramus osteotomy can be done without a compensatory osteotomy on the contralateral side.

A STUDY ON THE ENAMEL EROSION CAUSED BY ACIDIC BEVERAGE AND REHARDENING BY INTRAORAL EXPOSURE (산성 음료수에 의한 법랑질 침식과 구강내 재경화에 관한 연구)

  • Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.312-322
    • /
    • 1998
  • There are many concerns about the erosive effect of acidic beverage. In this study, the erosive effect of bovine enamel caused by $Pepsi-Cola^{(R)}$(pH 2.41) and rehardening effect by intraoral exposure were determined by microhardness test and SEM. The bovine enamel specimen was imbedded in 100ml $Pepsi-Cola^{(R)}$ during 5 minutes and exposed to the intraoral environment with removable resin plate. The microhardness test was performed after 1 hr, 24 hrs, and 48 hrs. The results obtained from this study can be summarized as follows ; 1. The microhardness value was significantly (p<0.05) reduced by cola beverage, and significantly (p<0.05) increased after 1 hr and 24 hrs respectively. 2. The difference in the microhardness between 24 hrs group and 48 hrs group was not significant (p>0.05) and microhardness value of 48 hrs group was significantly less than that of initial group (p<0.05). 3. The erosive effect of cola beverage and remineralization effect by intraoral exposure were visualized by the SEM photo. But, the enamel surfaces did not return to their original state.

  • PDF