• Title/Summary/Keyword: Intraocular pressure

Search Result 96, Processing Time 0.035 seconds

Intraocular Pressure Changes in the Uneventful Extra-capsular Cataract Extraction and Extra-capsular Cataract Extraction with Vitreous Loss followed by the Anterior Chamber Lens Implantation (계획적 수정체낭외적출술과 합병증이 동반된 수정체낭외적출술후 전방렌즈의 삽입술시 안압의 변화)

  • Park, Young-Hoon;Lee, Kyoo-Won;Hahn, Duk-Kee
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.1
    • /
    • pp.81-86
    • /
    • 1989
  • These days the posterior chamber lens implantation following the extracapsular cataract extraction has become the standard procedure except those patients who can not take it in one reason or another. In past, however, the anterior chamber lens implantation was popular for sometimes. Even now in those patient complicated by vitreous loss, the anterior chamber lens implantation following anterior vitrectomy is indicated in some cases. We have become interested in the difference of the intraocular pressure change in the patients who underwent the uneventful extra-capsular cataract extraction followed by anterior chamber lens implantation in routine manner and in those whose extra-capsular cataract extraction were complicated by vitreous loss and eventually needed the anterior vitrectomy before the anterior chamber lens implantation. We reviewed the medical records of 15 cases of the former group and 11 cases of the latter one in 1986 through 1988. There was some difference in the postoperative pressure in the two groups, but it was not statistically significant.

  • PDF

Body Mass Index Compared with Waist Circumference Indicators as a Predictor of Elevated Intraocular Pressure (안압상승의 위험인자로서 체질량지수(BMI)와 허리둘레의 비교)

  • Park, Sang-Shin;Lee, Eun-Hee;Paek, Domyung;Cho, Sung-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.293-297
    • /
    • 2010
  • Purpose: The aim of the current study was to compare body mass index (BMI) with waist circumference (WC) as a predictor of elevated intraocular pressure (IOP). Methods: The subjects were consisted of 458 adults, aged 20 year or above, of one community in Kyunggi-do. Mean IOPs were stratified jointly for BMI and WC tertiles. Multi-variate linear regression analysis was also used to compare between BMI and WC. Results: Although any BMI tertiles were not associated with IOP within each tertile of WC, WC tertiles was significantly related to elevation of IOP within the third BMI tertile (${\geq}24.9kg/m^2$). After adjusting for age and sex, only WC showed significant association with IOP. In additional adjustment for lifestyle variables, both BMI and WC were significantly associated with elevation of IOP. However, the results showed the stronger association of IOP with WC than BMI, whether they were adjusted by age and sex or additionally lifestyle variables. Conclusions: These data showed that BMI and WC were positively associated with IOP. However, WC appeared to be a better indicator for higher IOP than BMI.

Seasonal Variations of Intraocular Pressure in Normal Sapsaree Dogs (정상 삽살개 군에서의 계절별 안압 수치의 변화)

  • Chae, J. Jeremy;Jeong, Man-Bok;Choi, Joseph S.;Park, Shin-Ae;Yi, Nayoung;Kim, Won-Tae;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.95-99
    • /
    • 2013
  • This study was performed to evaluate the seasonal variation of intraocular pressure (IOP) values in normal Sapsaree dogs. Sapsaree dogs (n = 474) clinically free from ophthalmic disease were included in this study, and both eyes were examined in each dog. An applanation tonometer (Tonopen$^{(R)}$ XL) was used to measure IOP values in both eyes. Data obtained from both eyes were stratified by factors thought to affect IOP values including age, gender, hair coat type as well as season of measurement. The IOP results were compared by ANCOVA to verify the effect each factor had on IOP, and an ANOVA test followed by a Bonferroni post hoc test was used for further analysis. The overall mean ${\pm}$ SD IOP value was $19.1{\pm}3.7$ mmHg (range: 8 to 28 mmHg) in the present study. Only seasonal variation showed a significant effect (P < 0.001), on IOP values. IOP values measured in winter ($20.4{\pm}3.4$ mmHg) and summer ($17.1{\pm}3.6$ mmHg) were significantly higher and lower, respectively, than those measured in other seasons. These results suggest a seasonal variation has a significant effect on the IOP of normal dogs. This may prompt further research and possible modification of current veterinary ophthalmic references.

Intravitreal Gentamicin Injection in the Absolute and Blind Glaucoma Dogs: 13 Cases (실명한 절대 녹내장견에 대한 겐타마이신 초자체내 주사: 13두)

  • 김완희;강선미;권오경
    • Journal of Veterinary Clinics
    • /
    • v.19 no.4
    • /
    • pp.461-463
    • /
    • 2002
  • Pharmacological ablation of the ciliary body by intravitreal injection of a cytotoxic dose of gentamicin was utilized for the treatment of absolute glaucoma in 13 dogs. Complications of this procedure were hyphema(2), corneal opacity(2), iris bombe(1), cataract(1) and chronic inflammation(1). Injection time was one time in 10 dogs, two times in 2 dogs and 3 times in a dog. Intravitreal injection of gentamicin was thought as a economic salvage procedure and has resulted in successful lowering of intraocular pressure.

A Clinical Study on Glaucoma (綠風에 對한 臨床的 考察)

  • Kim, Yoon-Bum;Chae, Byung-Yoon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.8 no.1
    • /
    • pp.143-147
    • /
    • 1995
  • We observed and studied about 14 cases of clinically glaucoma patients. Glaucoma is called NOK PUNG(綠風) in oriental medicine. Generally glaucoma patients, visiting oriental hospital, have a lower intraocular pressure than that of patients, visting western hospital. The weaksight and asthenopia were improved by acupunctural and Medicinal herbal therapy.

  • PDF

Changes in the Physiology of eye and Ocular function due to alcohol intake (알코올 섭취에 따른 눈의 생리기능과 안기능의 변화)

  • Lee, Jeung-Young;Seo, Jung-Ick;Park, Eun-Kyu
    • Journal of the Korea society of information convergence
    • /
    • v.7 no.2
    • /
    • pp.25-29
    • /
    • 2014
  • In this study, it examined the effects of alcohol on the physiology of the eye and ocular function. It was measured to IOP(intraocular pressure), tear secretion, stereoscopic parallax, AC A ratio, convergence ability, divergence ability alcohol intake before and after. The results were as follows. The mean IOP before alcohol intake 15.14mmHg and the mean IOP after alcohol intake 12.8mmHg. Average decreased 15.44%. The mean tear secretion before alcohol intake 17.125mm and the mean secretion after alcohol intake 9.875mm. Average decreased 42.33%. Stereoscopic parallax has increased by about four times that 40' before alcohol intake to 165' after that. AC/A ratio has increased by 14.6% that $5.40{\Delta}/D$ before alcohol intake to $6.19{\Delta}/D$ after that. Convergence and divergence ability was no significant change in both distance and close range.

  • PDF

Survey of Corneal Thickness, Endothelial Cell and Intraocular Pressure in New Zealand White Rabbits (뉴질랜드 흰 토끼의 각막 두께, 내피세포 및 안압에 관한 조사)

  • Chang, Hwa-Seok;Lee, Dae-Yeoup;Kang, Eun-Hee;Lee, Jae-Hoon;Cho, Yang-Kyeung;Kim, Man-Soo;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.411-414
    • /
    • 2010
  • Rabbit's cornea is the most common thing that used for researches in ophthalmology, so many experimentations have done. The purpose of this study was to survey the corneal pachymetry, tonometry and specular microscopy in New Zealand white rabbits. Three months old male rabbits ($2.9{\pm}0.2\;kg$) were examined with contact the specular microscope to evaluate the endothelial cell density, coefficiency of variation and the percentage of hexagonal cells in the central cornea. For the pachymetry, ultrasonic pachymeter was used for central cornea in each twenty rabbits, and tonometry was performed forty rabbit's eyes to evaluate the intraocular pressure. Corneal endothelial cell density in New Zealand white rabbit was $3304{\pm}354\;cell/mm^2$. Coefficiency of variation was $45.8{\pm}2$ and the percentage of hexagonal cells in the central cornea was $44.4{\pm}11%$. The pachymetry of cornea was $346.1{\pm}21\;{\mu}m$ and tonometry of eye was $14.3{\pm}2\;mmHg$. It is considered that normal New Zealand white rabbit's pachymetry, specular microscopy and tonometry were useful basic data of rabbit's cornea for research and clinic in veterinary ophthalmology.

A Frequency Domain Analysis of Corneal Deformation by Air Puff (Air puff에 의한 각막 변형의 주파수 영역 분석)

  • Hwang, Ho-Sik;Lee, Byeong Ha;Lee, Chang Su
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.240-247
    • /
    • 2014
  • Intraocular pressure is measured after a cornea air puff by observing biomechanical properties such as thickness or displacement of the cornea. In this paper, we deal with a frequency domain analysis of corneal deformation in the air puff tonometry that is used to diagnose glaucoma or lasik. We distinguish the patient from the normal by measuring the oscillation frequency in the neighborhood of the central cornea section. A binary image was obtained from the video images, and cornea vertical oscillation profile was extracted from the difference between the vertical displacement data and the curve fitting. In terms of Fourier transform, a vibration frequency of 479.2Hz for the patient was obtained as well as more higher 702.8Hz for the normal due to stiffness. Hilbert-Huang transform's empirical mode decomposition generally describes local, nonlinear, and nonstationary data. After the data were decomposed into intrinsic mode functions, a spectrum and power were analysed. Finally, we confirm that the patient has 6 times more higher power ratio for the specific intrinsic mode function between the patient and the normal.

Placement of an Intraocular Silicone Prosthesis with Evisceration in a Dog with Refractory Glaucoma (난치성 녹내장을 지닌 개에서 안구내용제거술을 통한 안구 내 실리콘 보철물 적용 1례)

  • Kim, Kyung-Hee;Kim, Joon-Young;Choi, Young-Min;Lee, Jong-Hoon;Park, Chang-Hee;Lee, Jung-Ha;Lee, Young-Sun;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.610-613
    • /
    • 2010
  • An 8-year-old male dog weighing 7.9 kg was referred to us for evaluation of exophthalmos and corneal edema of the left eye, on which cataract surgery had been performed 3 years prior. On ophthalmic examination, the left eye showed an extremely high intraocular pressure (47 mmHg), with no menace response, dazzle reflex, or pupillary light reflex. The dog was treated with systemic and topical glaucoma medications. After treatment, corneal edema decreased but IOP did not return to within acceptable limits. Seventeen months later, the dog presented with hyphema, episcleral congestion, and corneal edema attributable to accidental trauma. The owner wished to maintain an attractive ocular appearance, and an intraocular silicone prosthesis (ISP) was thus inserted after the evisceration. Three months postoperatively, a corneal ulcer was detected, but this resolved successfully after prescription of appropriate medication. One year after surgery, no complications related to surgery were evident.

Control of the Intraocular Pressure by Using the Micro Valve Actuator for a Glaucoma Implant

  • Byunghoon Bae;Park, Junhyun;Park, Kyihwan;Lee, Jonghyun;Lee, Yeon;Hongseok Kee;Kim, Seonho;Taeseok Sim;Kim, Yongkweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.74.6-74
    • /
    • 2002
  • $\textbullet$ A new implant capable of controlling IOP actively and coping with personal difference among patients $\textbullet$ The valve actuator of the active implant is proposed and fabricated. $\textbullet$ In vitro experiments are carried out extensively with and without a rabbit. $\textbullet$ The experiments are conducted by using the open and closed loop pressure control. $\textbullet$ The experiment with the rabbit is similar as a in vivo experiment, $\textbullet$ since the compliance and the aqueous humor of the rabbit's eye are included. $\textbullet$ The experimental results verify the possibility of the valve actuator for a glaucoma implant.

  • PDF