• Title/Summary/Keyword: Intra-motion

Search Result 211, Processing Time 0.026 seconds

Bitrate Adaptive Intra Refresh for MPEG-4 Video (MPEG-4 비디오에서의 비트율 적응 인트라 리프레쉬)

  • 금찬헌;최동환;황찬식
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.4
    • /
    • pp.23-30
    • /
    • 2004
  • In MPEG-4 video, Motion Adaptive Intra Refresh (MAIR) encodes a motion area macroblock in intra mode, thereby preventing the error propagation. Motion area is selected by difference of between current macroblock and previous macroblock. An effective implementation of the AIR is to reduce the maximum refresh time and estimate the error prone macroblock. However in the case or the MAIR, unnecessary macroblock can be encoded in intra mode. in this paper, a bitrate AIR is proposed that reduces the maximum refresh time by estimating the error prone macroblock more efficiently.

A Study on the Reliability and Validity of Measuring the Range of Motion of the Elbow Joint Using a Smartphone Application

  • Lee, Jun Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.

Digital Video Scrambling Methods using Motion Vector and Intra Prediction Mode (움직임 벡터와 인트라 예측 모드를 이용한 디지털 비디오 스크램블링 방법)

  • Ahn, Jin-Haeng;Jeon, Byeung-Woo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.133-142
    • /
    • 2005
  • In this paper, two digital video scrambling methods are proposed as simple means of the digital content protection techniques. One is inter block scrambling using motion vector, the other is intra block scrambling using intra prediction mode. The proposed inter block scrambling method distorts the original sequences by swapping horizontal and vertical components of motion vector. This method can be applied on most common video coding techniques such as MPEG-1, 2, 4, H.264, etc. The proposed intra block scrambling method distorts the original sequences by modifying intra prediction mode that is property of H.254 video coding technique. Both methods do not cause my bit rate increase after scrambling. Moreover, they have low complexity because they need only simple operation like XOR. Especially, the proposed intra block scrambling does not distort inter blocks directly. But inter blocks are distorted by error propagation effect as much as intra blocks. This paper introduces two new digital video scrambling method and verifies its effectiveness through simulation.

Reliability and Validity of Measurement Using Smartphone-Based Goniometer of Tibial External Rotation Angle in Standing Knee Flexion

  • Jeon, In-Cheol;Kwon, Oh-Yun;Weon, Jong-Hyuck;Ha, Sung-Min;Kim, Si-Hyun
    • Physical Therapy Korea
    • /
    • v.20 no.2
    • /
    • pp.60-68
    • /
    • 2013
  • The purpose of this study was to assess the intra-rater test-retest reliability of tibial external rotation angle measurement using a smartphone-based photographic goniometer, DrGoniometer (DrG) compared to a three-dimensional motion analysis system (Vicon). The current study showed an interchangeable method using DrG to measure the tibial external rotation angle in standing knee flexion at $90^{\circ}$. Twelve healthy subjects participated in this study. A rest session was conducted 30 minutes later for within-day reliability and five days later for between-day intra-rater test-retest reliability. To assess the validity of the measurement using DrG, we used a three dimensional motion analysis system as a gold standard to measure the angle of tibial external rotation. Intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) values were used to determine the within- and between- day intra-rater test-retest reliability of using DrG and a three dimensional motion analysis system. To assess validity, Pearson correlation coefficients were used for two measurement techniques. The measurement for tibial external rotation had high intra-rater test-retest reliability of within-day (ICC=.88) and between-day (ICC=.83) reliability using DrG and of within-day (ICC=.93) and between-day (ICC=.77) reliability using a three-dimentional motion analysis system. Tibial external rotation angle measurement using DrG was highly correlated with those of the three-dimensional motion analysis system (r=.86). These results represented that the tibial external rotation angle measurement using DrG showed acceptable reliability and validity compared with the use of three-dimensional motion analysis system.

Reliability of the Joint Neutral Position and Measurement Methods of the Ankle Joint Complex Range of Motion (발목관절 복합체의 가동범위 측정을 위한 중립위치와 측정방법의 신뢰도)

  • Hong, Wan-Sung;Kim, Gi-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.4
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: To determine the correct measurement methods of the ankle joint complex range of motion for measuring the neutral position and evaluate the rater reliability. In addition, the impact of training on the rater reliability was also assessed. Methods: The subjects were eleven healthy women, who were evaluated by two physical therapists and one physical therapist recorded the results of the study. Standard goniometer was used as the measurement tool. The ankle and subtalar joint neutral position and the active range of motion of the ankle and subtalar joint were measured. Intra-rater reliability and inter-rater reliability measures were analyzed with intraclass correlation coefficients. Results: Intra-rater reliability and inter-rater reliability ranged from high to medium for the neutral position of the ankle joint complex. Intra-rater reliability for dorsiflexion and plantarflexion measurements was medium, while the inter-rater reliability was high. The range of motion of the subtalar joint was measured, and the intra-rater reliability and inter-rater reliability were low and medium, respectively Also, the intra-rater reliability was increased with formal training of the measurement techniques. Intra-rater reliability was reduced in case the raters had not undertaken the training. Conclusion: In summary, the results obtained with the measurement tools and joint measurement of position, indicate the consistency of repeated measurements made by the same observers. Under the same circumstances along with repetition of the same measurement technique during training caused an increase in the rater reliability of formally trained raters.

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.22 no.4
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

Design of Memory-Access-Efficient H.264 Intra Predictor Integrated with Motion Compensator (H.264 복호기에서 움직임 보상기와 연계하여 메모리 접근면에서 효율적인 인트라 예측기 설계)

  • Park, Jong-Sik;Lee, Seong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.37-42
    • /
    • 2008
  • In H.264/AVC decoder, intra predictor, motion compensator, and deblocking filter need to read reference images in external frame memory in decoding process. They read external frame memory very frequently, which lowers system operation speed and increases power consumption. This paper proposes a intra predictor integrated with motion compensator without external frame memory. It achieves power reduction and memory bandwidth minimization by exploiting data reuse of common and repetitive pixels. The proposed infra predictor achieves more than $45%\;{\sim}\;75%$ cycle time reduction compared with conventional intra predictors.

Arthroscopic Excision of Delayed Diagnosed Intra-articular Osteoid Osteoma of the Elbow: A Case Report

  • Park, Sam Guk;Shin, Duk Seop;Choi, Joon Hyuk;Na, Ho Dong;Park, Jae Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.3
    • /
    • pp.162-168
    • /
    • 2018
  • An intra-articular osteoid osteoma is a very rare cause of elbow pain, and its diagnosis and treatment remain challenging. Delayed diagnosis may lead to arthritic change of the joint. In this study, the authors present the occurrence of intra-articular osteoid osteoma in the right elbow of a 15-year-old male patient who presented with prolonged pain and limited motion owing to delayed diagnosis. After confirming the nidus of osteoid osteoma from radiographic evaluation, the lesion was completely removed arthroscopically. The patient presented a complete relief of symptoms and full range of motion. This is the first domestic report of successful arthroscopic treatment of an intra-articular osteoid osteoma of the elbow.

Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke (뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구)

  • Park, Il-Woo;Lim, One-Bin;Park, Kyue-Nam;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

An investigation Of IntraFraction Motion Correction For Lung Stereotactic Body Radiation Therapy By Using IntraFraction Cone Beam Computed Tomography (폐암 환자의 정위적 체부 방사선 치료 시 IntraFraction CBCT를 이용한 치료 중 자세 오차 교정에 대한 고찰)

  • Song, Hyeong Seok;Cho, Kang Chul;Park, Hyo Kuk;Yoon, Jong Won;Cho, Jung Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Purpose: The purpose is to correct for position errors caused by long treatment times. By correcting the target motion that can occur during lung SBRT using IntraFraction CBCT. Methods and materials: We analyzed retrospectively the IFM data of 14 patients with two treatment arc in the treatment plan for lung cancer with stereotactic radiotherapy. An IntraFraction Motion was applied to the Arccheck phantom to acquire the Gamma index data. Results : IntraFraction Motion during the first treatment arc is in the left-right(LR), superiorinferior(SI), anterior-posterior(AP) directions were $0.16{\pm}0.05cm$, 0.72 cm(max error), $0.2{\pm}0.14cm$, 1.26 cm, $0.24{\pm}0.08cm$, 0.82 cm and rotational directions was $0.84{\pm}0.23^{\circ}$, $2.8^{\circ}$(pitch), $0.72{\pm}0.23^{\circ}$, $2.5^{\circ}$(yaw), $0.7{\pm}0.19^{\circ}$, $2^{\circ}$(roll). IntraFraction Motion during the second treatment arc is in the LR, SI, AP directions were $0.1{\pm}0.04cm$, 0.37 cm, $0.14{\pm}0.17cm$, 2 cm, $0.12{\pm}0.04cm$, 0.5 cm and rotational directions was $0.45{\pm}0.12^{\circ}$, $1.3^{\circ}$, $0.37{\pm}0.1^{\circ}$, $1^{\circ}$, $0.35{\pm}0.1^{\circ}$, $1.2^{\circ}$. Gamma index pass rates were $82.64{\pm}10.51%$, 48.4 %. Conclusions : In this study, we examined the validity of IntraFraction Motion correction in lung SBRT and the efficiency of IntraFraction CBCT. Due to the nature of SBRT treatment, IFM may increase due to the increased treatment time. It is believed that the increase in IFM with the increase in treatment time can be improved with the use of FFF Beam and additional position correction using CBCT during treatment.