• Title/Summary/Keyword: International temperature scale of 1990

Search Result 6, Processing Time 0.021 seconds

Intralaboratory Comparison of the Realization of the Triple-point Temperature of Mercury (수은 삼중점 온도 실현의 교정 기관 내 비교)

  • Inseok, Yang;Young Hee, Lee
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.448-454
    • /
    • 2022
  • An intralaboratory comparison of the realization of the triple-point temperature of mercury, which is defined as -38.8344℃ on the international temperature scale of 1990 (ITS-90), was conducted at the Korea Research Institute of Standards and Science (KRISS), the national metrology institute of Korea. To this end, four triple-point-of-mercury cells were compared using the resistance ratio measurement of a standard platinum resistance thermometer to validate the calibration results obtained using the triple-point-of-mercury cells at KRISS. The triple-point temperatures of all the four cells, one of which is designated as the national standard cell, were within 0.3 mK of the national standard. Based on 13 experiments on the four triple-point-of-mercury cells, the uncertainty in the comparison of the triple-point-of-mercury cells was 0.08 mK, and the uncertainty in the realization of the triple-point temperature of mercury was 0.19 mK. The results of the intralaboratory comparison validated that utilizing any of the four triple-point-of-mercury cells would result in the realization of a temperature within 0.3 mK of the average value determined by two key international comparisons for the realization of -38.3844℃ following the ITS-90.

Measurement of triple point of water temperature for improvement of the national standards and key comparison (국가표준향상과 핵심국제비교를 위한 물의 삼중점 온도 측정)

  • Yang, Inseok;Lee, Young Hee
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.349-356
    • /
    • 2021
  • The Korea Research Institute of Standards and Science (KRISS), a National Metrology Institute of Korea, participated in the second-round of the international key comparison CCT-K7.2021 of triple point of water (TPW) cells. For the key comparison, three TPW cells, one of which had been used in the old CCT-K7 comparison, were assigned as the national standard of the TPW. The temperature difference (ΔT) between the average of the new and old national standards and ΔT between the new national standard and the transfer standard were measured. The comparison between the new and old national standards indicated a temperature increase of 69.5 µK after both the standards were corrected for the isotopic composition. The uncertainty of the national standard of the TPW temperature was 28 µK, and the uncertainty of ΔT was 14 µK. Three aspects of improvements in the new comparison compared to the old one were noted: (1) inclusion of two quartz cells in the national standard strengthens its long-term stability; (2) the standard deviation associated with the measurement of ΔT was reduced from 21 µK to 9.6 µK; (3) and the measured immersion profile of the TPW cells was much closer to the theoretically predicted dependence.

Realization of Triple Point of Ne, $O_2$, Ar, Hg and $H_2O$ for International Comparison of Capsule-type Platinum Resistance Thermometer (캡슐형 백금저항온도계 국제비교를 위한 네온, 산소, 아르곤, 수은 및 물의 삼중점 실현)

  • Kang, Kee-Hoon;Kim, Yong-Gyoo;Gam, Kee-Sool
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.153-162
    • /
    • 2000
  • Triple points of high purity materials have been used to calibrate primarily the capsule-type platinum resistance thermometer (PRT) in the temperature range of the triple point of equilibrium hydrogen (13.8033 K) and water (273.16 K). In this work, triple points of Ne, $O_2$, Ar, Hg and $H_2O$ except for the triple point of equilibrium hydrogen were realized to establish the International Temperature Scale of 1990 (ITS-90). At each fixed point, two capsule-type PRTs, which were selected for the international comparison, were tested two times. The combined uncertainties of the realization of each triple point were calculated considering the type A and type B evaluation. In Korea Research Institute of Standards and Science, the combined standard uncertainties of the defining triple Points by the ITS-90 were estimated to about 0.18 mK for Ne, 0.14 mK for $O_2$, 0.14 mK for Ar, 0.24 mK for Hg and 0.11 mK for $H_2O$, respectively.

  • PDF

Realization of silver fixed-point and application for the high temperature platinum resistance thermometry using the gas-pressure controlled sodium heat-pipe furnace (가스압력조절식 나트륨 열관전기로를 이용한 은 고정점 실현과 고온백금저항온도 계측에의 응용)

  • Gam, K.S.;Choi, I.M.;Yang, I.;Kim, Y.G.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Pressure-controlled sodium heat pipe furnace was designed and fabricated, and its characteristics was investigated. Pressure control system was controlled within ${\pm}0.5\;Pa$ at 150 kPa and the stability of pressure was decreased to ${\pm}2.5\;Pa$, when the pressure-controlled system connected with the heat pipe. The melting curve of Ag fixed-point realized well by the adiabatic method using the pressure-controlled sodium heat pipe furnace and its accuracy showed ${\pm}2.27\;mK$ from the calculation of 20% to 80% at the plateau. The freezing curve of Ag fixed-point also realized and its plateau value was 2.23 mK lower than that of the melting curve.

Evaluation of Uncertainty Sources in Temperature Measurement Using Platinum Resistance Thermometer Caused by Temperature Gradient in Furnace and Sealed-type Freezing Point Cells (전기로 및 봉입형 응고점 셀 내의 온도구배가 미치는 표준백금저항온도계 온도측정의 불확도 요소 평가)

  • Kang, Kee-Hoon;Gam, Kee-Sool;Kim, Yong-Gyoo;Song, Chang-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.411-416
    • /
    • 2004
  • In the international temperature scale of 1990 (ITS-90), standard platinum resistance thermometer (SPRT) is a defining standard thermometer used in the temperature range from 13.8033 K to $961^{\circ}C$. Uncertainty of SPRT is about several mK and uncertainty of defining fixed points of the ITS-90 which is used for calibrating SPRT is about several tenth of mK. Above $0^{\circ}C$. the defining fixed points are gallium melting point and indium, tin, zinc, aluminium and silver freezing points which are all realized using an electric furnace or a liquid bath. To realize freezing point of tin ($231.928^{\circ}C$) and zinc ($419.527^{\cir}C$), two 3-zone furnaces which have 3 electric heaters were manufactured. Temperature gradient of the constructed furnaces were tested. Uncertainty caused by temperature gradient of furnace and immersion effect of SPRT in the sealed-type freezing point cells were evaluated 0.038 mK for tin freezing point and 0.036 mK for zinc freezing point.

An Approach for Enhancing Current Korean e-Grocery Business Focusing on Delivery Service Alternatives (한국의 e-Grocery 배송서비스 대안에 관한 연구)

  • Koo, Jong-Soon;Lee, Jung-Sun;Jeon, Dong-Hwa
    • International Commerce and Information Review
    • /
    • v.13 no.3
    • /
    • pp.169-201
    • /
    • 2011
  • There was a new wave in grocery business with development of information and technology, thus a movement from traditional stores to online stores, In order to expand the scale of traditional supermarket and to satisfy the customers' needs, they provide offline and online services simultaneously. This paper is based on the previous studies which had been researched in developed countries from late 1990s to early 2000s and the purpose of this study is to introduce the idea and operation system of e-Grocery business. Moreover, we suggest the alternatives on delivery service methods in order to satisfy the customers' needs through analyzing the current condition of e-Grocers in Korea. According to the result of this study, Korean e-Grocers offer only attended home delivery services. In our opinion, Korean supermarkets have to take hybrid model which Tesco.com is using. There are some alternatives to increase the profits of Korean e-Grocers and to provide better services to their customers as follows: As an alternatives for delivery services, picking service is the easiest and cheapest way to apply for supermarkets. This is very useful for working women and also it is possible to order by smartphone recently. They can order the goods to the closest local supermarkets from working place, and then they pick them up on the way home from working off. In order to improve the quality of delivery services, to use the reception box will be the way to provide better services to the customers. The reception box is a way to protect the quality of goods such as fresh-cut product, which require the freshness through the temperature adjustment, and also to keep the safety of ordered goods through locking system Through this system, supermarkets are able to use attended or unattended services under the customers' satisfaction. However, using the reception box is expensive, so shared reception box will be an alternative. As an alternative for development of e-Grocery business, the advertisement for e-Grocery business has to be supported in order to attract potential customers in e-Grocery business. Furthermore, the main concerns of e-Grocery business such as the sanitation and safety of goods, and convenience must be guaranteed in order to keep the loyal customers and to attract new customers.

  • PDF