• Title/Summary/Keyword: International System of Units

Search Result 196, Processing Time 0.02 seconds

A Study of International Standardization of the International System of Units (SI) for Safe Operation of Aircrafts (항공기 운항안전을 위한 SI의 국제표준 통일안 연구)

  • Lee, Gang-Hyeon;Choi, Sung-Ho;Lee, Yeong-Heok;Kim, Young-Mi
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.22 no.4
    • /
    • pp.87-92
    • /
    • 2014
  • In spite of ICAO's effort to ensure the safety of flight operation by requiring crews, controllers, and other ground aviation staffs to use unified system for units, SI (System International of units), there are still many aircrafts designed, manufactured, and operated based on non-SI units, and many crew training in airline companies are also conducted based on non-SI. Due to this confusion of using different unit systems in international flight operation, many crew members and passengers are exposed to danger. International flights pilots may have confusion while flying different airspaces of different countries that use different unit systems, and this may cause human errors causing accidents and incidents. Due to these reasons, it is needed to establish the standards to reflect non-SI that many countries practically use to SI, which is international standard.

A Guide to Education on Unit Transformation in University Liberal Arts Education (대학 교양교육에서 단위변환에 대한 교육 방향 제시)

  • kyung a jeong;hye jeong kim
    • Journal of Integrative Natural Science
    • /
    • v.16 no.4
    • /
    • pp.133-138
    • /
    • 2023
  • After the SI system of units was adopted as an international system of units, Korea made a lot of efforts such as administrative and educational guidance on the traditional units that had been used so far. In addition, from July 1, 2007, the government has cracked down on the denotation of non-statutory units of measurement as standard units or auxiliary units in commercial transactions. However, non-statutory weighing units are still used in other forms. It is believed that this is because non-statutory units (= our traditional units) are permeated in our lives and are convenient to use. The general public still finds it difficult to use and mark the SI system of units correctly. This is not a problem unique to Korea. However, if you look at the books that are currently used as university physics textbooks, the SI system of units and the non-legal units of other countries are marked in such a way that they can be accurately converted. Only the traditional units of our country are disappearing under the pretext of unit unification. Accordingly, we propose that our units should not be neglected in university education, but should be labeled together. The purpose of this study is to raise the necessity of reorganizing the unit conversion between the SI unit system and the traditional life improvement unit, which continues to be the convenience of life, and applying it in university physics education to enable the conversion with our traditional unit, and to educate the importance of the meaning and function of our traditional unit.

The Preservice Teachers등 Understanding of the International System of Units (국제단위제도에 대한 초등학교 예비 교사들의 이해)

  • 김성규;김윤경
    • Journal of Korean Elementary Science Education
    • /
    • v.23 no.1
    • /
    • pp.27-36
    • /
    • 2004
  • This paper aims to examine how well university students, who are going to be primary school teachers, understand the International System of Units (SI), focusing on seven basic units such as 'm', '㎏', '㏖', 'A', 'K', 's', 'cd'. This study specifically investigates whether the students know the seven units and understand their uses and how they read and learn them. The subjects were 1030 students from the University of Education in Jinju, Geongsangnamdo. Data was collected through a questionnaire which was designed by this researcher and checked by an authority, and the frequency and percentage of reponses to each question were obtained and analysed. Findings show all the students knew very well that 'm' and '㎏' are included in the seven units, compared to the others which low percentage of the students considered as the elements. In terms of understanding of use, the units of the length 'm', the mass '㎏', and the time 's' are well understood, presumably, because they are often used in ordinary life and school, while the amount of substance '㏖', the electric current 'A', the thermodynamic temperature 'K', and the luminous intensity 'cd' are not as well understood. It is probably because 'A', 'cd', and 'K' are hardly used in everyday life. With respect to reading the units, the subjects read 'm', '㎏', '㏖', and's' much better than the others. As for the source of learning them, most students answered they learned them in schools, which implies school education is very important. From these results it is concluded that school education should be accompanied with use in everyday life for understanding and using the units. SI Base Units understanding was investigated by an academic year. According to this investigation, generally the right answer rate differed 4<2<3<1 by an academic year in order. For the Senior, Sophomore appeared the right answer rate more high. because, they learned before in deepening or elementary course on chemistry and physics related with SI Base Units. On the other hand, for the junior answered low rate by this reason that they couldn't remember about SI Base Units that learned before. For the Freshman appeared low rate by this reason that they were not learned or graduated from the department of liberal art in high school.

  • PDF

Component Specification of Physical Measurement Units in Web3D (웹3D에서의 물리적 측정 단위 컴포넌트 명세)

  • Kim, Su-Hyun;Lee, Myeong-Won
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.6
    • /
    • pp.454-458
    • /
    • 2009
  • The technology of virtual environments has been developed with better-quality appearance on a computer display in mind, but without consideration for objects' precise measurements in physical units. With the increased application of computer graphics in a variety of areas, there is a need for precise measurement functionality in addition to visualization. This paper describes the definition of physical properties using measurement units for X3D based virtual objects, to provide their precise physical information in virtual environments. To this end, we have included the physical property node in the X3D specification. The physical measurement units, such as length, mass, time, temperature, etc., are based on SI units (International System of Units).

Schema Definition and Implementation for Web3D Physical Units (웹3D 물리 단위 스키마 정의와 구현)

  • Kim, Lee-Hyun;Park, Chang-Sup;Lee, Myeong-Won
    • Journal of the Korea Computer Graphics Society
    • /
    • v.16 no.3
    • /
    • pp.11-19
    • /
    • 2010
  • This paper describes how to define and implement the schema for 3D virtual objects with physical units so that the objects can be compared in virtual environments based on physical properties, such as length, according to the specified units. We define physical units for virtual objects using the International System of Units and based on the X3D (Extensible 3D) specification. The schema must be defined with validation so that it does not violate the original X3D data structure. In this paper, we have extended the original X3D schema with a physical unit specification, and demonstrate the difference between units-specified and non-units-specified 3D scenes using an X3D browser that we developed.

Implementation of Drug Delivery Constitution for Inpatient based on the Position Tracking System

  • Kim, Jeong-lae;Yoon, Su-yeon;Gil, Sang-hee;Park, Bo-geun;Jeong, Hyun-woo
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.402-408
    • /
    • 2021
  • We are designed the delivery constitution technique that is to be measure the safe RFID statusof thewireless delivery system level (WDSL) on the delivery system tracking system. The delivery system level condition by the delivery system tracking system is organized with the RFID system. As to inspection a wireless network of the wireless network, we are found of the delivery value with wireless network by the upper take form. The concept of delivery system level is organized the reference of wireless level for delivery signal by the delivery RFID tracking system. Further, symbolizing a safe deliveryof the WDSL of the medium-minimum interval of the RFID tracking system, and the delivery wireless network RFID that was the delivery value of the far delivery of the DSTS-FA-φMED-MIN with 5.80±1.20 units, that was the delivery value of the convenient delivery of the DSTS-CO-φMED-MIN with 4.06±(-0.04) units, that was the delivery value of the flank delivery of the DSTS-φMED-MIN with 0.91±0.07 units, that was the delivery value of the vicinage delivery of the DSTS-VI-φMED-MIN with 0.18±(-0.03) units. The RFID will be to look into at the safe of the RFID tracking systemwith wireless network bythe delivery system level on the WDSL that is supply the wireless tracking system by the delivery system level system. We will be possible make to curb of a tracking system that to put the wireless signal and to use of the delivery data of RFID level by the delivery system.

Study of Modeling for Stock Food Material with Location Movement by the Communication Signal System

  • Kim, Jeong-Lae;Kim, Jung-Yun;Rha, Young-Ah
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.409-416
    • /
    • 2021
  • We are invented the movement composition technique that is to check the food adjacent-package status of the wireless-management movement monitoring level (WMMML) on the movement monitoring communication system. The movement monitoring level condition by the movement monitoring communication system is formatted with the adjacent-package system. As to inspection a wireless RFID of the wireless RFID, we are found of the movement value with wireless RFID by the adjacent upper take form. The concept of movement monitoring level is formatted the reference of wireless-management level for composition signal by the movement package communication system. Further symbolizing a food composition of the WMMML of the medium-minimum in terms of the adjacent-package communication system, and the movement wireless RFID package that was the movement value of the far composition of the Mo-MMCS-FA-φMED-MIN with 5.80±1.20 units, that was the movement value of the convenient composition of the Mo-MMCS-CO-φMED-MIN with 4.06±(-0.04) units, that was the movement value of the flank composition of the Mo-MMCS-MO-φMED-MIN with 0.91±0.07 units, that was the movement value of the vicinage composition of the Mo-MMCS-VI-φMED-MIN with 0.18±(-0.03) units. The adjacent package will be to look into at the food ability of the adjacent-package communication system with wireless RFID by the movement monitoring level on the WMMML that is supply the wireless communication by the movement monitoring level system. We will be possible to make effort of a communication system by the management signal and to put to use of the delivery data of RFID level by the delivery system.

A Study on Reliability Improvement of Domestic Ground Source Heat Pump Units by Analyzing the Certification System (국내 지열원 히트펌프 유닛의 인증제도 분석을 통한 신뢰성 향상 방안 연구)

  • Chan Woo Yang;Hee Jeong Kang;Sewang Oh;Ubin Do;Kwang Ho Lee;Jong Woong Choi;Yong Cho;Jong Min Choi
    • New & Renewable Energy
    • /
    • v.19 no.4
    • /
    • pp.72-83
    • /
    • 2023
  • Only ground source heat pump units certified according to the regulations in Korea can be adopted in ground source heat pump systems. In this study, domestic and international standards and regulations for ground source heat pump units were investigated. Unlike ISO 13256-1~2, which is the international standard, KS B 8292~8294 for ground source heat pump unit only included rated test conditions. Therefore, it is necessary to supplement various test conditions to the KS B series, because its performance data, which is required to calculate the system's design capacity, is dependent on the change in entering water temperature. The difference between the coefficient of performance of the certified ground source heat pump units and the certified criteria changed significantly according to the operating mode, heat source, and load type, because the criteria increased by about 5% for all. Thus, it is highly suggested that the certification standards be revised while considering the product performance level and various conditions.