• Title/Summary/Keyword: Internal wind flow

Search Result 72, Processing Time 0.018 seconds

Numerical Interpolation on the Simulation of Air Flow Field and the Effect of Data Quality Control in Complex Terrain (객관 분석에 의한 복잡지형의 대기유동장 수치모의와 모델에 의한 자료질 조절효과)

  • Lee Hwa woon;Choi Hyun-Jung;Lee Kang-Yoel
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.97-105
    • /
    • 2005
  • In order to reduce the uncertainties and improve the air flow field, objective analysis using asynoptic observational data is chosen as a method that enhances the reality of meteorology. In surficial data and their numerical interpolation for improving the interpretation of meteorological components, objective analysis scheme should perform a smooth interpolation, detect and remove the bad data and carry out internal consistency analysis. For objective analysis technique which related to data reliability and error suppression, we carried out two quality control methods. In site quality control, asynoptic observational data at urban area revealed low representation by the complex terrain and buildings. In case of wind field, it was more effective than temperature field when it were interpolated near waterbody data. Many roads, buildings, subways, vehicles are bring about artificial heat which left out of consideration on the simulation of air flow field. Therefore, in temperature field, objective analysis for more effective result was obtained when surficial data were interpolated as many as possible using value quality control rather than the selection of representative site.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.