• 제목/요약/키워드: Internal transducer probe

검색결과 3건 처리시간 0.017초

유도초음파를 이용한 복수기 튜브지지판 영역에서의 결함검출기법 (A Technique for Defect Detection of Condenser Tube in Support Plate Region using Guided Wave)

  • 김용권;박익근;박세준;안연식;길두송
    • Journal of Welding and Joining
    • /
    • 제30권6호
    • /
    • pp.36-41
    • /
    • 2012
  • General condensers consist of many tubes supported by tube sheets and support plates to prevent the deflection of the condenser tubes. When a fluid at high pressure and temperature runs over the tubes for the purpose of transferring heat from one medium to another, the tubes vibrate and their surface comes into contact with the support plates. This vibration causes damage to the tubes, such as cracks and wear. We propose an ultrasonic guided wave technique to detect the above problems in the support plate region. In the proposed method, the ultrasonic guided wave mode, L(0,1), is excited using an internal transducer probe from a single position at the end of the tube. In this paper, we present a preliminary experimental verification using a super stainless tube and show that the defects can be discriminated from the support signals in the support region.

수직관에서 2상선회유동이 보이드분포와 압력강하에 미치는 영향 (The Effects of Two - Phase Swirling Flow on Void Distribution and Pressure Drop in a Vertical Tube)

  • 김인석;손병진;신현동;곽기태
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.190-201
    • /
    • 1989
  • This experimental investigation has been conducted to determine the effects of swirling angle and flow patterns on distributions of void fraction, bubble velocity and two-phase pressure drop in a vertical straight tube. Swirling angles of $0^{\circ}$ (non swirling), $30^{\circ}$, and $45^{\circ}$ were tested with air-water two components over a range of superficial air velocities. A transparent lucite tube of 38mm in internal diameter was used for the test section. The void fraction and bubble velocities were measured by means of a optical fiber probe at the upper part of the swirler in the test section. Pressure drops which seem to be closely related with flow patterns and swirling angle were measured by a differential pressure transducer. It is shown that the probability density functions of pressure drop demonstrate peculiar features for both swirling angles and flow patterns, whereas the distributions of void fraction and bubble velocities are parabolic and flat shape in the vicinity of tube center, respectively except bubbly flow in any swirling angle cases, and the void fraction increases with increasing swirling angle around the center of tube.

  • PDF

만성폐쇄성 폐질환 환자에서 M-mode 초음파로 측정한 횡격막 운동 (M-mode Ultrasound Assessment of Diaphragmatic Excursions in Chronic Obstructive Pulmonary Disease : Relation to Pulmonary Function Test and Mouth Pressure)

  • 임성철;장일권;박형관;황준화;강유호;김영철;박경욱
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권4호
    • /
    • pp.736-745
    • /
    • 1998
  • 연구배경: 횡격막의 운동은 흉부 단순 촬영과 fluoroscopy로 관찰해 왔으나 근래 초음파에 의해서 횡격막의 운동거리와 두께를 측정하는 연구들이 있어왔다. 초음파 검사의 장점을 살펴보면 간편하고 비침습적이며 방사선조사가 없고 재현성과 정확성이 있다는 점을 들 수 있다. 본 연구에서는 이러한 횡격막 운동 측정에 대한 초음파의 장점을 이용하여 정상인과 만성폐쇄성 폐질환 환자에서 횡격막 운동을 조사하고 그 결과를 폐기능 지표들과 비교하였다. 연구방법: 정상 성인 28례(의과대학생 16례, 나이를 고려한 대조군 12례)와 만성폐쇄성 폐질환 환자 17례를 대상으로 각각에서 폐기능 검사, 최대 흡기압, 최대 호기압과 초음파상 횡격막의 이동 거리를 측정하여 비교하였다. 초음파는 Aloka 사의 KEC-620 모델을 이용하였으며 앙와위 상태에서 환자의 쇄골 중심선에 해당하는 부위의 우상복부에 횡으로 3.5MHz 탐촉자를 대고 간을 에코창으로 이용하여 M-mode 상에서 평상 호흡시와 폐활량 호흡 또는 최대 호흡시의 횡격막 이동 거리를 3회 측정하여 그 평균값을 얻었으며 최대 흡기압과 최대호기압은 Chest사의 Vitalopower KH-101을 이용하여 3회 측정하여 그 평균값을 얻었다. 결 과: 정상인에서의 횡격막 이동거리는 평상호흡에는 1.5cm-1.7cm를 보였고 최대호흡시에는 5.7cm-6.7cm를 보였다. 정상인에서의 최대호흡시에 횡격막 이동거리는 $FEV_1$ $FEV_1/FVC$, PEF, PIF, 신장과 유의한 상관관계를 보였으나 다중 희귀분석에서는 $FEV_1$ 만이 유용한 예측지표로 계산되었다. 만성폐쇄성 폐질환 환자에서의 횡격막 이용거리는 평상호흡시에는 $1.5{\pm}0.6cm$로 정상인과 유의한 차이가 없었으나 최대호흡시에는 $3.7{\pm}1.3cm$로 대조군에 비해 유의하게 감소되어 있었다. 만성폐쇄성 폐질환 환자군의 각 병기에 따라 횡격막 이동거리를 비교해 본 결과 최대호흡시 횡격막의 이동거리는 $FEV_1$이 감소할수록 짧은 경향을 보였으나 통계적 의의는 없었다. 만성폐쇄성 폐질환 환자에서의 최대호흡시에 횡격막 이동거리는 연령, PEmax, %FVC와 유의한 상관관계를 보였으나 다중 회귀분석에서는 최대호기압(PEmax)과 연령이 유의한 예측인자로 계산되었다. 결 론: 만성폐쇄성 폐질환 환자의 횡격막 이동거리는 정상인에 비해 유의하게 감소하였으며 최대호기압과 가장 좋은 상관관계를 보였다. 그러나 만성폐쇄성 폐질환 환자에서 횡격막 이동거리는 $FEV_1$과 유의한 상관관계를 발견할 수 없어서 초음파를 통한 횡격막 운동검사가 폐기능 평가의 또다른 생리적 지표로 이용될 수 있음을 시사하였다.

  • PDF