• 제목/요약/키워드: Internal radiation dose

검색결과 332건 처리시간 0.03초

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • 제47권4호
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

호흡주기에 따른 방사선입체조형치료법의 개발 (Development of Conformal Radiotherapy with Respiratory Gate Device)

  • 추성실;조광환;이창걸;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.41-52
    • /
    • 2002
  • 목적 : 호흡주기에 따른 위치변동 감지센서를 이용하여 종양의 위치가 일정워치에 있을 때만 방사선을 치료하는 호흡 동기치료기구를 제작하고 일정한 호흡주기 상태에서 수행된 CT simulation과 3차원 입체조형치료계획에 따라 방사선을 치료하는 시스템을 개발하고자 하였다. 호흡유무에 따른 종양의 치료 마진(margin)을 측정하고 계획용표적체적(planning target volume:PTV)의 크기에 따른 선량체적표(dose volume histogram:DVH)와 종양억제확률(tumor control probability:NTCP), 건강조직손상확률(normal tissue complication probability:NTCP) 및 선량 통계자료를 통하여 치료성과를 평가하고 선량증강 범위를 예측하고자 하였다. 대상 및 방법 : 종양이 비교적 작고 전이가 없는(T1N0M0) 5명의 폐암환자를 선택하여 X-선 조준장치를 이용하여 횡격막의 이동거리를 측정하는 방법으로 내부장기의 운동을 평가하였다. 호흡동기치료기구는 끌어당김 센서가 부착된 허리띠 모양으로 구성되었으며 이를 흉곽 또는 복부에 부착하여 호흡주기에 의한 흉곽의 크기변동에 따라 센서의 회로가 개폐되고 이것을 선형가속기의 조종간에 연결하는 간단한 기구로서 감도와 재현성이 높았다. 호흡을 배기한 후 일시적 호흡이 정지된 상태에서 Spiral-CT (PQ-5000)로 3차원 영상을 획득하고 Virtual CT-simulator (AcQ-SIM)에 의하여 종양의 위치와 주위 장기들을 확인 도시하였으며 3차원 치료계획장치(Pinnacle, ADAC Co.)를 이용하여 3차원 입체조형치료를 계획하였다. 치료계획의 평가는 호흡동기치료기구의 사용유무에 따른 PTV의 크기에 따라 최적 선량분포를 구사하였으며 각각의 DVH, TCP, NTCP 및 선량통계자료를 도출 비교 검토하였다. 결과 : X-선 simulation에서 폐암환자의 횡격막 이동은 약 1 cm에서 2.5 cm로서 평균 1.5 cm로 측정되었고 자유호흡시 PTV는 CTV (clinical target volume)에 약 2 cm 마진을 주었으며 호흡동기치료기구를 사용하였을 때는 0.5 cm 마진이 적당한 것으로 측정되었다. 종양의 PTV는 연장 마진의 거의 자승비로 증가하였으며 TCP의 값은 마진 범위 $(0.5\~2.0\;cm)$에 관계없이 거의 일정하였고 NTCP의 값은 마진 크기에 따라 평균 $65\%$로 급속히 증가하였다. 결론 : 호흡주기에 따른 위치변동 감지센서를 이용한 호흡동기치료기구는 종양의 위치가 일정할 때만 방사선이 조사되는 간단하고 정확한 장치로서 3차원 입체조형치료 및 강도변조방사선치료에서 매우 유용한 장치임을 확인할 수 있었다. 또한 호흡조절 방사선입체조형치료방법의 기술과 시술절차를 확립시키고 정량적인 선량평가를 위하여 DVH, TCP, NTCP 등의 정량분석과 종양의 투여 선량 증가량(dose escalation)을 예측하는 기초자료를 제공할 수 있었다.

Stent-assisted Angioplasty for Symptomatic Radiation-induced Carotid Stenosis

  • Kwon, Yoon-Kwang;Kim, Eal-Maan;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권5호
    • /
    • pp.327-329
    • /
    • 2007
  • A 44-year-old woman presented with recurrent, transient episodes of left-side hemiparesis. She had received a radiation dose of 6120 cGy to her cervical region for parotid gland carcinoma 13 years previously. Cerebral angiography revealed a long, irregular tight stenosis involving the right extracranial internal carotid artery [ICA] and common carotid artery [CCA], measuring approximately 90% at the most severe narrowing according to North American Symptomatic Carotid Endarterectomy Trial criteria. Endovascular stent placement resulted in restoration of the carotid lumen to about 80% of its original diameter. She showed no further ischemic events during the follow-up period of 48 months. Our clinical and angiographic findings suggest that carotid stenting is considered a safe and effective treatment option in patients with radiation-induced carotid stenosis.

갑상선 내부피폭선량 측정치 보정을 위한 몬테카를로 모의실험 코드 (CALEFF) 개발 및 검출효율 계산 (Development of a Monte Carlo Simulation Code (CALEFF) for Calibrating Thyroid Internal Dose Measurement and Detection Efficiency Calculation)

  • 안기수;조효성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권2호
    • /
    • pp.117-122
    • /
    • 2005
  • 1999년 개정된 국내 원자력법 시행령 제2조 5항에 의하면 2003년부터 원전 작업종사자들에 대해 외부 피폭 선량뿐만 아니라 내부피폭 선량도 합산하여 평가하도록 하였으며 또한 각 선량평가에 대한 오차도 50% 이내로 유지되어야 한다고 규정한 바 있어 전신이나 갑상선 계측기와 같은 내부피폭선량 측정 장비의 정밀한 계측이 요구되고 있다. 이러한 국내 원자력법의 개정에 부합하여 본 연구에서는 내부피폭 선량측정 결과치의 정확도를 향상시키기 위해서 현재 개발 중인 갑상선 내부피폭선량 측정 시스템의 검출효율을 계산하기 위한 몬테카를로 모의실험 코드(CALEFF)를 개발하였으며, 이 코드를 사용하여 다양한 실험조건에서 검출효율을 계산하였다. 향후 갑상선 내부피폭선량 측정 시스템의 보정인자로 사용하고자 한다.

  • PDF

Determination of counting efficiency considering the biodistribution of 131I activity in the whole-body counting measurement

  • MinSeok Park ;Jaeryong Yoo;Minho Kim ;Won Il Jang ;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.295-303
    • /
    • 2023
  • Whole-body counters are widely used to assess internal contamination after a nuclear accident. However, it is difficult to determine radioiodine activity due to limitations in conventional calibration phantoms. Inhaled or ingested radioiodine is heterogeneously distributed in the human body, necessitating time-dependent biodistribution for the assessment of the internal contamination caused by the radioiodine intake. This study aims at calculating counting efficiencies considering the biodistribution of 131I in whole-body counting measurement. Monte Carlo simulations with computational human phantoms were performed to calculate the whole-body counting efficiency for a realistic radioiodine distribution after its intake. The biodistributions of 131I for different age groups were computed based on biokinetic models and applied to age- and gender-specific computational phantoms to estimate counting efficiency. After calculating the whole-body counting efficiencies, the efficiency correction factors were derived as the ratio of the counting efficiencies obtained by considering a heterogeneous biodistribution of 131I over time to those obtained using the BOMAB phantom assuming a homogeneous distribution. Based on the correction factors, the internal contamination caused by 131I can be assessed using whole-body counters. These correction factors can minimize the influence of the biodistribution of 131I in whole-body counting measurement and improve the accuracy of internal dose assessment.

두경부암 환자의 MVCT를 이용한 치아 인공물 보정에 따른 선량평가 (Dose Evaluation of Dental Artifacts Using MVCT in Head and Neck)

  • 신충훈;윤인하;전수동;김정미;김호진;백금문
    • 대한방사선치료학회지
    • /
    • 제31권2호
    • /
    • pp.25-31
    • /
    • 2019
  • 목 적: 본 연구는 두경부암 환자의 kVCT와 MVCT영상에서 치아 인공물의 체적을 비교하고, MVCT영상에서 치아체적을 얻은 후 kVCT영상에 배정하여 치아체적 및 주변 정상조직의 전자밀도 교정 후 치료계획체적(PTV) 선량변화를 평가하고자 하였다. 대상 및 방법: 본원의 Radixact® X9에서 세기조절방사선치료를 받은 5명의 두경부암 환자를 대상으로 하였다. 환자의 MVCT영상에서 치아 및 주변 정상조직의 체적을 그린 후 kVCT영상에 영상정합 후 역방향 전산화 치료계획을 실시하였다. 처방선량지수와 선량균질지수를 이용하여 PTV 선량을 평가하였다. 결 과: kVCT영상과 MVCT영상에서 얻은 금속 인공물의 체적을 비교한 결과 평균 3.49±2.61cc, 최대 7.43cc의 차이를 보였다. PTV는 내부 치아가 충분히 포함된 곳으로 제한하였으며, PTV 선량평가 결과 인공물을 보정하지 않은 kVCT의 전산화치료계획의 CI값의 평균은 0.86, MVCT영상을 통해 인공물을 보정 한 kVCT의 CI값은 평균 0.9로 평가되었다. 결 론: 금속 인공물의 보정 없이 전산화치료계획이 이루어졌을 때 PTV의 선량이 저평가 되어 선량 불확실성이 발생됨을 알 수 있었다.

Three-dimensional conformal radiotherapy for portal vein tumor thrombosis alone in advanced hepatocellular carcinoma

  • Lee, Ju Hye;Kim, Dong Hyun;Ki, Yong Kan;Nam, Ji Ho;Heo, Jeong;Woo, Hyun Young;Kim, Dong Won;Kim, Won Taek
    • Radiation Oncology Journal
    • /
    • 제32권3호
    • /
    • pp.170-178
    • /
    • 2014
  • Purpose: We sought to evaluate the clinical outcomes of 3-dimensional conformal radiation therapy (3D-CRT) for portal vein tumor thrombosis (PVTT) alone in patients with advanced hepatocellular carcinoma. Materials and Methods: We retrospectively analyzed data on 46 patients who received 3D-CRT for PVTT alone between June 2002 and December 2011. Response was evaluated following the Response Evaluation Criteria in Solid Tumors. Prognostic factors and 1-year survival rates were compared between responders and non-responders. Results: Thirty-seven patients (80.4%) had category B Child-Pugh scores. The Eastern Cooperative Oncology Group performance status score was 2 in 20 patients. Thirty patients (65.2%) had main or bilateral PVTT. The median irradiation dose was 50 Gy (range, 35 to 60 Gy) and the daily median dose was 2 Gy (range, 2.0 to 2.5 Gy). PVTT response was classified as complete response in 3 patients (6.5%), partial response in 12 (26.1%), stable disease in 19 (41.3%), and progressive disease in 12 (26.1%). There were 2 cases of grade 3 toxicities during or 3 months after radiotherapy. Twelve patients in the responder group (15 patients) received at least 50 Gy irradiation, but about 84% of patients in the non-responder group received less than 50 Gy. The 1-year survival rate was 66.8% in responders and 27.4% in non-responders constituting a statistically significant difference (p = 0.008). Conclusion: Conformal radiotherapy for PVTT alone could be chosen as a palliative treatment modality in patients with unfavorable conditions (liver, patient, or tumor factors). However, more than 50 Gy of radiation may be required.

뇨시료 전베타 분석법을 이용한 동위원소 생산시설 종사자 내부오염 스크리닝 및 감시절차 개발 (Gross Beta Screening and Monitoring Procedure using Urine Bioassay for Radiation Workers of Radioisotope Production Facilities)

  • 윤석원;김미령;박세영;박민정;유재룡;장한기;하위호
    • Journal of Radiation Protection and Research
    • /
    • 제38권2호
    • /
    • pp.52-59
    • /
    • 2013
  • 전베타 방사능 분석법을 이용한 내부오염 스크리닝법을 검증하였고 실제 의료용 동위원소 생산시설 종사자 내부오염을 판단하는데 적용하였다. 종사자의 작업 종료 후 첫 번째로 채취된 뇨시료(spot 시료)와 24시간 동안 취합된 뇨시료(24 h 시료)를 채취하여 측정하였다. 특정 종사자의 경우를 제외하고 대부분의 측정결과는 일반인 체내 기저준위인 100 Bq $kg^{-1}$을 기준으로 22% 이내로 변동폭이 작았다. 측정결과 작업종료 후 수 시간 이내 종사자 뇨시료의 전베타 농도가 전반적으로 35% 이상 상승하는 경향이 있었다. 또한 스크리닝 결과와 작업일지를 바탕으로 작업장내부 구조상 오염을 유발하는 요인을 추정 할 수 있었으며 추가 세부 핵종별 분석법을 바탕으로 내부피폭선량을 평가해야 할 것으로 판단되었다. 한편 사업장에서 신속히 적용 가능한 내부오염평가 절차를 수립하였다.

호흡에 의해 내부 움직임을 갖는 장기에 전달되는 선량에서 Time Gating Threshold(TGT)의 효과 (An effect of time gating threshold (TGT) on a delivered dose in internal organ with movement due to respiration)

  • 김연래;정진범;서태석
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.132-135
    • /
    • 2004
  • 본 연구는 호흡시에 내부 장기가 움직일 때 시간에 따른 threshold 값을 주어졌을 때 선량분포에 대한 연구를 수행한 것이다. 이전 연구에서 보고 된 것처럼 일정 시간에 따라 움직이는 내부 장기의 움직임은 Rujan 등에 의해 보고된 3차원적 수학적 계산방법에 의해 장기의 위치를 나타내었다. 그 결과 처음exhale에서 1초동안 간의 움직임은 2mm이내에 위치하는 것을 알게 되었다. 그래서 이 연구에서 TGT는 간의 움직임이 가장 적은 처음 exhale에서 1초동안 움직일 때의 선량분포를 평가하였다. TGT 값을 주었을 때 선량분포를 비교하기 위해 다음 조건으로 방사선을 조사하였다. 1) threshold 범위에서 target이 움직일 때(1초, 1.5호), 2) threshold 없이 target이 움직일 때, 3) target이 움직이지 않을때. 각각 조건의 선량분포를 비교 평가하였다

  • PDF

PWR 사용후핵연료 중간저장시설의 몬테칼로 차폐해석 방법에 대한 계산효율성 개선방안 연구 (Development for Improvement Methodology of Radiation Shielding Evaluation Efficiency about PWR SNF Interim Storage Facility)

  • 김태만;서명환;조천형;차길용;김순영
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.92-100
    • /
    • 2015
  • 경수로 사용후핵연료 건식 중간저장시설의 방사선영향평가 효율성 개선을 목적으로 '선원항 지정방법에 따른 민감도 평가', '2-Step 계산'기법 개발 및 '냉각기간 이득효과' 적용에 따른 방사선 영향평가를 수행하였다. 본 연구에서는 저장건물의 용기배열 순서에 따라 순차적으로 선원항을 지정하여 직접선량에 미치는 민감도를 평가하였으며, 차폐건물 외벽에서의 방사선량은 내벽과 인접한 최근접 2개 열에 의한 영향이 지배적임을 확인하였다. 또한, 저장시설에 차폐 건물이 도입될 경우, 막대한 전산해석 시간을 감소시키기 위해 '2-Step 계산'기법을 수립하여 평가한 결과는 절반가량의 해석시간으로 직접(1-Step) 계산결과와 유사한 결과를 도출하였다. 마지막으로, 저장시설에 순차적으로 저장되는 저장용기의 보관기간을 사용후핵연료의 실제 냉각기간을 적용하면 건물 외벽에서의 방사선량이 냉각기간을 모두 동일하게 설정한 계산값에 비해 40% 정도 낮게 평가됨을 확인하였다. 본 연구는 중간저장시설의 방사선 영향평가를 위한 몬테칼로 차폐해석 방법의 효율성을 향상시키고자 수행되었으며, 좀 더 다양한 사례에 대한 평가를 통하여 신뢰성을 향상시킨다면 저장시설의 설계 및 부지경계 기준설정에 활용할 수 있을 것이다.