• Title/Summary/Keyword: Internal loss

Search Result 1,349, Processing Time 0.033 seconds

A Bibliographic Study on the Types of Differential Diagnosis of Amnesia (건망(健忘)의 변증분형(辨證分型)에 대(對)한 연구(硏究))

  • Choi, Yong-Jun;Seong, Gang-Gyoung;Mun, Byoung-Sun
    • The Journal of Korean Medicine
    • /
    • v.17 no.1 s.31
    • /
    • pp.374-406
    • /
    • 1996
  • This study has been carried out to investigate the types of differential diagnosis of amnesia. The results are as follows; 1. Amnesia has various types of differential diagnosis(辨證分型) ; deficiency of both the heart and spleen(心脾兩虛型), deficiency of the heart(心虛型), deficiency of the kidney(腎虛型), breakdown of the coordination between the heart and the kidney(心腎不交型), mental confusion due to phlegm(痰迷心竅型), accumulation of stagnant blood(蓄血型), internal injury by seven emotion (七情所傷型). 2. The type of deficiency of both the heart and spleen(心脾兩虛型) occurs when the heart and spleen is injured by overthinking(思慮過度), The symptoms are heart palpitation(心悸), continuous palpitation(??), insomnia(少寐), hypochondric discomfort(心煩), dream disturbed sleep(多夢), being easy to be scared(易驚), dizziness(眩暈), these are caused by blood deficiency of the heart(心血不足), poor appetite(飮食不振), loss of appetite(納?), short breath(氣短), sense of turgid abdormen(腹部膨滿感), loose stool(泥狀便), these are caused by deficiency of the spleen(脾虛), lassitude and weakness (身倦乏力), lassitude of the extremities (四肢無力), dim complexion (面色少華), pale lips(舌質淡), thready and feeble(脈細弱無力), these are caused by deficiency of both qi and the blood(氣血虛損). The remedy is nourishing the heart-blood(養心血) and regulating the spleen(理脾土). I can prescribe the recipes such as Guibitang(歸脾湯), Gagambosimtang(加減補心湯), Seongbitang(醒脾湯), Insin-guisadan(引神歸舍丹), Insamyangyoungtang(人蔘養榮湯), Sojungjihwan(小定志丸), Yungjigo(寧志膏), Palmijungjihwan(八味定志丸), etc., 3. The type of deficiency of the heart(心虛型) occurs when the heart-blood is injured by the mental tiredness(神勞) and so blood cannot nourish the heart. The symptoms are amnesia(健忘), short breath(氣短), heart palpitation(心悸), perspire spontaneously(自汗), facial pallidness(顔面蒼白), pale lips (舌質淡白), feeble pulse and lassitude(脈虛無力), intermittent pulse(結代脈). The remedy is nourishing the hart and blood and allaying restlessness(補心益血安神). I can prescribe the recipes such as Chenwangbosimdan(天王補心丹), Jeongji-hwan(定志丸), Gaesimhwan(開心丸), Youngjigo(寧志膏), Chilseonghwan(七聖丸), Baegseogyoungtang(白石英湯), Oseohwan(烏犀丸), Yangsinhwan(養神丸), Guisindan(歸神丹), Bogsinsan(茯神散), Jinsamyohyangsan(辰砂妙香散), Cheongeumboksinsan(千金茯神散), Samjotang(蔘棗湯), jangwonhwan(壯元丸), Sa gunjatang(四君子湯) minus rhizoma atractylodis macrocephalae(白朮) plus rhizoma acori graminei(石菖蒲), radix polygalae(遠志), cinnabaris(朱砂), etc. 4. The type of deficiency of the kidney(腎虛型) occurs when the kidney-qi and kidney-essence is deficient(腎氣腎精不足) and so it cannot nourish the brain. The symptoms arc amnesia(健忘), ache at the waist and lassitude in the lower extremities(腰산腿軟), dizziness and tinnitus(頭暈耳嗚), emmission and premature ejaculation(遺精早泄), burning sensation of the five centres(五心煩熱), flushed tongue(舌紅), rapid and small palse(脈細數). The remedy is nourishing the kidney and strengthen the essence(補腎益精). I can prescribe the recipes such as Gagamgobonhwan(加減固本丸), Jeongjihwan(定志丸), Gongseongchlmjungdan(孔聖枕中丹), Yugmigihwanghwan(六味地黃丸) plus ra-dix polygalae(遠志), fructus schizandrae(五味子), Yugmigihwanghwan(六味地黃丸) plus radix polygalae(遠志), fructus schizandrae(五味子), rhizoma acori graminei(石菖蒲), semen zizyphi spinosae(酸棗仁), Palmihwan(八味丸) plus fructus schizandrae(五味子), semen zizyphi spinosae(酸棗仁). etc., 5. The type of breakdown of the coordination between the heart and the kidney (心腎不交型) occurs when the heart-fire(心火) and kidney-fluid(腎水) are imbalanced. The symptoms are amnesia(健忘), hypochondric discomfort(心煩), insomnia(失眠), dizziness and tinnitus(頭最耳嗚), feverish sensation m the palms and soles(手足心熱), emmision(遺精), ache at the waist and lassitude in the lower extremities(腰?腿軟), flushed tongue(舌紅), rapid pulse(脈數). The remedy is coordinating each other(交通心腎). I can prescribe the recipes such as Gangsimdan(降心丹), Jujaghwan(朱雀丸), Singyotang(神交湯), Simsinyang- gyotang(心腎兩交湯), Yugmihwan(六味丸) plus fructus schizandrae(五味子), radix polygalae(遠志), Yugmihwan(六味丸) plus fructus schizandrae(五味子), radix polygalae(遠志), rhizoma acari graminei(石菖蒲), semen zizyphi spinosae(酸棗仁), etc., 6. The type of mental confusion due to phlegm(痰迷心竅型) occurs when the depressed vital energy(氣鬱) create phlegm retention(痰飮) and phlegm stagnancy(痰濁) put the heart and sprit(心神) out of order. The symptoms arc amnesia(健忘), dizziness(頭暈), chest distress(胸悶), nausea(惡心), dull(神思欠敏), dull and slow facial expression(表情遲鈍), tongue with yellow and greasy fur(舌苔黃?), sliperry pulse(脈滑). The remedy is removing heat from the heart to restore consciousness and dispersing phlegm(淸心化痰開竅) I can prescribe the recipes such as Gamibogryeongtang(加味茯?湯), Goa-rujisiltang(瓜蔞枳實湯), Jusaansinhwan(朱砂安神丸), Dodamtang(導痰湯) plus radix saussurea(木香), Yijintang(二陳湯) plus succus phyllostachyos(竹瀝), rhizoma zingiberis(生薑) Ondamtang(溫膽湯) plus rhizoma acori graminei(石菖蒲), rhizoma curcumae aromaticae(鬱金), etc., 7. The type of accumulation of stagnant blood(蓄血型) occurs when the blood is accumulated in the lower part of body. The symptoms are amnesia(健忘), chest distress(胸悶), icteric skin(身黃), rinsing the mouth but don't wanting eat(漱水不欲燕), madness(發狂), black stool(屎黑), pain in the lower abdomen(小腹硬痛). The remedy is dispersing phlegm and absorb clots (化痰化瘀), I can prescribe the recipes such as Jeodangtang(抵當湯), Daejeodanghwan(代抵當丸), Hyeolbuchugeotang (血府逐瘀湯) plus rhizoma acori graminei (石菖蒲), rhizoma curcumae aromaticae(鬱金), Jusaansinhwan(朱砂安神丸) plus rhizoma curcumae aromaticae(鬱金), radix polygalae(遠志), semen persicae(桃仁), cortex moutan radicis(收丹皮), etc., 8. The type of internal injury by seven emotion(七情所傷型) occurs when the anger injures the will stored in the kidney(腎志). The symptoms are amnesia(健忘), heart palpitation(心悸). hot temper(易怒), being easy to be scared(善驚), panic(易恐). The remedy is relieving the depressed liver and regulating the circulation of qi(疏肝解鬱). I can prescribe the recipes such as Tongultang(通鬱湯), Sihosogantang(柴胡疏肝湯) plus rhizoma acari graminei(石菖蒲), rhizoma curcumae aromaticae(鬱金), etc.

  • PDF

Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF

The Measurement of Blood Loss and Its Effect on Red Cell Survival Studies with $^{51}Cr$ (실혈(失血)이 적혈구수명(赤血球壽命) 측정(測定)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Lee, Mun-Ho;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.27-36
    • /
    • 1970
  • 적혈구(赤血球) 수명의 측정에는 $^{51}Cr$-표지적혈구법(標識赤血球法)이 임상적(臨床的)으로 이용(利用)되고 있으며 이는 이론상(理論上) steady state 즉(卽) 측정기간(測定期間)동안 순환(循環) $^{51}Cr$량(量)-적혈구량(赤血球量)이 일정(一定)할 때에 한(限)하여 유효(有效)하며 unsteady state 때는 true red cell survival을 알기 위하여서는 측정치에 영향을 주는 요인(要因)에 대하여 각각(各各) 교정(校正)해 줄 필요(必要)가 있다. 이 요인(要因)중에 특히 실혈(失血)로 인(因)한 영향에 관(關)하여는 계통적인 연구(硏究)가 적다. 이에 저자(著者)들은 $^{51}Cr$표지적혈구법(標識赤血球法)을 이용(利用)하여 실혈(失血)이 적혈구(赤血球) 수명측정(測定)에 미치는 영향을 인체(人體)에서 실험 관찰하여 몇가지 성적을 얻었다. 연구대상(硏究對象)은 총(總) 56명(名)의 청장년(靑壯年)으로 급성실혈군(急性失血群)과 만성실혈군(慢性失血群)으로 구분(區分)하여 급성실혈군(急性失血群)은 위장출혈등(胃腸出血等)이 없는 2대(代)의 의대생(醫大生)으로 $^{51}Cr$표지적혈구법(標識赤血球法)을 사용하여 적혈구(赤血球) 수명을 측정하는 동안($10{\sim}14$ 일간(日間)) 1일당(日當) 10ml(6명(名)), 25ml(4명(名)), 50ml(4명(名)), 75ml(4명(名)), 100ml(6명(名))를 각각(各各) 사혈(瀉血)한 군(群)과 10일간(日間) 1,000ml를 사혈한 군(群) 즉 200ml씩 5회(回)(4명(名)), 500ml씩 2회(回)(4명(名))로 세분(細分)하였으며 만성실혈군(慢性失血群)은 직업적인 공혈자(供血者)로 반복사혈로 생긴 9명(名)의 빈혈자와 십이지장충증(十二指腸蟲症)에 감염(感染)되어 구충(驅蟲)한 중등도(中等度)의 철결핍성 빈혈환자 7명(名)으로 나누어 관찰하였다. 측정(測定) 방법(方法)으로는 Gray 및 Sterling법(法)을 개설한 방법(方法)으로 $^{51}Cr$표지적혈구(標識赤血球)의 계측시료(計測試料)로서 전혈(全血) 및 적혈구(赤血球)를 사용(使用)하였다. 실험(實驗)성적은 1. 1일당(日當) 실혈량(失血量)이 증가(增加)할수록 적혈구(赤血球)수명($T\frac{1}{2}$)은 짧아짐을 알 수 있었다. 즉(卽) 1일당(日當) $20{\sim}50ml$ 사혈군에서는 $T\frac{1}{2}$이 현저히 짧아지는 rapid phase을 나타내고 1일당(日當) 50ml이상(以上) 사혈군에서는 짧아지는 정도(程度)가 완만한 slow phase을 나타낸다(Fig. 6). 2. 1일량(日量) 10ml 및 25ml식(式) 사혈한 군(群)의 적혈구수명(赤血球壽命)을 측정(測定)하는데 있어 적혈구(赤血球)를 사용하였을 때에는 $T\frac{1}{2}$측 정치에 유의한 차(差)가 없었으며 이 범위 내에서는 Hct., Hb. 및 혈청철치(血淸鐵値)도 역시 유의한 차(差)가 없었다. 3. 1일량(日量) 50ml 및 75ml, 100ml씩 사혈한 군(群)에서는 적혈구(赤血球)만을 사용(使用)하였을 때와 전혈(全血)을 시료(試料)로 하였을 때 사이에 $T\frac{1}{2}$의 측정치에 유의한 차(差)가 있었으며 이 때는 Hct., Hb. 및 혈청철치(血淸鐵値)에도 변화(變化)가 있었다. 즉(卽), 전혈(全血)을 사용한 적혈구(赤血球) 수명($T\frac{1}{2}$)의 측정치가 적혈구(赤血球)만를 사용(使用)한 적혈구(赤血球) 수명($T\frac{1}{2}$)의 측정치 보다 짧았다. 4. 일정(一定)기간(10 일(日)) 사혈의 총량(1000ml)이 같을 매는 200ml를 5회(回) 사혈한 군(群)이나 500ml를 2회(回) 사혈한 군(群) 사이에 적혈구(赤血球) 수명($T\frac{1}{2}$)에 유의(有義)한 차(差)를 볼 수 없었다. 5. 직업적 공혈자의 반복사혈로 인(因)한 만성(慢性) 빈혈환자 9명(名)에서의 $^{51}Cr$적혈구(赤血球)수명($T\frac{1}{2}$) 측정치는 평균(平均) 19.2일(日)로 짧아져 있으나 적혈구수명측정전후(赤血球壽命測定前後)에 충분(充分)한 철제(鐵劑)를 투여(投與)하여 Hct., Hb. 및 혈청철치(血淸鐵値)를 증가(增加)시켰으며 이때 볼 수 있었든 Hct치(値)를 규준(規準)하여 교정한 적혈구(赤血球)수명($T\frac{1}{2}$)은 거의 정상(正常)범위 안에 있어(27.6일(日)) 이러한 인자(因子)를 고려하지 않으면 잘못 이해할 수가 있다. 6. 구충자충(鉤蟲仔蟲)을 구충한 7명(名)의 중등도(中等度) 철(鐵)결핍성 빈혈환자에서의 적혈구(赤血球)수명($T\frac{1}{2}$) 측정치는 25일(日)$\sim$31일(日)로 평균(平均) 28일(日)이었으며, 이때 장 출혈량은 1일(日) $1.0{\sim}3.5ml$이었다. 단시일내의 급성실혈시에는 이와같은 소량의 실혈(失血)도 적혈구(赤血球)수명($T\frac{1}{2}$) 측정치에 영향을 보여 줌을 알 수 있었다. 따라서 이러한 정도의 실혈은 실험오차에 기인하는 것인지 아니면 장기 출혈에서는 이러한 소량의 실혈이 적혈구(赤血球)수명($T\frac{1}{2}$) 측정에 영향을 미치지 않는 것인지는 아직 확실히 말할 수 없다. 8. $^{51}Cr$-표지적혈구(標識赤血球)로 측정한 적혈구(赤血球)수명($T\frac{1}{2}$)은 측정시의 실혈량(失血量)에 큰 영향을 받음을 알 수 있으며 저자(著者)들은 $^{51}Cr$표지적혈구(標識赤血球)를 이용(利用)한 적혈구(赤血球) 수명 측정때 검사기간중 실혈량이 적혈구수명치(赤血球壽命値)에 미치는 관계를 상술(上述)한 실험치(實驗値)를 기초(基礎)로 하여 다음과 같을 교정식(校正式)을 고찰(考察)해 보았다. $^{51}Cr\;T\frac{1}{2}=17.0e^{-0.0495}+18.4e^{-0.000924x}$ 단(但) X : 1일(日) 실혈량(失血量)(단위(單位) ml)

  • PDF

Preoperative Evaluation for the Prediction of Postoperative Mortality and Morbidity in Lung Cancer Candidates with Impaired Lung Function (폐기능이 저하된 폐암환자에서 폐절제술후 합병증의 예측 인자 평가에 관한 전향적 연구)

  • Perk, Jeong-Woong;Jeong, Sung-Whan;Nam, Gui-Hyun;Suh, Gee-Young;Kim, Ho-Cheol;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.14-23
    • /
    • 2000
  • Background: The evaluation of candidates for successful lung resection is important. Our study was conducted to determine the preoperative predictors of postoperative mortality and morbidity in lung cancer patients with impaired lung function. Method; Between October 1, 1995 and August 31, 1997, 36 lung resection candidates for lung cancer with $FEV_1$ of less than 2L or 60% of predicted value were included prospectively. Age, sex, weight loss, hematocrit, serum albumin, EKG and concomitant illness were considered as systemic potential predictors for successful lung resection. Smoking history, presence of pneumonia, dyspnea scale(l to 4), arterial blood gas analysis with room air breathing, routine pulmonary function test were also included for the analysis. In addition, predicted postoperative(ppo) pulmonary factors such as ppo-$FEV_1$ ppo-diffusing capacity(DLco), predicted postoperative product(PPP) of ppo-$FEV_1%{\times}$ppo-DLco% and ppo-maximal $O_2$ uptake($VO_2$max) were also measured. Results: There were 31 men and 5 women with the median age of 65 years(range, 44 to 82) and a mean $FEV_1$ of $1.78{\pm}0.06L$. Pneumonectomy was performed in 14 patients, bilobectomy in 8, lobectomy in 14. Pulmonary complications developed in 10 patients; cardiac complications in 3, other complications(empyema, air leak, bleeding) in 4. Twelve patients were managed in the intensive care unit for more than 48 hours. Two patients died within 30 days after operation. The ppo-$VO_2$max was less than 10 ml/kg/min in these two patients. MVV was the only predictor for the pulmonary complications. However, there was no predictor for the post operative death in this study. Conclusions: Based on the results, MVV was the useful predictor for postoperative pulmonary complications in lung cancer resection candidates with impaired lung function In addition, ppo-$VO_2$max value less than 10 ml/kg/min was associated with postoperative death, so exercise pulmonary function test could be useful as preoperative test. But further studies are needed to validate this result.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Physicochemical Properties of Ground Pork with Lotus Leaf Extract during Refrigerated Storage (연잎추출물 첨가가 분쇄돈육의 냉장저장 중 이화학적 품질에 미치는 영향)

  • Lee, Kyung-Soo;Kim, Ju-Nam;Jung, In-Chul
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.23 no.4
    • /
    • pp.477-486
    • /
    • 2013
  • This study was carried out to investigate the effect of lotus leaf extract on the physicochemical characteristics of ground pork stored at $4^{\circ}C$ for 10 days. Four types of ground pork were evaluated: ice water added (T0), 3% lotus leaf extract added (T1), 7% lotus leaf extract added (T2), and 10% lotus leaf extract added (T3). The pH was increased during storage, but decreased after 10 days of storage (p<0.05). The TBARS increased with a longer storage period (p<0.05), and those of T0, T1, T2 and T3 were 0.777, 0.244, 0.185, 0.182 mg MA/kg, respectively, after 10 days of storage. The VBN content of T0 and T1 increased with a longer storage period (p<0.05), but those of T2 and T3 were not significantly changed. In the case of surface color, the $L^*$ increased with a longer storage period, and that of T0 was the highest (p<0.05). The $a^*$ decreased with a longer storage period, and the $b^*$ was the highest after 1 day of storage (p<0.05). In the case of internal color, $L^*$ was not significantly changed, and $a^*$ was decreased with a longer storage period (p<0.05). The $b^*$ increased with a longer storage period (p<0.05). Water holding capacity increased with a longer storage period, and those of T2 and T3 were the highest (p<0.05). Cooking loss decreased with a longer storage period, and those of T0 and T1 were higher than those of T2 and T3 (p<0.05). Hardness and chewiness were not significantly different with a longer storage period, or among any samples.

1-Methylcyclopropene and Carbon Dioxide Absorber Reduce Chilling Injury of Eggplant ($Solanum$ $melongena$ L.) during MAP Storage (1-Methylcyclopropene과 이산화탄소 제거제 처리에 의한 가지($Solanum$ $melongena$ L.) 과실의 MAP 저장 중 저온장해 경감)

  • Veasna, Hay;Hwang, Yong-Soo;Choi, Jong-Myung;Ahn, Young-Jik;Lim, Byung-Sun;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.50-56
    • /
    • 2012
  • This study was conducted to extend the postharvest life of eggplant ($Solanum$ $melongena$ L.) by modified atmosphere packaging using a OPP bag with 1-MCP to evaluate the alleviation effects of that treatment on external chilling injury during at low temperature. 1-MCP treatment at the level of $1.0{\mu}L{\cdot}L^{-1}$ were very effective in delaying the progress of surface bronzing of eggplant during 10 days of storage at $8^{\circ}C$, but not significant at $1^{\circ}C$. Also, the treatment of 1-MCP at the levels of $0.1{\sim}1.0{\mu}L{\cdot}L^{-1}$ are beneficial to complement low temperature storage and maintain quality indices such as higher firmness and lower weight loss than untreated control even at a critical low temperature 4 to $8^{\circ}C$. The treatment of carbon dioxide using dry ice (DI, 5 g/3 fruits) significantly promoted chilling injury of eggplant stored at $4^{\circ}C$, symptoms were appeared from 3 days after treatment and combination treatment of 1-MCP did not block the development of chilling injury symptom. Meanwhile, single treatment of $CO_2$ absorber (CA, 5 g/3 fruits) or combination treatment with 1-MCP at the level of $1.0{\mu}L{\cdot}L^{-1}$ prevented effectively the external and internal chilling injury at $4^{\circ}C$ during 6 days and 15 days of MAP storage, respectively. Results suggest that 1-MCP and carbon dioxide absorber treatments delay fruit deterioration and are beneficial to broaden storage temperature of eggplant fruits.

Evaluation of Fruit Quality during Shelf-life at High Temperature Environment in 'Wonhwang' and 'Whasan' Pears ('원황' 및 '화산' 배의 숙도별 고온유통환경에서의 품질 평가)

  • Lee, Ug-Yong;Oh, Kyoung-Young;Choi, Jin-Ho;Hwang, Yong-Soo;Choi, Jong-Myung;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.20 no.3
    • /
    • pp.233-240
    • /
    • 2011
  • We evaluated the changes of fruit quality factors and the incidence of physiological disorders during the periods of high temperature environment in 'Wonhwang' and 'Whasan' pears to determine appropriate harvest time for exportation. In 'Wonhwang' pears, the fruits harvested at 130 days after full bloom (DAFB) showed 31.3 and 17.6N of flesh firmness after 5 and 10 days after simulated marketing at $30^{\circ}C$, respectively, while those of the fruits harvested at 135 DAFB lowered to 16.7 or 6.9N, respectively. Whereas, 'Whasan' pear showed higher firmness during 14 days of high marketing condition than 'Wonhwang' pears which represented 30.4, 26.5 and 21.6N in the fruits harvested 145, 150 and 155 DAFB, respectively. Higher soluble solid contents and lower acidity values observed in the late harvested fruits in both cultivar along with increased marketing period at $30^{\circ}C$. Late harvested 'Wonhwang' pears showed higher respiration rate and ethylene production than early harvested ones, while those of 'Whasan' pears showed lower values regardless of fruit maturity which represented less than 50% of 'Wonhwang' pears. The incidence of physiological disorders such as internal browning, water soaking, flesh spot decay, core breakdown and pithiness appeared more severely in the fruits of 'Wonhwang' in accordance with the progress of high temperature marketing and fruit maturity. Whereas, those symptoms were occurred only after 14 days of prolonged marketing time in 'Whasan' pears. Consequently, it was needed to pay more attention to determine the ripeness when the fruits exported to the country with high temperature environment, especially in the fruits of 'Wonhwang' pears showing rapid quality loss and severe physiological disorders.

Effect of Selenium on Internal Quality of Basil (Ocimum basilicum L.) During Storage (Basil 양액재배 시 Selenium 첨가가 저장 중 품질에 미치는 영향)

  • 박권우;김민순;강호민;이문정
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.193-200
    • /
    • 2000
  • The object of this study is to investigate the quality change of sweet basil grown with selenium(Se) in hydroponic culture. Sweet basil was cultured with 1 fold herb nutrient solution as suggested by European vegetable R & D Center in Belgium. Before three weeks harvest, sodium selenate(N $a_2$Se $O_4$) was supplied to 2 and 4 mg. $L^{-1}$ in the nutrient solution. Sweet basil was stored at 1$0^{\circ}C$ using 40um ceramic film and PET (polyethylene terephalate) for 15 days in modified atmosphere(MA) storage condition. The weight loss of sweet basil was higher in non-treatment compared to Se treatments in both of two films but it was decreased over 5% in PET treatment. Se concentrations in leaf tissues increased in the response to the treated levels of N $a_2$Se $O_4$concentrations, and this tendency was appeared similar results after storage. There was no significant effect of packing materials on volatilization of Se in sweet basil. The total chlorophyll and essential oil content was increased with increasing N $a_2$Se $O_4$concentration in nutrient solution. The amount of volatilization flavor was not higher at N $a_2$Se $O_4$4mg. $L^{-1}$ treatment compare to others during storage. Se content was 112.73 ug. $g^{-1}$ dry mass at 2 mg. $L^{-1}$ treatment before storage and the decrease of Se content was observed by 50% at 15 days after storage. The condition, which N $a_2$Se $O_4$2mg. $L^{-1}$$^{plement}$ in nutrient solution during growth stage and stored with 40um ceramic film on 1$0^{\circ}C$are acceptable for maintaining of sweet basil quality. Moreover it can be a proper Se concentration for human health. Overall, Se treatment in nutrient solution has effect on promoting and maintaining quality of herb during storage life. Also, there was not significant change of essential oil compounds by volatilization of Se.mpounds by volatilization of Se.

  • PDF