• 제목/요약/키워드: Internal heat exchange

검색결과 29건 처리시간 0.031초

ONAN 모드 4250kVA 변압기의 구조 건전성과 냉각 성능의 평가 (Evaluation of Structural Integrity and Cooling Performance of 4250 kVA Power Transformer with ONAN Mode)

  • ;김성익;조종래
    • 한국기계가공학회지
    • /
    • 제20권7호
    • /
    • pp.48-57
    • /
    • 2021
  • The main research content of this paper is to evaluate the structural integrity and the cooling performance of 4250 kVA power transformer with ONAN(Oil Natural and Air Natural) mode. The dynamic analysis is used to verify the structural safety of the transformer by seismic loading. The transformer structure is simplified and NX software is used to build a three-dimensional model, and ANSYS commercial software is used to calculate the stress and deformation by applying corresponding load. The analysis result was evaluated whether it satisfies the design requirements according to the IEEE Std 693 standard. In terms of thermal analysis to evaluate the cooling performance, the thermal physical model is used to calculate the heat exchange between the radiator and the tank in the steady state, and the result is input into the Fluent software to calculate the internal temperature field of the transformer tank, which reduces the calculation cost of thermal fluid. Comparing the simulated hot spot temperature and top oil temperature of the transformer with the calculation results of the IEC60076 classic model, it is found that the error is only 1.9%.

차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구 (An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter)

  • 김진희;김영탁;이수열;최원기
    • 토지주택연구
    • /
    • 제12권1호
    • /
    • pp.129-137
    • /
    • 2021
  • 외부 차양장치는 대표적인 여름철 일사조절 장치이다. 특히 냉방부하가 높은 업무용 건물에 적합한 기술로 인식되어왔다. 그러나 본 연구에서는 차양장치의 냉방부하 저감뿐만 아니라 난방부하 저감 효과를 검증하기 위한 실험을 수행하였다. 이를 위해 겨울철 야간 천공복사냉각에 따른 영향을 중심으로 일반 창호, 롤 블라인드, 외부 차양장치를 대상으로 실험을 수행하였으며, 그 결과는 다음과 같다. 외부 차양장치가 적용된 경우 유리 내·외표면 온도차는 평균 11.8℃로 차양장치가 없는 경우의 14.6℃ 보다 평균 2.8℃ 낮은 온도차를 나타냈으며, 이는 천공복사에 의한 열교환으로 차양 표면온도가 외기온도보다 낮은 시간때에 발생한다. 한편, 롤 블라인드는 내부 중공층의 평균온도보다 0.8℃ 낮은 온도를 나타냈으며 이 또한 투과체를 통과한 천공복사가 롤 블라인드 표면과 열교환이 이뤄졌기 때문이다. 유리 외부 표면온도만을 고려하면 약 3℃ 이상의 온도 상승이 예상된다. 그리고 차양장치가 없는 경우 일반적인 온도구배를 나타내고 있었다. 한편 남동향과 남서향에 외부 차양장치가 설치되었을 때 남서향의 외측 유리 표면온도가 더 낮게 나타나는 특징이 있다. 이 결과는 천공복사에 의한 냉방 저감 효과를 정량화할 수는 없지만 적어도 타당성은 확인할 수 있었다. 향후 연구에서는 천공복사 냉각과 에너지 소비 사이의 상관관계를 조사하고 외부 차양장치의 난방에너지 절감 효과에 대한 독립 챔버 실험을 진행할 계획이다.

전산유체역학을 이용한 Fischer-Tropsch 마이크로채널 반응기 반응채널구조에 따른 열적 효과 분석 (Analysis on Thermal Effects of Process Channel Geometry for Microchannel Fischer-Tropsch Reactor Using Computational Fluid Dynamics)

  • 이용규;정익환;나종걸;박성호;;한종훈
    • Korean Chemical Engineering Research
    • /
    • 제53권6호
    • /
    • pp.818-823
    • /
    • 2015
  • 본 연구에서는 전산유체역학(CFD)을 이용하여 마이크로채널 내부의 Fischer-Tropsch(FT) 반응을 모사하였고, 나아가 반응채널의 너비와 높이, 냉각채널과의 거리 그리고 채널 사이 간격을 변수로 두고 채널 내부 온도에 대해 민감도 분석을 수행하였다. 마이크로채널 반응기는 채널 간의 열교환을 고려하기 위한 5개의 반응채널과 냉각채널을 대신한 냉각면으로 이루어져 있으며 채널의 높이와 너비를 포함한 변수들의 길이는 0.5 mm ~ 5.0 mm 범위에서 설정하였다. 반응물로는 $H_2$와 CO의 혼합기체($H_2/CO$ molar ratio=2)를 사용하였으며 반응기의 운전 조건은 $GHSV=10000h^{-1}$, 압력 20 bar와 온도 483 K($210^{\circ}C$)이다. 민감도 분석의 결과로 반응채널 내부의 최대 온도는 채널의 높이에 비례하며 너비에 대해서는 특정 길이 이상에서 영향을 받지 않는 것을 확인하였으며 이 중에 냉각채널과의 거리와 채널 사이 간격은 채널 내부 온도에 거의 영향을 미치지 않았다. 따라서 채널 레이아웃에서 반응채널의 높이는 짧을수록(약 2 mm 이하), 너비는 길수록(약 4 mm 이상) 열제거뿐만 아니라 생산량 측면에서 이득을 얻을 수 있었다.

효소를 이용한 말쥐치의 탈피 (Removal of Skin from Filefish Using Enzymes)

  • 김세권;변희국;최광덕;노호석;이원희;이응호
    • 한국수산과학회지
    • /
    • 제26권2호
    • /
    • pp.159-172
    • /
    • 1993
  • Collagenase existed in the internal organs of filefish Novoden modestrus was isolated with ammonium sulfate and was purified by ion exchange column chromatography with DEAE-Sephadex A-50 and gel filtration with Sephadex G-150. The activity of the purified enzyme was increased 92.4 folds than that of the crude one and the yield of the purified one was $10.9\%$. The optimum conditions showing the maximum activity of the crude enzyme to digest insoluble collagen(Type I) were $55^{\circ}C$ and pH 8.0, while those showing the maximum activity of the purified one were $55^{\circ}C$ and pH 7.75. However, the use of the crude enzyme for skinning of filefish was more profitable because the yield was 800 folds higher than that of the purified one and the cost was also able to economy. When hydrolysis for skinning of filefish was conducted with $0.3\%$(w/w) crude collagenase at $50^{\circ}C$ and pH 8.0 for 3hrs, there was some problem to cause a damage on muscle of the fish by heat. To solve such problem for the skinning, the hydrolysis at $18^{\circ}C$ for 4hrs with $0.3\%$ (w/w) crude enzyme after pretreated with 0.5M acetic acid for 10 min provided a good result for skinning of filefish.

  • PDF

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • 분석과학
    • /
    • 제37권2호
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.

라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구 (A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter)

  • 민세홍;배연준
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.168-177
    • /
    • 2011
  • 본 연구에서는 현재 상업용으로 가장 많이 사용되고 있는 멀티시스템형 에어컨실외기의 화재 위험성을 평가하기 위하여 에어컨실외기의 실물 연소실험을 수행하였다. 그 결과 에어컨실외기는 내부 폭발과 상부 배출 그릴을 통한 급격한 화염분출 및 화재확산을 보였으며, 이는 실외기 내부에 내장된 전선, 전자 제어판, 열교환용 동판 및 합성수지류 등의 가연물이 연소하고 냉매가스가 충전된 배관이 가열로 인해 파괴되어 냉매가스가 분출되면서 화재폭발과 외부로 화염분출을 가속시켜 일어난 것이다. 본 실험에서 에어컨실외기의 최고 열방출율은 5,830 kW로 나타났으며, 열화상 카메라 및 열전대에 의해 측정된 실외기의 내부 온도는 최고 $1,201^{\circ}C$이고, 외부온도는 최고 $881^{\circ}C$ 이상, 화염의 길이는 약 5 m 이상 상승하였다. 그러므로 에어컨실외기의 화재는 주변 가연물을 발화시키는 원인으로 작용하여 건축물에 2차 화재를 발생시킴으로써 큰 피해를 줄 수 있을 것으로 판단된다. 이러한 실물실험에서 얻어낸 결과는 향후 컴퓨터시뮬레이션에서 에어컨실외기의 화재구현 및 주변 가연물로의 화재 확산 예측에 적용될 수 있을 것이다.

건물에너지시뮬레이션을 활용한 연동형 온실 및 작물에너지모델 설계 및 이의 냉·난방부하 산정 (Design of Energy Model of Greenhouse Including Plant and Estimation of Heating and Cooling Loads for a Multi-Span Plastic-Film Greenhouse by Building Energy Simulation)

  • 이승노;박세준;이인복;하태환;권경석;김락우;여욱현;이상연
    • 생물환경조절학회지
    • /
    • 제25권2호
    • /
    • pp.123-132
    • /
    • 2016
  • The importance of energy saving technology for managing greenhouse was recently highlighted. For practical use of energy in greenhouse, it is necessary to simulate energy flow precisely and estimate heating/cooling loads of greenhouse. So the main purpose of this study was to develope and to validate greenhouse energy model and to estimate annual/maximum energy loads using Building Energy Simulation (BES). Field experiments were carried out in a multi-span plastic-film greenhouse in Jeju Island ($33.2^{\circ}N$, $126.3^{\circ}E$) for 2 months. To develop energy model of the greenhouse, a set of sensors was used to measure the greenhouse microclimate such as air temperature, humidity, leaf temperature, solar radiation, carbon dioxide concentration and so on. Moreover, characteristic length of plant leaf, leaf area index and diffuse non-interceptance were utilized to calculate sensible and latent heat exchange of plant. The internal temperature of greenhouse was compared to validate the greenhouse energy model. Developed model provided a good estimation for the internal temperature throughout the experiments period (coefficients of determination > 0.85, index of agreement > 0.92). After the model validation, we used last 10 years weather data to calculate energy loads of greenhouse according to growth stage of greenhouse crop. The tendency of heating/cooling loads change was depends on external weather condition and optimal temperature for growing crops at each stage. In addition, maximum heating/cooling loads of reference greenhouse were estimated to 644,014 and $756,456kJ{\cdot}hr^{-1}$, respectively.

개방형 U-type 기화기의 부식손상부 진단기법 개발 및 적용 (The Development and its Application of Diagnostic Technique for Corrosion Defect of U-type Open Rack Vaporizer)

  • 장상엽;이성민;오병택;고영태
    • 한국가스학회지
    • /
    • 제5권3호
    • /
    • pp.45-50
    • /
    • 2001
  • 개방형 기화기는 해수를 이용하여 열교환을 수행함으로써 액체상태의 액화천연가스를 천연가스로 기화시키는 역할을 한다 86년부터 가동된 U-tyre 기화기는 천연가스생산과 관련된 중요설비 중 하나로서, 기화기 튜브는 항상 해수내에서 운전되고 있으며 기화기 튜브와 파이프사이의 용접부에서 해수로 인한 부식이 진행되고 있다. 본 연구에서는 용접부에서의 국부적인 부식원인을 찾기 위해 이종금속부식의 가능성을 평가해 보았으며 또한 비파괴적인 방법을 이용하여 부식피트의 깊이를 측정하고 유한요소를 통한 안전성 평가에 목적을 두었다. 이종금속부식가능성에 대하여 용접부 각 부위별로 시료를 채취하여 3.5$\%$(wt.) NaCl 용액내에서 모재와 용접부위의 부식전위를 측정하였으며, 비파괴 검사를 통한 잔류두께측정은 tangential radio-graphy 시험이 가장 신뢰성 있는 기법임이 확인되었다. 미세한 부식피트가 발생된 경우에는 표면형상 복제기법을 적용하였다. 비파괴적인 방법을 이용하여 산출된 부식피트의 깊이와 형상을 근거로 2차원 유한요소 해석을 수행함으로써 내압으로 인한 기화기 튜브의 안전성을 평가할 수 있었다.

  • PDF

공기유동해석을 통한 온실내 식물군 미기상 분석기술 개발 - (2)온실내 대기환경에 미치는 작물의 영향 분석을 위한 CFD 모델개발 - (Development of an Aerodynamic Simulation for Studying Microclimate of Plant Canopy in Greenhouse - (2) Development of CFD Model to Study the Effect of Tomato Plants on Internal Climate of Greenhouse -)

  • 이인복;윤남규;;;이성현;김경원;홍세운;성시흥
    • 생물환경조절학회지
    • /
    • 제15권4호
    • /
    • pp.296-305
    • /
    • 2006
  • 변화무쌍한 기상변화가 실험의 정확도에 미치는 영향을 최대한 줄일 수 있도록 강제환기식 온실에서 실험을 하였고, 또한 대체적으로 크지 않은 온실에서의 실험으로 인하여 CFD모델결과의 오차를 크게 줄일 수 있었다. CFD와 현장실험 결과를 비교하여 본 결과, 온실내 1m높이에서의 평균풍속이 각각 $0.42m{\cdot}s^{-1}$$0.39m{\cdot}s^{-1}$으로써 CFD의 지점별 오차 평균값은 7.7% 로 나타났다. Y8.5m 지점에서 가장 큰 오차가 발생하였는데, 최대 오차는 -53.8%로 나타났다. 이의 가장 큰 이유로는 온실 길이방향에서 중간지점인 Y8.5m에서 풍속이 매우 작았기 때문에 소숫점 2번째 자리의 차이라고 해도 큰 오차로 나타났다. 작물형상의 기하학적 복잡성이 매우 큰 것을 고려한다면 오차범위는 매우 양호한 것으로 판단된다. 온실내 1m높이에서 평균온도의 CFD 평균오차는 2.2%로 나타났고, 최대편차는 5.5%이었다. 온실내 바닥으로부터의 복사열 발생량의 차이로 인하여 온실내 동쪽 지역에 상대적으로 큰 오차가 발생하였다. 외기 상대습도가 44%일 때, CFD상대습도의 오차는 2.1%이었으며, 최대 오차는 -3.8%이었다. 식물군의 공기유동저항, 식물군의 수분 및 열평형 모델을 추가하여 보다 사실적인 CFD모델을 설계하였다. CFD 모델의 설계방법이 정립되었기 때문에, 추후에 온실내 다른 작물의 미기상 및 이의 온실내 기상에 미치는 영향 등을 정량적으로 분석할 수 있게 되었다. 또한 작물의 적정생육환경에 주요 대상이면서도 동시에 센서설치의 어려움 등으로 인하여 연구에 어려움이 많았던 작물군내 미기상을 연구할 수 있는 토대를 마련하였다.