• Title/Summary/Keyword: Internal fixation with plate

Search Result 108, Processing Time 0.027 seconds

Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

  • Kim, Young Min;Lee, Jong Hun
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.297-303
    • /
    • 2019
  • Background: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS), or various combinations of these polymers. The degradation patterns of absorbable plates made from different polymers and clinical courses of patients treated with such plates have not been fully identified. This study aimed to confirm the clinical courses of facial bone fracture patients using absorbable plates and compare the degradation patterns of the plates. Methods: A retrospective chart review was conducted for 47 cases in 46 patients who underwent open reduction and internal fixation surgery using absorbable plates to repair facial bone fractures. All surgeries used either PLA/PGA composite-based or poly-L-lactic acid (PLLA)/hydroxyapatite (HA) composite-based absorbable plates and screws. Clinical courses were confirmed and comparisons were conducted based on direct observation. Results: There were no naturally occurring foreign body reactions. Post-traumatic inflammatory responses occurred in eight patients (nine cases), in which six recovered naturally with conservative treatment. The absorbable plates were removed from two patients. PLA/PGA compositebased absorbable plates degraded into fragments with non-uniform, sharp surfaces whereas PLLA/HA composite-based absorbable plates degraded into a soft powder. Conclusion: PLA/PGA composite-based and PLLA/HA composite-based absorbable plates showed no naturally occurring foreign body reactions and showed different degradation patterns. The absorbable plate used for facial bone fracture surgery needs to be selected in consideration of its degradation patterns.

Metastasis of renal cell carcinoma around suture anchor implants

  • Baek, Samuel;Shin, Myung Ho;Kim, Tae Min;Oh, Kyung-Soo;Lee, Dong Ryun;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.110-113
    • /
    • 2021
  • We present an unusual case of bone metastases from renal cell carcinoma around orthopedic implants in a 78-year-old female with osteolytic, expansile, highly vascularized, malignant infiltration around suture anchors in the proximal humerus. The patient had undergone arthroscopic rotator cuff repair using suture anchor implants 6 years previously. After diagnosis of bone metastasis, she was successfully treated with metastasectomy and internal fixation using a plate and screws, with cement augmentation. This report is the first to document metastases around a suture anchor in a bone and suggests the vulnerability of suture anchor implants to tumor metastasis.

Outcome of Open Reduction Via Retromandibular Approach for Mandibular Subcondyle Fracture (하악골 과두경부 골절에 있어서 후하악부 절개법을 이용한 관혈적 정복술의 유용성)

  • Lee, Hyung Chul;Kang, Dong Hee;Koo, Sang Hwan;Park, Seung Ha
    • Archives of Plastic Surgery
    • /
    • v.32 no.6
    • /
    • pp.739-743
    • /
    • 2005
  • Subcondylar fractures have generally been treated by intermaxillary fixation except in cases where there is an absolute indication for open reduction. The reason behind a less aggressive surgical approach lies on the inherent difficulties in manipulating fragments in such a small area at the risk of damaging facial nerves or vessels such as the internal maxillary artery. However, long-term follow-up studies showed that conservative treatment of subcondylar fractures results in disturbances of occlusal function, deviation of the mandible, internal derangement of the temporomandibular joint, and ankylosis of the joint. We carried out open reduction of dislocated subcondylar fractures in 14 patients from 2000 to 2004 by a retromandibular approach. After the reduction of fractured bone, two H-shaped miniplates with 6 holes were fixed with screws at the anterior and posterior surfaces of the subcondyle. The retromandibular approach allowed good access and easy manipulation of the subcondyle. Immediate relief from malocclusion and correction of mandibular midline shifting were observed in all patients. Late temporomandibular dysfunction and ankylosis were not observed. Open reduction with plate osteosynthesis made it possible to avoid IMF in 7 of the 14 patients. The present study shows that open reduction through this retromandibular approach can produce good outcome in adult patients with subcondylar fracture.

The Removal of Plates after Craniomaxillofacial Surgery: A Retrospective Study (두개 악안면 수술 후 플레이트 제거에 관한 후향적 연구)

  • Park, Dae-Kyun;Yoo, Sang-Chul;Park, Seung-Ha;Koo, Sang-Hwan
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.186-190
    • /
    • 2007
  • Purpose: Plate systems have been used for osteosynthesis of cranial and oromaxillofacial fracture. However, there is no consensus on the need for routine removal of plate and the question about indications of removal. Therefore, we present the retrospective study to clarify the indications and consensus of removal. Methods: The medical records of patients who were treated with rigid internal fixation using plates after craniofacial trauma were reviewed. Study variables included age, gender, type of fracture, type of plate, seniority of the operator, causes of removal, and time between insertion and removal. All results amendable to statistics were analyzed using SPSS 10.0 to determine which set of variables might affect the fate of the plates. Results: For a period of 10 years (March 1, 1994 through July 31, 2004), total of 41 plates(6.7%) were removed among 609 plates inserted into 419 patients; 27 plates were removed from 15 patients for infection, which is the most common cause of removal accounting for 65.8%. Mean time between insertion and removal is 35.2 months and mean age is 41.4 years. Most plates were removed from combined fracture(14.92%) and facial fracture(8.47%) and these were statistically significant. The age, gender, seniority of the operator and other variables were not statistically associated with plate removal. Conclusion: This retrospective study shows that routine removal does not appear to be clinically indicated due to respectively low removal rate and that the commonest indications for removal were infection.

Arthroscopic Cannulated Screw Fixation Technique for Avulsion Fracture of the Intercondylar Eminence of the Tibia (삽관 나사못(Cannulated screw)을 사용한 경골 과간 융기부 견열 골절의 관절경적 치료 기법)

  • Lee, Kee-Byoung;Chang, Ho-Guen;Lee, Seok-Beom;Moon, Young-Wan;Kang, Ki-Hoon;Lee, Wook-Hyung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.127-131
    • /
    • 1999
  • Avulsion fractures of the intercondylar eminence of the tibia are not uncommon. In the displaced avulsion fracture, anatomical reduction and firm fixation of fracture fragments are needed but the most of the conventional operative techniques including arthroscopic technique are relatively complex and need. The results were not always satisfactory due to the risk of postoperative complications such as wound infection, premature epiphyseal closure and loss of fixation after early motion etc. So we describe a simple and safe modified method of arthroscopic reduction and fixation for avulsion fractures of the intercondylar eminence of the tibia. In our thirteen cases, we achieved anatomical reduction and secure fixation using cannulated screw through the three arthroscopic portals (anterolateral, medial mid-patellar and central). Postoperatively, immediate limited range of motion of the knee and partial weight bearing were possible. Additional use of the washer afforded safe fixation of comminuted avulsion fracture. The advantage of this technique includes its technical simplicity, easy removal of hardware, ability to treat comminuted type IV fracture with washer, no additional skin incision, no damage to growing plate in growth children and less morbidity.

  • PDF

Treatment of Distal Tibial Metaphyseal Fracture Using MIPPO Technique (MIPPO 수기를 이용한 원위 경골 골간단 골절의 치료)

  • Lee, Ho-Seung;Kim, Jung-Jae;Oh, Se-Kwan;Ahn, Hyung-Sun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.166-170
    • /
    • 2004
  • Purpose: To evaluate the results of MIPPO (minimal invasive percutaneous plate osteosynthesis) technique for distal tibial metaphyseal fractures. Materials and Methods: It is a retrospective study of 13 patients who were treated by MIPPO technique for distal tibial metaphyseal fractures from Jan. 2001 to Jan. 2003. The average age was 46.7 years and mean follow-up period was 13.3 months. According to AO classification, there were 8 cases of A1, 3 cases of A2, 1 case of B1 and 1 case of C2. One case of A1 was a Gustilo-Anderson type I open fracture and fibular fractures were combined in 12 cases. We applied anatomical reduction and internal fixation for the fibular fractures and internal fixation on the medial side of the tibia by MIPPO technique for distal tibial metaphyseal fractures. Clinical results were evaluated using radiographic results, Neer score, the starting time of postoperative exercise and clinical complications. Results: According to the Neer score, all cases showed satisfactory results. Active ankle ROM was started at average 2.4 weeks ($2{\sim}4$ weeks) and full weight bearing ambulation at average 5.2 weeks ($4{\sim}8$ weeks) postoperatively. Union of fractures was obtained by average 14.4 weeks ($8{\sim}18$ weeks) postoperatively. Two cases showed $5^{\circ}$ limitation of motion without functional deficits and other cases showed satisfactory ROM results. One case had $6^{\circ}$ valgus deformity without functional deficits. There were not any other complications like soft tissue problems and delayed-or non-union. Conclusion: MIPPO technique for the treatment of distal tibial metaphyseal fractures is a feasible technique with a good clinical outcomes.

  • PDF

Bone Replacement and Grafting with a Biologically Active Ceramic Composite

  • McGee, Thomas Donald
    • The Korean Journal of Ceramics
    • /
    • v.7 no.1
    • /
    • pp.41-44
    • /
    • 2001
  • A composite of $Ca_3$(PO$_4$)$_2$ and MgAl$_2$O$_4$ spinel is biologically active and has enduring strength. Its strength depends on the spinel phase. The flaws in the spinel depend on the grain size of the calcium phosphate phase and are not altered by dissolution. The calcium phosphate, ${\alpha}$ tri-calcium phosphate, controls the tissue response. Bone bonds to the implant. A design for a bone graft as a replacement for a section of the diaphysis of a canine femur provides for tensile, compressive, torsional and bending load; and for the physiological processes of bonding and remodeling. A bone plate, used to stabilize the implant at time of surgery was removed after about one year. Over seven years of service have been achieved without internal or external fixation.

  • PDF

Refracture after locking compression plate removal in displaced midshaft clavicle fractures after bony union: a retrospective study

  • Park, Ho-Youn;Kim, Seok-Jung;Sur, Yoo-Joon;Jung, Jae-Woong;Kong, Chae-Gwan
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.2
    • /
    • pp.72-79
    • /
    • 2021
  • Background: A midshaft clavicle fracture is a common fracture that typically responds well to open reduction and internal fixation (ORIF). However, refracture can occur after implant removal (IR). This study aimed to analyze the rate of refracture and related factors after removal of the locking compression plate (LCP) for displaced midshaft clavicle fractures. Methods: We retrospectively reviewed the medical records of 201 patients who had undergone ORIF with LCP for midshaft clavicle fractures after IR after bony union from January 2011 to May 2018 at our institute. We evaluated basic demographic characteristics and radiographic parameters. All patients were treated with an LCP for primary fracture. The patients were divided into two groups: a refracture group that experienced a second fracture within 1 year after IR and a no-fracture group. Results: There were four cases (1.99%) of refracture; three were treated conservatively, while one was treated surgically. All patients achieved bony union. The average interval between refracture and IR was 64 days (range, 6-210 days). There was a significant difference in classification of fractures (AO Foundation/Orthopaedic Trauma Association [AO/OTA] classification) between the two groups. However, other patient demographics and radiographic measurements between refracture and IR, such as bone diameter, showed no significant difference between the two groups. Conclusions: This study showed that one in 50 patients suffered from refracture after removal of the LCP. Thus, if patients desire IR, the surgeon should explain that there is a relatively higher possibility of refracture for cases with simple or segmental fractures than for other types of fracture.

Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures (AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과)

  • Kim, Young-Mo;Lee, June-Kyu;Yang, Jae-Hoon;Kim, Bo-Kun;Lee, Won-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Purpose: To evaluate the usefulness of minimally invasive arthroscopy-assisted plate removal of a laterally inserted periarticular distal femur plate used for the treatment of AO type-C distal femur fractures. Materials and Methods: From October 2002 to November 2005, we evaluated 17 patients whose plates were removed through minimally invasive arthroscopy-assisted plate-removal technique and 15 patients who got their plates removed through conventional method without using arthroscopy, 32 patients in total. All these patients included in this study initially underwent open reduction and internal fixation of the distal femoral fractures with a lateral plate, and complained of continued pain over the lateral femoral condyle after the fracture fixation. The average age was 42.6 (ranges: 20~66) and initial fracture types included 16 cases of C1, 11 cases of C2, and 5 cases of C3 following AO/ASIF classification guidelines. Measured outcomes included: associated intra-articular pathologies, time needed to return to activities of daily living, patients' overall satisfaction, complications following the removal of hardware, and pain before and 6 months after the operation. Results: The distal-most end of the plate was placed in the knee joint in all cases and damage of the lateral articular capsule was found in 23 cases. Continuous wound discharge after surgery was found in one case who underwent arthroscopy-assisted plate removal, and it was treated by irrigation and re-suture. Average time needed to return to activities of daily living was 7 days in arthroscopy assisted group and 7.6 days in conventionally removed group. Fourteen patients (82.4%) who underwent arthroscopyassisted plate-removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 4.9 to 1.9, six months after the plate removal. Thirteen patients(86.7%) who underwent conventional plate removal reported above 'fair' satisfaction and the Visual analog scale pain score decreased from 5.2 to 2.5, six months after the operation. Conclusion: Through minimally invasive arthroscopic-assisted plate removal, intrarticular pathology of the knee joint was able to be simultaneously identified and treated at the time of hardware removal. Damage of lateral capsule of the knee joint caused by the inserted plate for the treatment of type C distal femoral fracture was very frequently found and following the plate removal, patients experienced an improvement in pain score. We therefore recommend routine lateral distal femoral plate removal if the bony union is attained in such cases as type C distal femoral fractures whose distal most end of the plates are located in the joint.

  • PDF

The Size of Calcaneus in Koreans (한국인의 종골 크기)

  • Kim, Jin-Su;Cho, Hun-Ki;Hwang, Sae-Min;Lee, Keun-Woo;Young, Ki-Won;Lee, Kyung-Tai
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.143-149
    • /
    • 2013
  • Purpose: Open reduction and internal fixation of calcaneal fracture using plate has been used. While numerous plates have been manufactured, most of the conventional plates are designed for westerners, realistically the size is larger for Korean. The domestic products, on the other hand, often have the undesirable screw holes and path. Therefore, we measured the radiologic parameter of Korean calcaneus for providing the plate and screw hole placements. Materials and Methods: We measured the outer lines and angles with over the 20 years old 291 females and 322 males. A: Length of inferior plane of calcaneus, B: Length of anterior plane of calcaneus, C: Length from line A to sinus tarsi, D: Length from line A to posterior point of posterior facet, E: Length from line A to calcaneal tuberosity, F: Length of posterior facet, G: Length from anterior point of line A to C, H: Length from line C to line D, a: Angle between A and B, b: Gissane angle, c: Bohler angle, d: Calcaneal pitch angle using Marosis m-view$^{(R)}$. Results: Mean A, B, C, D, E, F, G, H were 63.6, 26.4, 23.2, 43.7, 40.5, 26.9, 12.8, 18.1 mm. Mean a, b, c, d angle were 105.8, 122.4, 32.4, $20.5^{\circ}$. Male's calcaneus is significantly bigger than female's (p<0.001). Conclusion: AP calcaneus length 63.6 mm, maximal height 43.7 mm is considered to be helpful in making the Korean calcaneal plate.