• Title/Summary/Keyword: Internal fixation with plate

Search Result 109, Processing Time 0.026 seconds

The Size of Calcaneus in Koreans (한국인의 종골 크기)

  • Kim, Jin-Su;Cho, Hun-Ki;Hwang, Sae-Min;Lee, Keun-Woo;Young, Ki-Won;Lee, Kyung-Tai
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.143-149
    • /
    • 2013
  • Purpose: Open reduction and internal fixation of calcaneal fracture using plate has been used. While numerous plates have been manufactured, most of the conventional plates are designed for westerners, realistically the size is larger for Korean. The domestic products, on the other hand, often have the undesirable screw holes and path. Therefore, we measured the radiologic parameter of Korean calcaneus for providing the plate and screw hole placements. Materials and Methods: We measured the outer lines and angles with over the 20 years old 291 females and 322 males. A: Length of inferior plane of calcaneus, B: Length of anterior plane of calcaneus, C: Length from line A to sinus tarsi, D: Length from line A to posterior point of posterior facet, E: Length from line A to calcaneal tuberosity, F: Length of posterior facet, G: Length from anterior point of line A to C, H: Length from line C to line D, a: Angle between A and B, b: Gissane angle, c: Bohler angle, d: Calcaneal pitch angle using Marosis m-view$^{(R)}$. Results: Mean A, B, C, D, E, F, G, H were 63.6, 26.4, 23.2, 43.7, 40.5, 26.9, 12.8, 18.1 mm. Mean a, b, c, d angle were 105.8, 122.4, 32.4, $20.5^{\circ}$. Male's calcaneus is significantly bigger than female's (p<0.001). Conclusion: AP calcaneus length 63.6 mm, maximal height 43.7 mm is considered to be helpful in making the Korean calcaneal plate.

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Hypoplagia of Right Clavicle Associated with Neurofibromatosis (A Case Report) (쇄골의 저형성을 동반한 신경섬유종증(증례보고))

  • Choi Chang-Hyuk;Kwun Koing-Woo;Kim Shin-Kun;Lee Sang-Wook;Yun Gi-Hyun;Kim Yong-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.132-137
    • /
    • 1998
  • Neurofibromatosis is characterized by its skeletal involvement and cutaneous manifestation. Some patients develop focal area of hypoplasia and atrophy at limbs. We present the case of a 13-year-old boy with a fracture of the hypoplastic clavicle associated with neurofibromatosis and brownish cutaneous macules. The patient received open reduction and internal fixation with a semitubular plate and biopsy was done in order to clarify the pathology.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

COMPLICATIONS ASSOCIATED WITH OPEN REDUCTION OF MANDIBULAR FRACTURES (관혈적 정복술로 치료한 하악골 골절에서의 합병증)

  • Park, Young-Ah;Sohn, Woo-Ill;Chang, Ic-Jun;Song, Jae-Chul;Chin, Byung-Rho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.474-480
    • /
    • 2001
  • Purpose: The aim of this study was to evaluate the complications of open reduction and internal fixation of mandibular fracture with miniplates. Patients and Methods: A total of 134 patients who presented with 196 fractures were analyzed retrospectively. Complications were evaluated for factors such as age, the site of fracture, the severity of fracture, delayed operation, preoperative wound contamination, the site and disposition of teeth in the fracture line and midfacial fractures. Statistical analysis was used to compare complications to risk factors. Results: Of the 134 patients, 20 patients had some form of postoperative complications and complication rate was 14.9%. These complications included infection, plate fracture, malocclusion, wound dehiscence, nerve injury and nonunion. There was a significant correlation between complication rate and the severity of fracture, preoperative wound contamination and the site of the fracture and disposition of teeth(p<0.05). Conclusion: The occurrence of postoperative complications in the treatment of mandibular fractures was related to the severity of fracture, preoperative wound contamination and the site of the fracture and disposition of teeth.

  • PDF

Recycling Bone Autotransplantation with Extracorporeal Heat-Treatment for Malignant Bone Tumors of Pelvis (골반골의 악성 골종양의 재건술에서 체외 열처리를 이용한 재활용 자가골 이식술 및 인공 관절 치환술을 시행한 3례 보고)

  • Kim, Sae-Hoon;Lee, Sang-Hoon;Cho, Hwan-Sung;Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.115-123
    • /
    • 2003
  • Study Design: A retrospective clinical and radiographic review. Objectives: The purpose of this study was to suggest recycling bone autotransplantation with extracorporeal heat-treatment as one of favorable reconstruction method for malignant bone tumors of pelvis through 3 cases. Summary of Literature Review: There are many biologic and nonbiologic reconstruction method in pelvic reconstruction. Cases: Case 1- A 20-year-old women had chief complaint of right hip and thigh pain started 3 months ago and done curettage and bone cementing at right ilium at other hospital. She had impression of malignant bone tumor and undergone postoperative radiation therapy for 6 cycles. After that she was referred to our hospital and undergone wide excision of right ilium and recycling bone autotransplantation with extracorporeal heat-treatment at 132 degree celsius for 2 minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (ABG$^{(R)}$). There was no evidence of distant metastasis and revealed well-differentiated osteosarcoma on postoperative pathology. Neither adjuvant nor neoadjuvant chemotherapy were done. Case 2- A 56-year-old women who suffered right thigh pain for 3 months was detected radiologic abnormality at right pelvis. After incisional biopsy, osteosarcoma was diagnosed. We had undergone wide excision of right ilium and recycling bone autotransplantation with extracorporeal low heat-treatment at 65 degree celsius for 30minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (ABG$^{(R)}$). There was no evidence of distant metastasis and revealed high-grade osteosacoma which was fibroblastic type on postoperative pathology. Adjuvant chemotherapy (HDMTX, ADR, CDDP) was done immediate after wound healing was completed. Case 3- A 46-year-old women was incidently found mass at left ilium which was suspected chondrosarcoma. We had undergone wide excision of left ilium and recycling bone autotransplantation with extracorporeal low heat-treatment at 65 degree celsius for 30minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (Protek$^{(R)}$). There was no evidence of distant metastasis and revealed chondrosarcoma which was graded II/III on postoperative pathology. Results: Oncologic and functional outcome at final follow-up were for case 1, final follow-up time was 7 years, is no evidence of disease and functional score is 53% according to Ennecking et al. During follow-up, evidence of radiologic union was at about 1 and 6 months after operation. The case had breakage of pelvic reconstruction plate and some resorption of autotransplated bone, but no symptom present. For case 2, final follow-up was 3 years and 6 months, is no evidence of disease and functional score is 60%. For case 3, final follow-up was 7 months, no evidence of disease and functional score is 63% which is improving state. Discussion: 3 cases which were undergone recycling bone autotransplantation with extracorporeal heat-treatment and total hip replacement arthroplasty had relatively successful oncologic and functional outcome. Taking account that difficulty in using allograft in Korea this method is thoght to be one of the useful way to reconstruct pelvis after resection of primary malignant bone tumor of the pelvis.

  • PDF

A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY (구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구)

  • Kim, Il-Kyu;Park, Seung-Hoon;Jang, Keum-Soo;Yang, Jung-Eun;Jang, Jae-Won;Sasikala, Balaraman
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.451-458
    • /
    • 2009
  • Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.

Maxillary Distraction Osteogenesis Using $TS-MD^{(R)}$ (Trans-sinusoidal Maxillary distractor) on Cleft Patients (Trans-sinusoidal maxillary distractor($TS-MD^{(R)}$)를 이용한 구순구개열 환자에서의 상악골 골신장술)

  • Paeng, Jun-Young;Lee, Il-Gu;Myoung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choe, Jin-Yeong;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.8 no.2
    • /
    • pp.71-79
    • /
    • 2005
  • Purpose: Maxillary hypoplasia is a common developmental problem of cleft lip and palate. Fair results with distraction osteogenesis have been reported especially when these patients need a large amount of maxillary advancement, instead of orthognathic surgery. The purpose of this study is to evaluate the clinical results with a relatively new distractor, $TS-MD^{(R)}$ (Trans-sinusoidal maxillary distractor, KLS Martin, Tuttlingen, Germany) which was used for the advancement of the maxilla in the cleft patients. Patients and Method: Distraction osteogenesis using $TS-MD^{(R)}$ was performed for four CLP patients (three males and one female) who had maxillary hypoplasia. All patients were over 16 years old. As three patients showed mandibular prognathism as well, bilateral sagittal split ramus osteotomy for mandibular setback was performed at the same time. After consolidation periods of 4 to 12 weeks, the distraction devices were removed and miniplates were placed for simultaneous internal fixation. Results: Three patients showed a large amount of incisal overbite but one patient did not have sufficient maxillary advancement. Le Fort I osteotomy, maxillary advancement and internal fixation should have been performed for the patient when removing the distraction devices. Different from the $clinician{\box}s$ expectation, the amount of maxillary advancement using $TS-MD^{(R)}$ was not sufficient, although the device has rigid mechanical property. Rotation of maxilla during distraction forward and downward was also observed. Conclusion: Even though the maxillary advancement with $TS-MD^{(R)}$ device could be achieved, the clinical control of some characteristics related with the device was necessary. More clinical studies on $TS-MD^{(R)}$ should be performed.

  • PDF

Treatment of Open Proximal Humerus Fracture by Gunshot (총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 -)

  • Kim, Sung-Jae;Lee, Jae-Hoo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose: To consider the proper management of proximal humerus fracture on gunshot wounds. Materials and Methods: A 28-year-old male patient, who sustained a gunshot injury on the left arm 5 days ago, was admitted through the emergency department. Although he underwent an emergency surgery (bullet fragment removal and debridement), there remained bullet fragments around the proximal humerus fracture site. The wound seemed to be infected and a partial dehiscence occurred. No neurologic deficit was noted. Immediate exploration and debridement were performed, and an external fixator was applied to restore the anatomical alignment and manage the wounds. Intravenous antibiotics were administered. On the 9th postoperative day, wound debridement was done again, and cement beads mixed with antibiotics were inserted. After two weeks, the external fixator was removed, and the pin sites were closed after debridement. One week later, the open reduction and internal fixation with locking compression plate and screws were done. Result: At 3 months after the internal fixation, the bone union was obtained with satisfactory alignment of the humerus. Conclusion: The severity of the soft tissue injury influences the fracture management plan. Further, the risk on lead toxicity should be considered.

Metastatic Pathologic Fractures in Lower Extremities Treated with the Locking Plate (잠김 금속판을 이용한 하지의 전이성 병적 골절에 대한 치료)

  • Seo, Chang-Young;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.80-86
    • /
    • 2010
  • Purpose: The skeleton is commonly affected by metastatic cancer. The purpose of this study was to evaluate the results of treating metastatic pathologic fractures in lower extremities using locking plates. Materials and Methods: Between 2004 and 2010, we evaluated 12 patients (13 cases) of metastatic pathologic fractures in lower extremities, treated with the locking plate. Mean patient age was 62.2 years (range, 50-81 years), the locations of the fractures were; proximal femur in 2 cases, femoral mid-shaft in 3, distal femur in 3, proximal tibia in 4, and distal tibia in 1 case. The interval to wheelchair ambulation, pain relief and complications were evaluated. Additionally, we assessed operation time and postoperative blood loss. Results: Mean time from operation to wheelchair ambulation was 3.2 days (range, 1-6 days). Mean VAS scores improved from a preoperative score of 8.1 points (range, 7-9 points) to a score of 2.7 points (range, 2-4 points) at 1 week postoperatively. No early complications associated with surgery were encountered. Mean operation time was 88.4 minutes (range, 70-105 minutes), and mean postoperative blood loss was 246.5 ml (range, 130-320 ml). Conclusion: Internal fixation of metastatic pathologic fractures using a locking plate in the lower extremity can be an effective treatment option in the meta- or diaphyseal area of long bones with massive bony destruction or poor bone stock by offering early ambulation, pain relief and low postoperative complications.