• Title/Summary/Keyword: Internal fault

Search Result 248, Processing Time 0.027 seconds

A Consideration on the Causes of 22.9kV Cable Terminal Burning Accident (22.9kV 케이블 단말 부위 소손 사고의 원인에 관한 고찰)

  • Shim, Hun
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.2
    • /
    • pp.7-12
    • /
    • 2022
  • The main cause of cable accidents is the accelerated deterioration of the cable itself or internal and external electrical, mechanical, chemical, thermal, moisture intrusion, etc., which reduces insulation performance and causes insulation breakdown, leading to cable accidents. Insulation deterioration can occur even when there is no change in the appearance of the cable, so there is a difficulty in preventing cable accidents due to insulation deterioration. Since cable accidents can occur in areas with poor insulation due to the effects of overvoltage and overcurrent, it is necessary to comprehensively analyze transformers and circuit breakers, and ground faults caused by phase-to-phase imbalance. Ground fault accidents due to insulation breakdown of cables can occur due to defects in the cable itself and poor cable construction, as well as operational influences, arcs during operation of electrical equipment (switchers, circuit breakers, etc.). analysis is needed. This study intends to examine the causes of cable accidents through analysis of cable accidents that occurred in a manufacturing factory.

A Report on Gneiss Dome in the Hongseong Area, Southwestern Margin of the Gyeonggi Massif (경기육괴 남서 연변부 홍성지역에 발달하는 편마암 돔에 대한 보고)

  • Park, Seung-Ik;Kim, Sung Won
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.315-323
    • /
    • 2016
  • This study reports a gneiss dome in the Hongseong area, southwestern margin of the Gyeonggi massif. This gneiss dome, named here as 'Oseosan dome' because it is located around the Oseosan, the highest peak along the western coastal area, is composed mainly of the Neoproterozoic to Paleozoic ortho- and paragneiss, mafic metavolcanic rock, and metadolerite. Migmatization affected these rock units, in which leucocratic(granitic) materials derived from anatexis frequently occur as patch and vein parallel to or cutting through internal foliation. The Oseosan dome shows overall concentric geometry and outward-dipping internal foliation, but also partly complicatedly changeable or inward-dipping foliation. Taking available petrological and geochronological data into account, the Oseosan dome is interpreted to be exhumed quickly into the upper crustal level during the Late Triassic, accompanied in part with anatexis and granite intrusion. In addition, extensional shear zone intruded by the Late Triassic synkinematic granite and sedimentary basin have been reported around the Oseosan dome. These evidences possibly suggest that the Oseosan dome formed in closely associated with the Late Triassic extensional movement and diapiric flow. Alternatively, 1) thrust- or reverse fault-related doming or 2) interference between independent folds during structural inversion of the Late Traissic to Middle Jurassic sedimentary basin can be also considered as dome-forming process. However, considering the northern limb of the Oseosan dome, cutting by the Late Traissic granite, and the southern limb, cutting by contractional fault reactivated after the Middle Jurassic, it is likely that the domal structure formed during or prior to the Late Triassic.

Two-dimensional Analysis of MT Data across Northern Victoria, Australia (호주 북부 Victoria주 MT 탐사 자료의 2차원 해석)

  • Lee, Seong-Kon;Lee, Tae-Jong;Uchida, Toshihiro;Park, In-Hwa;Song, Yoon-Ho;Cull, Jim
    • Geophysics and Geophysical Exploration
    • /
    • v.13 no.4
    • /
    • pp.407-415
    • /
    • 2010
  • MT soundings were carried out in 2008, in northern Victoria, Australia, as a continuing collaboration research of 2007 between Republic of Korea, Australia, and Japan. The main purpose of this research is to investigate electrical conductivity structure and thus help understanding of tectonic structure in central Victoria, which is believed to be closely linked to mineralization and magmatic processes of this region. The survey area is located in western Lachlan Fold Belts, which is the part of Tasman Fold Belts in southeastern Australia. An MT profile of 2008 is almost parallel to the one of 2007 and approximately 50 km away. The 2D inversion result of MT data also shows that the position of conductivity discontinuity near surface are well matched with the positions of major faults, such as Avoca Fault, which is the structural boundary between Stawell and Bendigo Zones, and Heathcote Fault Zone, which marks the boundary between Bendigo and Melbourne Zones. It is also confirmed from resistivity image that internal faults in Bendigo Zone are in listric form, which is implied to be formed by structural shortening during compressional orogenic activity in Silurian.

Cause of Rockfall at Natural Monument Pohang Daljeon-ri Columnar Joint (천연기념물 포항 달전리 주상절리의 낙석 발생원인)

  • Kim, Jae Hwan;Kong, Dal-Yong
    • Economic and Environmental Geology
    • /
    • v.55 no.5
    • /
    • pp.497-510
    • /
    • 2022
  • Monthly monitoring, 3D scan survey, and electrical resistivity survey were conducted from January 2018 to August 2022 to identify the cause of rockfall occurring in Daljeon-ri Columnar Joint (Natural Monument No. 415), Pohang. A total of 3,231 rocks fell from the columnar joint over the past 5 years, and 1,521 (47%) of the falling rocks were below 20 cm in length, 978 (30.3%) of 20-30 cm, and 732 (22.7%) of rocks over 30 cm. While the number of rockfalls by year has decreased since 2018, the frequency of rockfalls bigger than 30 cm tends to increase. Large-scale rockfalls occurred mainly during the thawing season (March-April) and the rainy season (June-July), and the analysis of the relationship between cumulative rainfall and rockfall occurrence showed that cumulative rainfall for 3 to 4 days is also closely related to the occurrence of rockfall. Smectite and illite, which are expansible clay minerals, were observed in XRD analysis of the slope material (filling minerals) in the columnar joint, and the presence of a fault fracture zone was confirmed in the electrical resistivity survey. In addition, the confirmed fault fracture zone and the maximum erosion point analyzed through 3D precision measurement coincided with the main rockfall occurrence point observed by the BTC-6PXD camera. Therefore, the main cause of rockfall at Daljeon-ri columnar joint in Pohang is a combination of internal factors (development of fault fracture zones and joints, weathering of rocks, presence of expansive clay minerals) and external factors (precipitation, rapid thawing phenomenon), resulting in large-scale rockfall. Meanwhile, it was also confirmed that the Pohang-Gyeongju earthquake, which was continuously raised, was not the main cause.

Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock (전철 탑재형 피뢰기의 모듈설계 및 성능평가기술)

  • Cho, H.G.;Kim, S.S.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Design and Performance Evaluation of Surge Arrester for Loading in Railway Rolling Stock (전철 탑재용 피뢰기의 설계 및 성능평가)

  • Cho, H.G.;Han, S.W.;Lee, U.Y.;Kim, S.S.;Chang, T.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.74-77
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock. pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Strain demand prediction of buried steel pipeline at strike-slip fault crossings: A surrogate model approach

  • Xie, Junyao;Zhang, Lu;Zheng, Qian;Liu, Xiaoben;Dubljevic, Stevan;Zhang, Hong
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.109-122
    • /
    • 2021
  • Significant progress in the oil and gas industry advances the application of pipeline into an intelligent era, which poses rigorous requirements on pipeline safety, reliability, and maintainability, especially when crossing seismic zones. In general, strike-slip faults are prone to induce large deformation leading to local buckling and global rupture eventually. To evaluate the performance and safety of pipelines in this situation, numerical simulations are proved to be a relatively accurate and reliable technique based on the built-in physical models and advanced grid technology. However, the computational cost is prohibitive, so one has to wait for a long time to attain a calculation result for complex large-scale pipelines. In this manuscript, an efficient and accurate surrogate model based on machine learning is proposed for strain demand prediction of buried X80 pipelines subjected to strike-slip faults. Specifically, the support vector regression model serves as a surrogate model to learn the high-dimensional nonlinear relationship which maps multiple input variables, including pipe geometries, internal pressures, and strike-slip displacements, to output variables (namely tensile strains and compressive strains). The effectiveness and efficiency of the proposed method are validated by numerical studies considering different effects caused by structural sizes, internal pressure, and strike-slip movements.

External and Internal Morphological Standard of original plants and herbal states in Pogostemonis and Agastachis Herba (광곽향(廣藿香)과 토곽향(土藿香)의 외부(外部) 및 내부형태연구)

  • Kim, Hong-Jun;Choi, Jeong;Ju, Young-Sung
    • Korean Journal of Oriental Medicine
    • /
    • v.12 no.2 s.17
    • /
    • pp.75-83
    • /
    • 2006
  • Pogostemonis and Agastachis Herba are the whole of Pogostemon cablin (BLANCO) BENTH or Agastache rugosa (FISCHER et MEYER) O. KUNTZE (family Labiatae) which is produced in all part of Korea and China. This drug is used for removing dampness by means of aromatics in oriental medicine. The standard formula of this drug is important from the viewpoint of the quality control. A characteristic discrimination of internal and external morphological standard in original plants and herbal states of Pogostemonis and Agastachis Herba are as follows. 1. The external characteristics: Pogostemon cablin has hairs and brown-like in stem, elliptical fruit. In the other hand, Agastache rugosa has no hairs and red-like in stem, obovatic trigone fruit. 2. The physical characteristics: Pogostemon cablin is gray in whole, has hairs in stem and numerous hairs of ash in leaf. In the other hand, Agastache rugosa is yellow-green in whole, has no hairs in stem. Specially the latter has deep-green colour and numerous hairs presenting mostly at lower epidermis in leaf. 3. The physical characteristics in currents: Pogostemon cablin is brown, has hairs and round-like stem. In the other hand, Agastache rugosa is green or yellow-green, has no hairs and tetragon in stem. 4. The internal characteristics: Pogostemon cablin has progressed spongy tissue in epidermal cell of leaf and many rank of epidermal cell in stem. In other hand, Agastache rugosa has 1 rank palisade tissue in leaf and few rank of epidermal cell in stem. In the external shape, it was possible that herbs were distinguished according to artificial classification and that same genus-degree of relatedness among herbs could be distinguished by more precise and active observation. In the shape of real herbs, I compared current herbs in market with original herbs which were just collected or were on the course of drying. In addition, it was possible that the internal shape could be identified by using microscope after butanol series. Though it was impossible to make distinction of herbs which are not current in my search contents, this search contents will be a standard for applying herbs in the future. An Additional standard establishment including physiochemical reaction and gene research is required in order to supplement the fault of this search.

  • PDF

Modified Current Differential Relay for Transformer Protection Unaffected by Remanent flux (잔류자속에 무관한 변압기 보호용 수정전류차동 계전기)

  • 강용철;김은숙
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.9
    • /
    • pp.500-506
    • /
    • 2004
  • This paper proposes a modified current differential relay for transformer protection unaffected by the remanent flux. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. To cope with the remanent flux, before saturation, the relay calculates the core-loss current and uses it to modify the measured differential current. When the core then enters saturation, the initial value of the flux is obtained by inserting the modified differential current at the start of saturation into the magnetization cure. Thereafter, the actual core flux is then derived and used in conjunction with the magnetization curve to calculate the magnetizing current. A modified differential current is then derived that compensates for the core-loss and magnetizing currents. The performance of the proposed differential relay was compared against a conventional differential relay. Results indicate that the modified relay remained stable during severe magnetic inrush and over-excitation because the exciting current was successfully compensated. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. The relay discriminates magnetic inrush and over-excitation from an internal fault and is not affected by the level of remanent flux.

A Study on the Improvement of the Domestic Maintenance Capability Development System of Military for Overseas Maintenance Items through the Case Study of Intermittent Failure of an Avionics (항전계통 간헐결함 사례 분석을 통한 군의 해외 정비품 국내정비능력 개발제도 개선방안 고찰)

  • Lee, Hoyong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.2
    • /
    • pp.68-75
    • /
    • 2018
  • A flare from an Air Force fighter was abnormally dispensed during the landing. To determine the cause of the abnormal dispensing, fracture analysis, signal analysis and reproduction experiments based on physics of failures were performed. The primary cause of the failure was analyzed to be due to an intermittent fault of an internal circuit card in the AN/ALE-40 chaff/flare dispenser by a broken lid of a capacitor, and the root cause which had derived the primary cause was considered to be an improper handling during the domestic maintenance which were changed from the overseas maintenance due to the DMSMS problem. Therefore, the overall process of the maintenance capability development system was reviewed and alternative ways that considers maintenance error decision aid(MEDA) for system improvement were suggested to prevent further failures.