• Title/Summary/Keyword: Internal clearance

Search Result 139, Processing Time 0.022 seconds

Selection of Internal Clearance for Automotive Wheel Bearings Considering an Assembling Procedure (조립과정을 고려한 차륜용 베어링의 내부틈새 선정)

  • 현준수;안태길;김성근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.51-57
    • /
    • 2000
  • An automotive wheel bearing is one of the most important components to guarantee the service life of a passenger car. The endurance lift of a bearing is affected by many parameters such as material properties, heat treatment, lubrication conditions, temperature, loading conditions, geometry, internal clearance and so on. Under the same geometry and loading conditions, the internal clearance is the most effective parameters on the endurance lift of a bearing. Generally, bearings have the longest lift with a little negative internal clearance. But it is very difficult to measure and modify the internal clearance after a wheel bearing is assembled. In this paper, we analyze the effect of an assembling procedure on the clearance of wheel bearings and suggest a method to determine optimal clearance for automotive wheel bearings by selecting initial bearing clearance.

  • PDF

FE-analysis of Shrink Fits and Internal Clearance for Ball Bearing of Machine Tool (공작기계용 볼 베어링의 억지끼워맞춤과 내부틈새변화에 관한 해석적 연구)

  • Kim, Woong;Lee, Choon-Man;Hwang, Young-Kug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.135-141
    • /
    • 2009
  • The bearing clearance is influenced by shrink fit and thermal expansion during operation. The designer must take into account the reduction of clearance after installation to the interference fits, and thermal expansion must be considered. The purpose of this study is to grasp the internal clearance variation and behavior of a bearing which is a deep connected with fatigue life of bearing and performance of spindle through FEM(Finite Element Method). Finite element analysis is performed by using commercial code ANSYS according to variation of thermal condition and rotational speeds. This paper presents correct negative internal clearance according to temperature during operation. Furthermore, interrelation between thermal expansion and contraction are presented to maintain adequate contact force for three type of spindle system (HSK-A60, HSK-40E, HSK-32E). The influence of the centrifugal force and Internal clearance variation of bearing is studied to operating rotational speed.

A Case Report on the Clearance of Vancomycin-Resistant Enterococcus Colonization in a Patient with Traumatic Subarachnoid Hemorrhage and Subdural Hematoma Treated with Hwanglyeonhaedok-tang (황련해독탕 투여 후 Vancomycin-resistant Enterococcus 집락이 해제된 외상성 지주막하출혈 및 경막하혈종 환자 증례보고 1례)

  • Chae, Han-nah;Lee, Ji-eun;Shim, Sang-song;Shin, Sun-ho;Shin, Yong-jeen
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.502-507
    • /
    • 2020
  • This study aimed to investigate the effect of Hwanglyeonhaedok-tang on the clearance of vancomycin-resistant Enterococcus (VRE) colonization in a patient with traumatic subarachnoid hemorrhage and subdural hematoma. A 73-year-old man who was diagnosed with traumatic subarachnoid hemorrhage and subdural hematoma with isolation of VRE colonization was administered Hwanglyeonhaedok-tang and followed up with a rectal swab VRE culture every week. After treatment with Hwanglyeonhaedok-tang, VRE colonization was no longer detected. This case report proved that Hwanglyeonhaedok-tang could be an effective treatment for clearance of VRE colonization in a patient with traumatic subarachnoid hemorrhage and subdural hematoma.

Observation of Castability of Dental DLP 3D Printer Materials (치과용 DLP 3D Printer 가공체의 주조성 관찰)

  • Song, Joon-boo;Park, Yu-jin;Choi, Sung-min
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.255-262
    • /
    • 2019
  • Purpose: Recently, the production technology of dental prosthesis using 3D Printer workpeices has been developed. However, the lack of information on the work processes and casting techniques of materials for 3D printing casting is expected to require research. Therefore, in this study, we intend to cast a Dental DLP 3D Printer workpiece, which is being commercialized, to identify its appearance and internal clearance, and to observe its castability. Methods: Castability of the 3D Printer workpiece was evaluated. The specimen is prepared in a cylindrical shape and in a 1 mm thick coping shape. The control specimen is made of wax and the experimental specimen is made of resin using two types of 3D printers. After casting, the appearance of the casting body was observed and the internal clearance of the coping was measured. Results: RP1 and RP2, cylindrical specimens, were partially cast or fin. When coping-type specimens were measured before casting, the internal clearance of PE2 was more accurate than that of PC and PE1. When coping-type specimens were measured after casting, CE1 was the most accurate in occlusal clearance and CE2n was the most accurate in axial clearance. Conclusion: 1. Exterior observations of the casting body indicated casting defects and fins. 2. Internal clearance observations show that the occlusal clearance of the castings is larger after casting, and the axial clearance of the castings is smaller after casting. 3. It is judged that the RP2 specimen is more likely to be applied for casting than the RP1 specimen.

Glomerular Filtration Rate Determined in Conjunction with $^{99m}TC-DTPA$ Routine Renal Scintigraphy (통상적 $^{99m}TC-DTPA$ 신장스캔을 이용한 GFR 측정)

  • Yi, Gang-Wook;Han, Jin-Suk;Chung, June-Key;Lee, Myung-Chul;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.49-54
    • /
    • 1989
  • Many previously described nuclear medicine procedures to assess glomerular filtration rate (GFR) required numerous blood samples obtained over a period of several hours to determine plasma concentrations of the injected radiopharmaceuticals. And other indirect methods of determining renal clearance have some problems due to individual variations in volume of distribution of the radionuclides used. Rescently reported Jackson's method have the great advantages that is a direct measurement method requiring less than 40 min of imaging time and single blood sampling. And it correctly accounts for individual variations in volume of distribution of the radiopharmaceuticals and can be done with routine renal scintrgraphy. We measured $^{99m}Tc-DTPA$ renal clearance with Jackson's method during the routine $^{99m}Tc-DTPA$ renal scintigraphy in 63 patients admitted to department of internal medicine in SNUH. In 23 cases among 63 patients creatinine clearence was accounted simultaneously. The range of $Cl_{DPDA}$ was from 19.9 ml/min to 170 ml/min and the correlation of $Cl_{DPDA}$ and creatinine clearance was discribed by Y=16.2570+0.7852 X($X=Cl_{DTPA}$ Y=creatinine clearance). And the correlation coefficient r was 0.88. We concluded that $^{99m}Tc-DTPA$ renal clearance measurement with Jackson's method was clinically useful to account GFR that can be done with routine $^{99m}Tc-DTPA$ renal scintigraphy simultaneously.

  • PDF

Study for the Increase of Micro Regenerative Pump Head

  • Horiguchi, Hironori;Wakiya, Keisuke;Tsujimoto, Yoshinobu;Sakagami, Masaaki;Tanaka, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.3
    • /
    • pp.189-196
    • /
    • 2009
  • The effect of inlet and outlet blade angles on a micro regenerative pump head was examined in experiments. The pump head was little increased by changing the blade angles compared with the original pump with the inlet and outlet blade angles of 0 degree. The effect of the axial clearance between the impeller and the casing on the pump head was also examined. The head was increased largely by decreasing the axial clearance. The computation of the internal flow was performed to clarify the cause of the increase of the pump head due to the decrease of the clearance. The local flow rate in the casing decreased as the leakage flow rate through the axial clearance decreased due to the decrease of the clearance. It was found that the larger head in the smaller clearance was just caused by the smaller local flow rate in the casing. In the case of the smaller clearance, the smaller local flow rate caused the smaller circumferential velocity near the front and rear sides of the impeller. This caused the increase of the angular momentum in the casing and the head.

Safety Evaluation of Clearance of Radioactive Metal Waste After Decommissioning of NPP (원전해체후 규제해제 대상 금속폐기물에 대한 자체처분 안전성 평가)

  • Choi, Young-Hwan;Ko, Jae-Hun;Lee, Dong-Gyu;Hwang, Young-Hwan;Lee, Mi-Hyun;Lee, Ji-Hoon;Hong, Sang-Bum
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.291-303
    • /
    • 2020
  • The Kori-Unit 1 nuclear power plant, which is scheduled to be decommissioned after permanent shutdown, is expected to generate large amounts of various types of radioactive waste during the decommissioning process. Among these, nuclear reactors and internal structures have high levels of radioactivity and the dismantled structure must have the proper size and weight on the primary side. During decommissioning, it is important to prepare an appropriate and efficient disposal method through analysis of the disposal status and the legal restrictions on wastes generated from the reactors and internal structures. Nuclear reactors and internal structures generate radioactive wastes of various levels, such as medium, very low, and clearance. A radiation evaluation indicates that wastes in the clearance level are generated in the reactor head and upper head insulation. In this study, a clearance waste safety evaluation was conducted using the RESRAD-RECYCLE code, which is a safety evaluation code, based on the activation evaluation results for the clearance level wastes. The clearance scenario for the target radioactive waste was selected and the maximum individual and collective exposure doses at the time of clearance were calculated to determine whether the clearance criteria limit prescribed by the Nuclear Safety Act was satisfied. The evaluation results indicated that the doses were significantly low, and the clearance criteria were satisfied. Based on the safety assessment results, an appropriate metal recycle and disposal method were suggested for clearance, which are the subject of the deregulation of internal structures of nuclear power plant.

EFFECT OF DIETARY PANAX GINSENGS ON THE RATE OF THE BLOOD ETHANOL CLEARANCE (식이성(食餌性) 인삼(人蔘)이 백서혈액(白鼠血液) ethanol의 청소율(淸掃率)에 관(關)한 효과(效果))

  • Chang, Ie-Soo
    • The Journal of Internal Korean Medicine
    • /
    • v.1 no.1
    • /
    • pp.92-97
    • /
    • 1976
  • Upon feeding dried Ginseng to rats of either low-protein or high protein diet ethanol was administered intraperitoneally and disappearance rate blood alcohol was enzymatically measure. In terms of residual blood alcohol after a time lapse of 3.5 hours between intraperitonial administration and blood withdrawal neither ginseng nor ginseng plus 40% casein did improve the rate, of alcohol clearance but sexual difference was clearly demonstrated in favor of female rats. In the case of blood withdrawn only 2 hours after intraperitoneal injection of alcohol, the tendency of female superiority in alcohol clearance rate is demonstrated when a comparison is made among the groups fed with ginseng and this was particularly true is groups of rats fed with basal diet plus 1 percent ginseng residual blood ethanol being 15.4 mg/ml vs. 8.8 mg/ml. Liver homogenate alcohol dehydrogenase activity measured in terms of residual ethanol content after in vitro reaction on which a known amount of alcohol was added clearly demonstrated a male superiority in alcohol clearance.

  • PDF

A Study on the Optimum Shrink-fit for High Speed Ball Bearing of Machine Tool (공작기계용 고속 볼베어링의 최적 끼워맞춤에 관한 연구)

  • Kim, Woong;Lee, Choon-Man;Hwang, Young-Kug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.9
    • /
    • pp.94-102
    • /
    • 2010
  • The spindle is the main component in machine tools. To develop high speed machine tools, a lot of studies have been carried out for high speed spindle. Bearing is very important part in spindle. The bearing clearance is influenced by shrink fit and thermal expansion during operation. The designer must take into account the reduction of shrink fits. The aims of this study are to grasp the shrink fits and behavior of a bearing which is a deeply connected with fatigue life of bearing and performance of spindle through FEM(Finite Element Method). This paper proposed optimum value of shrink fit considering deformation of spindle and stress of fitting area using design of experiments. Thus, the proposed formula can be used to obtain bearing internal clearance.