• Title/Summary/Keyword: Internal Location

Search Result 694, Processing Time 0.026 seconds

A Study on Internal Morphology and Physicochemical Patterns of Salvia miltiorrhiza Bunge Root According to Cultivation Regions in China (중국 재배지역별 단삼의 내부형태 및 이화학적 패턴 연구)

  • Goo, Bup-Seoug;Yoo, Ji-Hyun;Kil, Ki-Jung
    • The Korea Journal of Herbology
    • /
    • v.34 no.1
    • /
    • pp.33-42
    • /
    • 2019
  • Objectives : This study aimed to be used as basic data for obtaining excellent quality of Salvia miltiorrhiza (SM) root. Methods : SM cultivated in Anhui Bozou, Henan, Shandong, Henan Wenxian, Zhejiang, Hebei, Liaoning, Shanxi, Shaanxi Shangluo, Sichuan Zhongjiang, Sichuan Minyang and Jiangsu in China were gathered and its internal morphology and physicochemical patterns were analyzed. Results : Cross-section of sang plants according to cultivated regions in China showed that cork layers consisted of cells with four to six layers, cortex width was wide, and phloem was semilunar-shaped. Although there are forms layers, yet boundary was vague. It was observed that eight to ten vascular bundles were arranged in wooden parts in all directions and as a single line of vascular was distributed nearby form layers as it nears to the center. Tanshinon IIA identified a spot in the same location with standard product near by Rf 0.9 in the test identifying TLC of SM according to cultivated areas in China. The largest amount was 0.535% identified in Shandong and the lowest amount of 0.05% in Hebei. Salvianolic acid B identified a spot in the same location with standard product near by Rf 0.7 in the test identifying TLC of SM according to cultivated areas in China. The largest amount was 2.72% identified in Liaoning and the lowest amount of 0.825% in Jiangsu. Conclusions : The results are assumed to be used as basic data for obtaining excellent quality of SM oriental medical hers and distinguishing authentic or fake herbs.

Comparison of diagnostic performances of slow-pull suction and standard suction in endoscopic ultrasound-guided fine needle biopsy for gastrointestinal subepithelial tumors

  • Joon Seop Lee;Chang Min Cho;Yong Hwan Kwon;An Na Seo;Han Ik Bae;Man-Hoon Han
    • Clinical Endoscopy
    • /
    • v.55 no.5
    • /
    • pp.637-644
    • /
    • 2022
  • Background/Aims: Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is integral to the diagnosis of gastrointestinal (GI) subepithelial tumors (SETs). The impact of different EUS-FNB tissue sampling techniques on specimen adequacy and diagnostic accuracy in SETs has not been fully evaluated. This study aimed to compare the diagnostic outcomes of slow-pull (SP) and standard suction (SS) in patients with GI SETs. Methods: In this retrospective comparative study, 54 patients were enrolled. Medical records were reviewed for location and size of the target lesion, FNB needle type/size, technical order, specimen adequacy, diagnostic yield, and adverse events. The acquisition rate of adequate specimens and diagnostic accuracy were compared according to EUS-FNB techniques. Results: The mean lesion size was 42.6±36.4 mm, and most patients were diagnosed with GI stromal tumor (75.9%). The overall diagnostic accuracies of the SP and SS techniques were 83.3% and 81.5%, respectively (p=0.800). The rates of obtaining adequate core tissue were 79.6% and 75.9%, respectively (p=0.799). No significant clinical factors affected the rate of obtaining adequate core tissue, including lesion location and size, FNB needle size, and final diagnosis. Conclusions: SP and SS had comparable diagnostic accuracies and adequate core tissue acquisition for GI SETs via EUS-FNB.

The anatomical study of internal mammary perforators (내유방혈관 관통지에 대한 해부학적 연구)

  • Lim, Sung Yoon;Song, Hyun Suk;Pae, Nam Suk;Park, Myong Chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.24-28
    • /
    • 2009
  • Purpose: As a recipient vessel, internal mammary vessels have many advantages for microvascular reconstruction of the breast. But the approach is time consuming and results in large morbidities. However, the perforating branches of the internal mammary vessels can be used to minimize such demerits. The purpose of this cadaver study is to clarify the location and diameter of the perforating branches of internal mammary vessels and to prove they are safe and reliable recipient vessels. Methods: We studied 11 formalin - fixed cadavers and dissected their anterior chests bilaterally. The chests were exposed using midline presternal incisions. We dissected and found all perforators at subfascial planes under loupe magnification. The number, external diameter, and the distance from the midline were measured. Result: The mean external diameter of the arterial perforators was 1.32 mm and the mean external diameter of the venous perforators was 1.48 mm. The largest arterial and venous perforators were most frequently found in the second intercostal space. The mean distance from the midline to the perforator was evaluated; the artery averaged 1.95 cm and the vein averaged 2.08 cm. Conclusion: This study will be helpful when using the internal mammary perforating vessels as a recipient vessel during breast reconstruction.

New Approach for Detecting Leakage of Internal Information; Using Emotional Recognition Technology

  • Lee, Ho-Jae;Park, Min-Woo;Eom, Jung-Ho;Chung, Tai-Myoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.11
    • /
    • pp.4662-4679
    • /
    • 2015
  • Currently, the leakage of internal information has emerged as one of the most significant security concerns in enterprise computing environments. Especially, damage due to internal information leakage by insiders is more serious than that by outsiders because insiders have considerable knowledge of the system's identification and password (ID&P/W), the security system, and the main location of sensitive data. Therefore, many security companies are developing internal data leakage prevention techniques such as data leakage protection (DLP), digital right management (DRM), and system access control, etc. However, these techniques cannot effectively block the leakage of internal information by insiders who have a legitimate access authorization. The security system does not easily detect cases which a legitimate insider changes, deletes, and leaks data stored on the server. Therefore, we focused on the insider as the detection target to address this security weakness. In other words, we switched the detection target from objects (internal information) to subjects (insiders). We concentrated on biometrics signals change when an insider conducts abnormal behavior. When insiders attempt to leak internal information, they appear to display abnormal emotional conditions due to tension, agitation, and anxiety, etc. These conditions can be detected by the changes of biometrics signals such as pulse, temperature, and skin conductivity, etc. We carried out experiments in two ways in order to verify the effectiveness of the emotional recognition technology based on biometrics signals. We analyzed the possibility of internal information leakage detection using an emotional recognition technology based on biometrics signals through experiments.

Two Cases of Inflammatory Pseudotumor in Respiratory System (호흡기계에 발생한 염증성 가성종양 2예)

  • Kim, Jae-Gwon;Jeong, Nak-Yong;Kim, Kwang-Hyun;Kim, Hee-Sun;Lee, Won-Yeon;Yong, Suk-Joong;Shin, Kye-Chul;Yang, Seok-Woo;Jeong, Soon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.3
    • /
    • pp.394-401
    • /
    • 1999
  • Inflammatory pseudotumor is a infrequent, benign tumor that affects at all ages and involves the lung, gastrointestinal tract, and salivary gland. They are the most common, isolated, primary lesion of the lung in children, and usually present as circumscribed, peripheral, parenchymal tumors or endobronchial tumors, which may be usually static or increase slowly in size without causing symptoms. Surgical excision is the treatment of choice because of the location and benign nature of this lesion. The prognosis after resection is excellent. Other therapeutic modalities include radiation and steroid therapy. We experienced two cases of inflammatory pseudotumor of the lung parenchyme and endobronchus. We report these cases with a review of literatures.

  • PDF

A Case of Inflammatory Pseudotumor Completely Resolved by Steroid Therapy (스테로이드 요법으로 완치된 염증성 가종양 1예)

  • Bang, Seung-Ho;Kim, Chi-Hong;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.6
    • /
    • pp.709-713
    • /
    • 1993
  • Inflammatory pseudotumor, also known as plasma cell granuloma, is a rare, benign tumor that affects at all ages and frequently involves the lung, gastrointestinal tract, and salivary gland. They are the most common, isolated, primary lesion of the lung in children less than 16 years of age, and usually present as circumscribed, peripheral, parenchymal tumors, which may be static or increase slowly in size without causing symptoms. Surgical excision is the treatment of choice bacause of the location and benign nature of this lesion. The prognosis after resection is excellent. Adjuvant therapeutic modalities include radiation and steroid therapy. Recently, we experienced a case of inflammatory pseudotumor of the lung, the diagnosis of which was made by percutaneous fine needle aspiration cytology examination. We tried steroid and the lesions of the lung was completely resolved. We report this case with a review of literatures.

  • PDF

Internal Aerodynamic Noise from Quick Opening Throttle Valve (쓰로틀 밸브의 빠른 열림 동작에 의한 내부공력소음)

  • 정철웅;김성태;김재헌;이수갑
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.4
    • /
    • pp.310-318
    • /
    • 2004
  • For many industrial problems originating from aerodynamic noise, noise prediction techniques, reliable and easy to apply, would be of great value to engineers and manufacturers. General algorithm is presented for the prediction of internal flow-induced noise from quick opening throttle valve in an automotive engine. This algorithm is based on the integral formula derived by using the General Green Function, Lighthill's acoustic analogy and Curle's extension of Lighthill's. Novel approach of this algorithm is that the integral formula is so arranged as to predict frequency-domain acoustic signal at any location in a duct by using unsteady flow data in space and time, which can be provided by the Computational Fluid Dynamics Techniques. This semi-analytic model is applied to the prediction of internal aerodynamic noise from a throttle valve in an automotive engine. The predicted noise levels from the throttle valve show good agreement with actual measurements. The results show that the dipole noise is dominant in this phenomena and the origin of noise sources is attributed to the anti-vortex lines formed in the down-stream from a throttle valve. This illustrative computation shows that the current method permits generalized predictions of flow noise generated by bluff bodies and turbulence in flow ducts.

Numerical Analysis on the Behavior of the Earth Tunnel due to Supporting Methods (지보공법에 따른 토사터널의 거동에 관한 수치해석)

  • Kim, Jin-Tae;Park, Byung-Soo;Jeong, Gil-Soo;Yoo, Nam-Jea
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.239-250
    • /
    • 2004
  • Numerical analysis were performed to investigate the stability and internal movement of tunnel located beneath the base of abutment of bridge according to the method of supporting tunnel. Two supporting methods of the multi-staged grouting method with steel pipes and the large diameter of pipe supporting method were used in the centrifuge model tests. The slip form of model lining, specially built to simulate the process of tunnel excavating under the condition of accelerated g-level, was used in the centrifuge model tests. Four centrifuge model tests were performed, changing the supporting methods of the multi-staged grouting method with steel pipes and the large diameter of pipe supporting method and the location of model abutment base of bridge. For internal displacement of tunnel, movements of the crown. The left and the right sides of spring line were measured during the proceeds of excavating tunnel in centrifuge model tests. Test results were compared with numerically estimated values of internal displacement of tunnel by using the commercially available FEM software of PENTAGON-3D. It was found that they were in good agreements and the large diameter of pipe supporting method was more stable than the multi-staged grouting method with steel pipes with respect to the internal movement of tunnel.

  • PDF

NUMERICAL SIMULATION OF THREE-DIMENSIONAL INTERNAL WAVES USING THE FDS SCHEME ON THE HCIB METHOD (FDS 기법과 HCIB법을 이용한 3차원 내면파 수치 모사)

  • Shin, Sang-Mook
    • Journal of computational fluids engineering
    • /
    • v.17 no.1
    • /
    • pp.8-15
    • /
    • 2012
  • A code developed using the flux-difference splitting scheme on the hybrid Cartesian/immersed boundary method is applied to simulate three-dimensional internal waves. The material interface is regarded as a moving contact discontinuity and is captured on the basis of mass conservation without any additional treatment across the interface. Inviscid fluxes are estimated using the flux-difference splitting scheme for incompressible fluids of different density. The hybrid Cartesian/immersed boundary method is used to enforce the boundary condition for a moving three-dimensional body. Immersed boundary nodes are identified within an instantaneous fluid domain on the basis of edges crossing a boundary. The dependent variables are reconstructed at the immersed boundary nodes along local normal lines to provide the boundary condition for a discretized flow problem. The internal waves are simulated, which are generated by an pitching ellipsoid near an material interface. The effects of density ratio and location of the ellipsoid on internal waves are compared.

Complications of Endotracheal Stent in Three Dogs with Tracheal Collapse (기관허탈이 있는 개들에서 기관 내 Stent 장착 후 나타난 합병증 3례)

  • Seo, Kyoung-Won;Lee, Young-Heun;Chang, Jin-Hwa;Hwang, Cheol-Yong;Yoon, Jung-Hee;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.457-461
    • /
    • 2010
  • Three dogs were presented with signs of recurrence of coughing, dyspnea and difficulty of barking after endotracheal stent placement. On the basis of history taking, physical examination, laboratory tests and radiography, complications of endotracheal stent were suspected. Dog 1 had unfitted stent diameter (stent diameter is larger than tracheal diameter) and getting disentangled of proximal tracheal stent wire. Dog 2 was suspected a foreign body reaction. Dog 3 had the migration of stent caudally. Based on these cases, the veterinarian should accurately evaluate the indicated patients before endotracheal stent and has to select the appropriate stent (diameter, length and location) to prevent complications after endotracheal stent and concern the regular follow-ups to assure proper endotracheal stent placement.