• Title/Summary/Keyword: Internal Gain

Search Result 373, Processing Time 0.022 seconds

Determinants of Short-Term Weight Gain Following Surgical Treatment for Craniopharyngioma in Adults

  • Hong, A Ram;Kim, Jung Hee;Park, Seung Shin;Kong, Sung Hye;Choi, Hyung Jin;Kim, Yong Hwy;Shin, Chan Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.439-448
    • /
    • 2022
  • Objective : Craniopharyngiomas (CPs) are associated with hypothalamic damage that causes hypothalamic obesity, however, the mechanisms underlying CP-related postoperative weight gain remain debatable. This study aimed to elucidate whether the major determinant of postoperative weight gain in patients with CP is hypothalamic injury or steroid replacement therapy. Methods : We included 48 adult patients with CP (age ≥18 years) who underwent transsphenoidal surgery between 2010 and 2018 in a single tertiary center, and whose body weight was measured pre- and postoperatively (<120 days after the surgery). We recruited 144 age- and body mass index-matched patients with non-functioning pituitary adenoma (NFPA) as controls. Results : Patients with CP experienced greater postoperative weight gain than patients with NFPA (3.0±5.1 vs. 0.1±3.6 kg, p<0.001). The prevalence of postoperative steroid use was significantly higher in patients with CP than in those with NFPA (89.6% vs. 34.0%, p<0.001). Steroid replacement therapy and CP were associated with postoperative weight gain after adjusting for covariates in overall patients (p=0.032 and 0.007, respectively). In subgroup analysis with postoperative steroid users, weight gain was significantly greater in patients with CP (n=43, 0.96±0.25 kg/month) than in patients with NFPA (n=49, 0.26±0.23 kg/month) even after adjusting for the daily steroid dose (p=0.048). Conclusion : Patients with CP experience greater postoperative weight gain than those with NFPA. Hypothalamic damage itself as well as steroid replacement may contribute to the postoperative weight gain in patients with CP.

The Gain Enhancement of 1.8V CMOS Self-bias High-speed Differential Amplifier by the Parallel Connection Method (병렬연결법에 의한 1.8V CMOS Self-bias 고속 차동증폭기의 이득 개선)

  • Bang, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1888-1892
    • /
    • 2008
  • In this paper, a new parallel CMOS self-bias differential amplifier is designed to use in high-speed analog signal processing circuits. The designed parallel CMOS self-bias differential amplifier is developed by using internal biasing circuits and the complement gain stages which are parallel connected. And also, the parallel architecture of the designed parallel CMOS self-bias differential amplifier can improve the gain and gain-bandwidth product of the typical CMOS self-bias differential amplifier. With 1.8V $0.8{\mu}m$ CMOS process parameter, the results of HSPICE show that the designed parallel CMOS self-bias differential amplifier has a dc gain and a gain-bandwidth product of 64 dB and 49 MHz respectively.

Thermal Modeling of Quasi-Adiabatic Room and Lighting Fixture for Estimation of Internal Heat Gain by Luminaires (조명기구를 통한 내부획득열 추정을 위한 고단열실 및 조명기구의 열적 모델링)

  • Park, He-Rie;Choi, Eun-Hyeok;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.5
    • /
    • pp.1-12
    • /
    • 2012
  • In order to reduce energy consumption and greenhouse gas emission in building domain, thermal insulation of building is being enhanced. In a well insulated and tightened environment, internal heat gain caused by solar radiation, luminaires, electronic appliances and metabolism can be more important to thermal condition of building. This paper presents mathematical/physical models of quasi-adiabtic room and lighting fixtures using heat balance equation and thermal-electric analogy to quantify and modelize the heat gain due to luminaires. Experimental results are used to identify thermal parameters of theoretical models. And simulation results of models using Matlab/Simulink are conducted to verify the models and to investigate the thermal effect of lighting fixtures into quasi-adiabatic room.

The operating characteristics of strain-compensated 1.3$\mu$m GaInAsP/InP uncooled-LD with the structure of multiple quantum well and separate confinement heterostructure layers (응력완화 1.3$\mu$m GaInAsP/InP uncooled-LD의 다중양자우물층과 SCH층 구조에 따른 동작 특성)

  • 조호성;박경현;이정기;장동훈;김정수;박기성;박철순;김홍만;편광의
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.7
    • /
    • pp.185-197
    • /
    • 1996
  • We have adopted the strain compensated PBH(planar buried heterostructure) - LD in which the MQW active layer consisted of 1.4% compressively strained GainAsP (E$_{g}$ = 0.905eV) wells and 0.7% tensile strained GaInAsP(E$_{g}$ = 1.107eV) barriers grown by metal organic vapor phase epitaxy (MOVPE). We hav einvestigated effects of number of wells and the structure of the separate confinement heterostructure (SCH) layer in the strain-compensated MQW-PBH-LD. The threshold current, the external quantum efficiency, the transparency current density J$_{o}$, and the gain constant .beta. have been evaluated for uncoated MQW-PBH-LD. As the number of wells increases, the internal quantum efficiency and the transparency current density decreases, whereas the gain contant increases. The small width of the SCH layer shows the large internal quantum efficiency. The small internal loss and the large gain constant have been obtained by inserting the large bandgap SCH layer.

  • PDF

IPI feeding structure for the gain improvement of IFA (IFA 이득 향상을 위한 IPI 급전 구조)

  • Oh, Kyu-Jong;Son, Tae-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.817-823
    • /
    • 2010
  • Design of IPI feeding structure affecting the antenna gain improvement of mobile phone was investigated. IPI feeder which based on the T matching theory increase line current for internal antenna such as IFA. So IPI feeder makes higher radiation resistance, and also increases the gain with increasing radiation efficiency. To verify IPI feeding effect, feeder is applied to conventional CDMA/DCS dual band IFA. Measurement shows that IPI-IFA has 0.5 ~ 1.4[dBi] higher gain than conventional IFA at CDMA/DCS band. Resonant frequency did not change.

The Impact of Internal heat gain on heating and Cooling Load in Curtain Wall Office Buildings (커튼월 사무소용 건물에서 실내발열이 냉난방 부하에 미치는 영향)

  • Kim, Jeong-Yoon;Yook, In-Soo;Nam, Hyun-Jin;Lee, Jin-Sung;Kim, Jae-Min;Cho, Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.925-930
    • /
    • 2008
  • As office automation appliances and communication equipments are adopted in office buildings, internal heat gains increase gradually. When making simulation model, internal heat gains are usually set up with standard values or ignored. Therefore, the impact of the internal heat gains has been ignored or not been focused although it is recognised as significant contributor to heating/cooling load of buildings. This study focused on the impact of internal heat gains on curtain wall buildings. the amount and schedules of heat internal gains profiles not only affect the profiles of heating/cooling loads, but also make impact on reducing the effectiveness of high performance glazing systems. It is important to identify internal heat gains profiles before considering the installation of high performance glazing systems.

  • PDF

Design of the IPI-IFA using the Inverted PI Feeder (역 파이 급전 방식을 적용한 IPI-IFA)

  • Oh, Kyu-Jong;Son, Tae-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.5
    • /
    • pp.662-668
    • /
    • 2009
  • Design of IPI(Inverted PI) feeding internal antenna for the gain improvement of mobile phone was proposed. IPI feeding structure affects on both low radiation resistance of antenna and increase current for the internal antenna such as IFA(Inverted F Antenna). By these facts, antenna fed by IPI can get the gain improvement with increasing radiation efficiency. For the verification, we applied IPI feeding structure to conventional quad band IFA. Measurement shows that IPI-IFA has 0.3~2.0[dB] higher gain than conventional IFA on GSM/DCS/USPCS/WCDMA band.

  • PDF

A Study on Change in Window Transmitted Solar and the Resultant Wall Surface Convective Heat Gain with Regard to Slat Reflectance of External and Internal Blinds (실내·외 블라인드의 Slat 반사율에 따라 창호 일사투과량 및 그에 따른 벽체 대류열획득량 분석)

  • Hyun, In-Tak;Lee, Jae-Ho;Yoon, Yeo-Beom;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.565-571
    • /
    • 2014
  • Nowadays, to make buildings light weight and aesthetically pleasing, curtain wall structure are commonly used. Therefore, window to wall ratio is increasing, which has caused cooling and heating load in crease in buildings as well. This phenomenon has negative impact from energy point of view. This paper analyzes window and wall convective heat gain when the slat reflectance of external and internal blinds are changed for the better understanding of the fundamentals behind the phenomena. It was observed that, if slat reflectance is increased, window transmitted solar increases and convection heat rate is clearly affected. Among six surfaces including four walls, ceiling and floor, maximum convection heat rate occurs on the south wall in summer. On the other hand, ceiling and floor showed the lowest convection heat gain, since they are shared by adjacent floors.

An Analysis on Characteristics and the Development of Estimation Model of Internal Heat Gain from Appliances in Apartment Units (공동주택 단위세대의 기기발열 특성 분석 및 추정모델 개발)

  • Lee, Soo-Jin;Jin, Hye-Sun;Kim, Sung-Im;Lim, Han-Young;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.10
    • /
    • pp.19-26
    • /
    • 2018
  • The purpose of this study was to analyze characteristics and to develop estimation model of IHG(Internal Heat Gain) from appliance in domestic apartment units. To do this, it was defined the source of IHG from appliance and the calculation method through the case study of international and domestic codes. And the equipment related datum such possession, usage or not, etc were collected through field survey in apartment units, and the appliances' electricity consumption were measured separately from overall electricity consumption. Annual electricity consumption value were calculated with field survey datum and appliances' electricity consumption measurement datum, and then IHG value was calculated by applying PHPP v9 method. And it was conducted correlation analysis between IHG value and the area for exclusive use, the number of occupants, and then the IHG from applianace estimation model was deducted with regression analysis. Finally, it was analyzed the present level and of the domestic code(The Building Energy Efficiency Rating System) comparing with the value of estimation model, and the various international codes(HERS, Building America, SAP).

Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building (노후 학교건물의 창호 교체에 따른 부하분석)

  • Lee, Ye Ji;Kim, Joo Wook;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.