Influence of Ge addition on AC loss and micro-structure in $Nb_{3}Sn$ wires (Ge를 첨가한 Nb$_3$Sn 초전도 선에서의 교류손실 및 미세조직 변화)

  • 하도우;이남진;오상수;하홍수;송규정;권영길;류강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.104-107
    • /
    • 2001
  • In order to investigate the effect of Ge addition to the Cu matrix on the microstructure and the critical current density, four kinds of internal tin processed Nb$_3$Sn strands with pure Cu and Cu 0.2, 0.4, 0.6 wt % Ge alloys were drawn to 0.8 mm diameter. The microstructure and critical current of internal tin processed Nb$_3$Sn wires that were heat treated at temperatures ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$ for 240h were investigated. The Ge addition to the matrix did not make workability worse. A Ge rich layer in the Cu-Ge matrix suppressed the growth of the Nb$_3$Sn layer and promoted grain coarsening. The greater the Ge content in the matrix, the lower the net Jc result after Nb$_3$sn reaction heat treatment. There was no significant variation in Jc observed with heat treatment temperature ranging from 68$0^{\circ}C$ to 74$0^{\circ}C$. The values of AC loss of Ge added wires were decreased to 40 % compare with no addition wire. Low AC loss was due to segregation of Ge rich layer in the Cu-Ge matrix. If Ge added wire with thin Nb filaments were fabricated, slow diffusion rate of Sn would be overcome and decreased AC loss that is weak Point of internal tin method.

  • PDF

A Study on the Creep Fracture Life of Al 7075 Alloy(II) (Al 7075 합금의 크리이프 파단수명에 관한 연구(II))

  • 강대민
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.4
    • /
    • pp.29-41
    • /
    • 1994
  • High temperature tensiles tests, steady state creep tests, internal stress tests and creep rupture tests using Al 7075 alloy were performed over the temperature range of 9$0^{\circ}C$~50$0^{\circ}C$ and stress range of 0.64~17.2(kgf/$\textrm{mm}^2$) in order to investigate the creep behavior and predict creep rupture life From the apparent activation energy Qc and the applied stress exponent n measured, at the temperature range of 9$0^{\circ}C$~l2$0^{\circ}C$, the creep deformation seemed to be controlled by cross slip. On the other hand at the temperature of 20$0^{\circ}C$~23$0^{\circ}C$ the creep deformation seemed to be controlled by dislocation climb but at 47$0^{\circ}C$~50$0^{\circ}C$, by diffusion creep. And the rupture life(t$_{f}$) might be represented by anthermal process attributed to the difference of the applied stress dependence of Internal stress and the ratio of the Internal stress to the applied stress, the thermal activated process attributied to the temperature dependence of the internal stress. Also the ratio between stress dependence of primary creep rate and that of minimum creep rate was measured 0.46, the minimum creep rate is expected to be appromately obtained from master creep curve including the relationship primary creep rate and minumum creep rate. Finally the relationship new rupture parameter and logarithmic stress was represented with including the ratio between the dependence of primary creep rate and that of minimum creep rate, using the new rupture parameter the rupture life predition is exactly expected.d.

  • PDF

Factors Associated with the Discrepancy between Exercise Capacity and Airflow Limitation in Patients with Chronic Obstructive Pulmonary Disease

  • Tae Hoon Kim;I Re Heo;Na Young Kim;Joo Hun Park;Hee-Young Yoon;Ji Ye Jung;Seung Won Ra;Ki-Suck Jung;Kwang Ha Yoo;Ho Cheol Kim
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.2
    • /
    • pp.155-164
    • /
    • 2024
  • Background: Exercise capacity is associated with lung function decline in chronic obstructive pulmonary disease (COPD) patients, but a discrepancy between exercise capacity and airflow limitation exists. This study aimed to explore factors contributing to this discrepancy in COPD patients. Methods: Data for this prospective study were obtained from the Korean COPD Subgroup Study. The exercise capacity and airflow limitation were assessed using the 6-minute walk distance (6-MWD; m) and forced expiratory volume in 1 second (FEV1). Participants were divided into four groups: FEV1 >50%+6-MWD >350, FEV1 >50%+6-MWD ≤350, FEV1 ≤50%+6-MWD >350, and FEV1 ≤50%+6-MWD ≤350 and their clinical characteristics were compared. Results: A total of 883 patients (male:female, 822:61; mean age, 68.3±7.97 years) were enrolled. Among 591 patients with FEV1 >50%, 242 were in the 6-MWD ≤350 group, and among 292 patients with FEV1 ≤50%, 185 were in the 6-MWD >350 group. The multiple regression analyses revealed that male sex (odds ratio [OR], 8.779; 95% confidence interval [CI], 1.539 to 50.087; p=0.014), current smoking status (OR, 0.355; 95% CI, 0.178 to 0.709; p=0.003), and hemoglobin levels (OR, 1.332; 95% CI, 1.077 to 1.648; p=0.008) were significantly associated with discrepancies in exercise capacity and airflow limitation in patients with FEV1 >50%. Meanwhile, in patients with FEV1 ≤50%, diffusion capacity of carbon monoxide (OR, 0.945; 95% CI, 0.912 to 0.979; p=0.002) was significantly associated with discrepancies between exercise capacity and airflow limitation. Conclusion: The exercise capacity of COPD patients may be influenced by factors other than airflow limitation, so these aspects should be considered when assessing and treating patients.

Impact of Internal/External Diffusion on Gasification Reaction Rate Analysis of Coal Char in High Temperatures and Elevated pressures (고온/고압 조건에서의 석탄 촤 내부 및 외부 가스화 반응효과)

  • Kim, Gyeong-Min;Kim, Jin-Ho;Lisandy, Kevin Yohanes;Kim, Ryang-Gyoon;Kim, Gyu-Bo;Jeon, Chung-Hwan
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.4
    • /
    • pp.23-29
    • /
    • 2016
  • Reactivity of gasification defined by bouardard reaction is critical parameter in efficiency of the gasifier. In this study, char reactivity of the gasification was derived from the experiments using the intrinsic reaction kinetics model. Pressurized wire mesh heating reactor (PWMR) can produce high temperature and high pressure conditions up to 50 atm and 1750 K, respectively and PWMR was designed to evaluate the intrinsic reaction kinetics of $CO_2$ gasification. In this study, Kideco and KCH (sub-bituminous Indonesian coal) were pulverized and converted into char. Experiments used the PWMR were conducted and the conditions of the temperature and pressure were 1373~1673 K, 1~40 atm. To distinguish the pressure effect from high pressurized condition, internal and external effectiveness factors were considered. Finally, the intrinsic kinetics of the Kideco and KCH coal char were derived from $n^{th}$ order reaction rate equations.

Magnetic Resonance Imaging and Pathologic Correlation of Cerebral Fat Embolism using Oleic Acid

  • Park, Byung-Rae
    • Biomedical Science Letters
    • /
    • v.10 no.2
    • /
    • pp.115-120
    • /
    • 2004
  • To investigate the correlation between the magnetic resonance imaging (MRI) of cerebral fat embolism that is induced by injecting oleic acid into 10 cats, and a pathologic diagnosis. Using a microcatheter, 30 ${mu}ell$ of oleic acid was injected into the internal carotid artery of 10 cats. MR T2-weighted image (T2WI), diffusion-weighted image (DWI) and Gadolinium-enhanced T1-weighted image (Gd-enhanced T1WI) were obtained after 30 minutes and 2 hours of embolization. After 30 minutes of the embolization, lesions of very high signal intensity were detected by T2WI in 6 cats, and of slightly high signal intensity in 2 cats; in the remaining 2 cats, signal intensity was normal. DWI showed lesions of very high intensity in 9 cats and of slightly high intensity in one cat. According to the findings of light microscopic examination, infarcted lesions mainly involved the gray matter, but also some white matter. A magnetic resonance imaging diagnosis for cerebral fat embolism that was induced by oleic acid through the internal carotid artery in cats showed high signal intensity on the T2WI and the DWI within an initial 2 hours, and with a well enhancement on the Gd-enhanced T1WI. Considering cellular edema, cerebrovascular injury and extracellular space widening, we assumed pathologically that cytotoxic and vasogenic edema exists at the same time.

  • PDF

The Influence of Paper Stock Type on Characteristics of Sizing (지료조성에 따른 종이의 사이징 특성)

  • Cheong Sang Jin;Kim Bong Yong
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.37 no.2 s.110
    • /
    • pp.11-20
    • /
    • 2005
  • This study was carried out to investigate the influence of paper stock type and heat treatment on sizing effect. Various types of pulps were used to make handsheets sized internally with AKD(alkyl ketene dimer) and externally with CMC(carboxyl methyl cellulose). Most of the handsheets were treated with heat by dry oven $(100^{\circ}C,\;30min)$ to evaluate the effect of heat treatment on sizing development. Internal sizing development of newsprint was very bad, but the effect of heat treatment was much higher than those of NBKP, BCTMP. In case of surface sizing, newsprint was more effective compared to the other pulps. Considering above mentioned results, it seems that internal sizing slows down water into paper by molecular diffusion much more than capillary penetration, but surface sizing slows down capillary penetration. With regard to density, a higher thickness sheets showed high heat treatment effect on sizing, therefore it assumed that heat treatment effect on sizing had very close relationship with sheet density.

Quantitation of Flurbiprofen in Isopropyl Myristate by High Performance Liquid Chromatography (고속액체크로마토그래피를 이용한 미리스틴산이소프로필증 플루르비프로펜의 정량)

  • Kim, Hyun;Chi, Sang-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.1
    • /
    • pp.63-68
    • /
    • 1992
  • An HPLC procedure with UV detection has been developed for the quantitation of flurbiprofen released into isopropyl myristate used as the receptor phase in an in vitro membraneless drug diffusion cell. The drug and the internal standard (oxaprozin) were extracted from isopropyl myristate with a mixture of dimethylsulfoxide:methanol:water (2:1:1) and quantitated using a reverse phase $C_{18}$ column. The chromatograms were completely free from interfering peaks, and the relative retention times of flurbiprofen and the internal standard were 4.9 and 6.8 min, respectively. Calibration plots were linear over the concentration range of $1-200\;{\mu}g/ml$ of flurbiprofen with correlation coefficients, all higher than 0.99. The mean intra-day precision and accuracy among three replicate sets of the assay in a day were 4.26 and 4.52%, respectively, whereas the mean inter-day precision and accuracy were 3.35 and 3.64%, respectively. The mean recovery of the drug was 92.5% over the calibration range. The method was simple, reliable and accurate for the quantitation of flurbiprofen in unpurified isopropyl myristate.

  • PDF

Evaluation of water permeability of forward osmosis membranes using osmotically driven membrane test (랩스케일 정삼투실험을 통한 정삼투막의 수투과도 평가)

  • Lee, Junseo;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.4
    • /
    • pp.417-425
    • /
    • 2016
  • Desalination is a key technology to overcome water shortage problem in a near future. High energy consumption is an Achilles' heel in desalination technology. Osmotically driven membrane processes like forward osmosis(FO) was introduced to address this energy issue. Characterizing membrane properties such as water permeability(A), salt permeability(B), and the resistance to salt diffusion within the support layer($K_{ICP}$) are very important to predict the performance of scaled-up FO processes. Currently, most of researches reported that the water permeability of FO membrane was measured by reverse osmosis(RO) type test. Permeating direction of RO and FO are different and RO test needs hydraulic pressure so that several problems can be occurred(i.e. membrane deformation, compaction and effect of concentration polarization). This study focuses on measuring water permeability of FO membrane by FO type test results in various experimental conditions. A statistical approach was developed to evaluate the three FO membrane properties(A, B, and $K_{ICP}$) and it predicted test result by the internal and external concentration polarization model.

Inadvertent Self-Detachment of Solitaire AB Stent during the Mechanical Thrombectomy for Recanalization of Acute Ischemic Stroke : Lessons Learned from the Removal of Stent via Surgical Embolectomy

  • Kang, Dong-Hun;Park, Jaechan;Hwang, Yang-Ha;Kim, Yong-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.360-363
    • /
    • 2013
  • We recently experienced self-detachment of the Solitaire stent during mechanical thrombectomy of acute ischemic stroke. Then, we tried to remove the detached stent and to recanalize the occlusion, but failed with endovascular means. The following diffusion weighted image MRI revealed no significant increase in infarction size, therefore, we performed surgical removal of the stent to rescue the patient and to elucidate the reason why the self-detachment occurred. Based upon the operative findings, the stent grabbed the main thrombi but inadvertently detached at a severely tortuous, acutely angled, and circumferentially calcified segment of the internal carotid artery. Postoperative angiography demonstrated complete recanalization of the internal carotid artery. The patient's neurological deficits gradually improved, and the modified Rankin scale score was 2 at three months after surgery. In the retrospective case review, bone window images of the baseline computed tomography (CT) scan corresponded to the operative findings. According to this finding, we hypothesized that bone window images of a baseline CT scan can play a role in terms of anticipating difficult stent retrieval before the procedure.

Seven-year Survival Rate of On-line Hemodiafiltration

  • Yoon, Jung-Hwan;Kim, Nam-Ho
    • Biomedical Science Letters
    • /
    • v.25 no.1
    • /
    • pp.32-39
    • /
    • 2019
  • Conventional high-flux hemodialysis (HD) is not as good as normal kidney function. Morbidity and mortality rates of patients receiving HD are still very high. To increase mid-to-large molecule clearance by combining diffusion and convection, on-line hemodiafiltration (HDF) is required. The objective of this study was to compare long-term survival rate of patients treated with on-line HDF to those who received conventional high-flux HD by reviewing data from Chonnam National University Hospital (CNUH). We selected patients who attended the 'CUNH dialysis center' and agreed to participate in the study. Overall, 40 patients with ESRD switched from high flux HD to on-line HDF or started on-line HDF from August 2007 to December 2009. Additionally, a total of 42 patients receiving conventional high-flux HD during the same period were enrolled. We then reviewed long-term survival rate of patients receiving on-line HDF over the next seven years. When we compared survival rates for seven years, the survival rate of the group receiving on-line HDF was 65% (26/40) while that of the group receiving the conventional high-flux HD was 54.8% (23/42). Although the number of patients was small to see survival difference clearly by one specific dialysis modality, there was somewhat difference in survival rate between the two groups. Indicators such as anemia, calcium-phosphate metabolism, nutritional status, treatment adequacy, and hospitalization were also improved in the group receiving HDF. Overall, results of our study showed beneficial effects of on-line HDF on clinical outcomes and survival in chronic HD patients.