• Title/Summary/Keyword: Internal Defects

Search Result 513, Processing Time 0.025 seconds

Astudy of internal defects and their effects in $CaF_2$ single crystals (형석단결정의 내부결함 및 그 영향에 관한 연구)

  • Seo, Soo-Hyung;Joo, Kyoung;Auh, Keun-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.3
    • /
    • pp.419-423
    • /
    • 1998
  • The internal defects in $(CaF_2)$ single crystal were characterized by the observation of optical microscopy, the element analysis and the transmittance analysis. In bubble and negative crystal which are composed to crystal plane of (100) and (111), the spread negative crystal in $(CaF_2)$ crystal gave an effect of low transmittance. The precipitates formed in bubble as internal cavities were analyzed by using WDX. Violet colored-crystal had higher a dislocation density than non-colored crystal, and the atomic ratio between Ca and F changed by poor F ion. In this result, we could determine indirectly that violet color was occurred by poor F ion.

  • PDF

THE EFFECT OF SPRUE DESIGN ON THE MARGINAL REPRODUCIBILITY OF CAST TITANIUM CROWNS (주입선 형태가 티타늄 주조관의 변연재현성에 미치는 영향)

  • Park Jae-Kyoung;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.352-364
    • /
    • 2002
  • There has been a great interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However the high melting temperature and chemical reactivity of titanium necessitates casting systems different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new developments in Ti casting systems, inadequate mold filling and internal porosity are frequently observed casting defects. Therefore, the study on the fabrication technique including sprue design to solve these casting defects is still necessary. In this study to evaluate the effect of sprue design on the castability of simulated cast titanium crowns, 10 cylindrical cast crowns for each group with four different sprue design(Single group. Double group, Runner bar group. Reservoir group) were fabricated. An impression of the entire casting margin was made and cut at $90^{\circ}$ intervals, and the sections were photographed in a microscope at $100{\times}$ magnification to record marginal discrepancy. The internal porosities of the cast crowns were disclosed by radiographs. Within the limits of this study. the following conclusions were drawn. 1. The overall mean marginal discrepancies for each group were as follows: Double group, $43.65{\mu}m$; Reservoir group, $50.27{\mu}m$; Single group, $54.17{\mu}m$; Runner bar group, $58.90{\mu}m$ (p<0.05). 2. The mean of marginal discrepancies for wax patterns was $10.65{\mu}m$. 3 The numbers of internal porosity showed the most in Runner bar group followed by Single group, Reservoir group, and Double group.

Simulations for Internal Defect Inspection Using Laser Generated Ultrasonic Wave in Ablation Regime (어블레이션 영역 레이저 초음파의 시뮬레이션과 내부결함 검사)

  • Kim, Jin-Gyum;Choi, Sungho;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.226-232
    • /
    • 2014
  • In the present study, the characteristics of laser ultrasound in the ablation regime are investigated using simulations and experiments. The laser ultrasonic technique has been recognized as a noncontact method in the field of nondestructive tests (NDTs). In hostile environments (such as hot temperatures), this method has various advantages over the conventional contact ultrasonic method. In particular, in the ablation regime, the laser ultrasonic technique is suitable for inspecting internal defects because of the high amplitude and directivity of the longitudinal wave. In this paper, a simulation model for laser ultrasound in the ablation regime was developed. This model was subsequently applied to a defective specimen using the B-scan method to locate defects. Finally, we performed an experimental test to verify the simulation results. Consequently, the simulation demonstrated good agreement with the experimental test.

A Study on the single crystal growth of the optic-grade $LiTaO_3$ as a electro-optic materials

  • Kim, B.k.;J.K. Yoon
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.526-526
    • /
    • 1996
  • The single crystal of LiTaO3 is well known eletro-optic material as well as the piezoelectric one applied to SAW filter. LiTaO3 has large electro-optic effects, so applied to optical switch, acosto-optic deflector, and optical memory device using photorefractive effects. The crystal growth of SAW-grade LiTaO3 has been studied many aspects, but there is no detail research about optic-grade crystal growth. The conditions of optic-grade LiTaO3 single crystal are as below. The optical transmittance must be over 75%, and axial and radial concentratiom uniformity below 1%. The variation of Curie temperature depending on Li/Ta ratio must be also below 2$^{\circ}C$ and no internal no internal cracks and defects. Because of the limitation of crystal quality, the growing of optic-grade LiTaO3 single crystal is very difficult compared with the growing of SAW-grade. In this research, upper conditions of optic-grade single crystal was investigated after growing of 1 inch diameter and 1.5 inch length LiTaO3 single crystal having no internal cracks and defects using Czochralski method. Curie temperature was determined with DSC and measuring capacitance and lattice parameter was calculated about the grown crystal and ceramic powder samples of various Li/Ta ratio. The result of Tc variation was below 1.2$^{\circ}C$ all over the grown crystal, so it is confirmed that LiTaO3 was grown under congruent melting composition having optical homogeniety. Also, the optical transmittance was about 78%, which was sufficient for optical device.

  • PDF

Side Effects of Orthopedic Products in Veterinary Medicine in South Korea

  • Yun, Taesik;Jung, Soo Yeon;Kang, Kyongmook;Yun, Seon-Jong;Koo, Yoonhoi;Park, Jooyoung;Kim, Ill-Hwa;Kang, Hyun-Gu
    • Journal of Veterinary Clinics
    • /
    • v.39 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • As more veterinary clinics become specialized with the growth of the companion animal market, an increasing number of veterinary clinics perform orthopedic surgery and use orthopedic products, some of which are defective and have side effects. Thus, the present study aimed to prepare fundamental data for the revision and development of manufacturing standards for these products in order to prevent their side effects. We conducted a survey targeting veterinary clinics as consumers and medical device companies as suppliers. Veterinary clinics were surveyed via offline and online methods; 320 clinics that offered orthopedic surgery and approximately 4,000 veterinary clinics that were registered in the Korean Veterinary Medical Association were targeted, and 153 veterinary clinics responded to the survey. The survey for medical device companies, was performed online, targeting 29 companies; 14 companies responded. The number of side effects of orthopedic products was higher in animal orthopedic products than in those for human use. Many consumers tended to suspect that side effects were caused by product defects. To resolve side effects after using orthopedic products, consumers mostly underwent reoperation. Meanwhile, some severe cases proceeded to legal disputes. Similarly, medical device companies, or the suppliers, responded that most side effects occurred in veterinary orthopedic products and that product defects and mistakes in use were the causes. As for most of the follow-up actions for side effects, these companies either reported the issue to those in charge or analyzed and resolved the issues themselves. Therefore, to develop quality products, suppliers should be provided with clear standards for the production, and information disclosure and a report system for side effects should be particularly established to gain consumers' trust regarding the safety of these products.

Endoscopic Intervention for Anastomotic Leakage After Gastrectomy

  • Ji Yoon Kim;Hyunsoo Chung
    • Journal of Gastric Cancer
    • /
    • v.24 no.1
    • /
    • pp.108-121
    • /
    • 2024
  • Anastomotic leaks and fistulas are significant complications of gastric surgery that potentially lead to increased postoperative morbidity and mortality. Surgical intervention is reserved for cases with severe symptoms or hemodynamic instability; however, surgery carries a higher risk of complications. With advancements in endoscopic treatment options, endoscopic approaches have emerged as the primary choice for managing these complications. Endoscopic clipping is a traditional method comprising 2 main categories: through-the-scope clips and over-the-scope clips. Through-the-scope clips are user friendly and adaptable to various clinical scenarios, whereas over-the-scope clips can close larger defects. Another promising approach is endoscopic stent insertion, which has shown a high success rate for leak closure, although vigilant monitoring is required to monitor stent migration. Infection control is essential in post-surgical leakage cases, and endoscopic internal drainage provides a relatively safe and noninvasive means to manage fluids, contributing to infection control and wound healing promotion. Endoscopic suturing offers full-thickness wound closure, but requires additional training and endoscopic versatility. As a promising tool, endoscopic vacuum therapy potentially surpasses stent therapy by draining inflammatory materials and closing defects. Furthermore, the use of tissue sealants, such as fibrin glue and cyanoacrylate, has been reported to be effective in selected situations. The choice of endoscopic device should be tailored to individual cases and specific patient conditions, with careful consideration of the nature of the defect. Further extensive studies involving larger patient populations are required to provide more robust evidence on the efficacy of endoscopic approach in managing post-gastric anastomotic leaks.

Radioisotope Perfusion Lung Scanning in Takayasu's Arteritis (Takayasu 동맥염에서 폐관류스캔에 관한 연구)

  • Park, Seok-Gun;Bom, Hee-Seung;Oh, Yeon-Sang;Han, Jin-Suk;Chung, June-Key;Choi, Sung-Jae;Kim, Byung-Kook;Lee, Jung-Sang;Lee, Young-Woo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.73-78
    • /
    • 1986
  • Of 18 patients with Takayasu's arteritis who underwent $^{99m}Tc-MAA$ (macroaggregated albumin) perfusion luing scanning, 9 (50%) showed perfusion defects. Chest X-rays of them were nonspecific. One patient underwent $^{99m}Tc-DTPA$ radio aerosol inhalation lung scanning simultaneously, which revealed normal. So routine screening radioisotope perfusion lung scanning is helpful to evaluate pulmonary arterial involnmement in Takayasu's arteritis patients. And Takayasu's arteritis should be included in differential diagnosis of pulmonary embolism.

  • PDF

A Study on the Size Evaluation of Disc and Band Type Flaw by Ultrasonic Tandem Testing (초음파(超音波)TANDEM사각법(斜角法)에 의한 원형(圓形) 및 띠형결함(形缺陷)의 크기 평가(評價)에 관한 연구(硏究))

  • Han, E.K.;Eom, H.S.;Kim, J.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.2
    • /
    • pp.12-21
    • /
    • 1986
  • Generally, butt welds with plate thickness $30{\sim}40mm$ are welded with groove angle $40^{\circ},\;60^{\circ},\;70^{\circ}$, etc. In the detection of internal weld defects, oblique testing with single probe has been mainly used. But, recently, in acccordance with enlargement of welded structure, thick plate with 100-200mm are frequently required. Thus I-groove welding method was lately developed and often used. In this case, most frequently generated defects are the lack of weld penetration and incomplete fusion between base metal and welding material. If we would detect by oblique testing with single probe, detecting flaw is occassionally impossible or very underestimated. In this study, the limit for applying tandem method was studied in dise and band type flaws. The estimation of flaw size could be within 10% error compared to real flaws.

  • PDF

A Study on the U-bending of Rectangular Hollow Tube by the Eccentric Extrusion and Bending Process (편심압출굽힘가공법에 의한 사각형 단면을 가진 중공 튜브제품의 U형굽힘가공에 관한 연구)

  • Kim, Jin-Hoon;Jin, In-Tai
    • Transactions of Materials Processing
    • /
    • v.7 no.5
    • /
    • pp.496-504
    • /
    • 1998
  • The eccentric extrusion and bending process for the forming of the curved rectangular hollow tube is newly developed. Generally the bending process of hollow tube is the secondary process followed by the extrusion process of the hollow tube from the round billet. So many defects such as wrinkling and the difference of wall thickness can be happened during the secondary bending process. In order to avoid the defects the new process named as "the eccentric extrusion and bending process" is suggested and applied to the U-bending of rectangular hollow tube. In this paper the kinematically admissible velocity field between the dies surface and the internal plug boundary surface s developed for the curving velocity. By the using of this curving velocity field the curvature of extruded products can be calculated with the parameters such as eccentricity dies length friction constant aspect ratio.

  • PDF

Rail Inspection Using Noncontact Laser Ultrasonics

  • Kim, Nak-Hyeon;Sohn, Hoon;Han, Soon-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.6
    • /
    • pp.696-702
    • /
    • 2012
  • In this study, a noncontact laser ultrasonic system is proposed for rail defect detection. An Nd-Yag pulse laser is used for generation of ultrasonic waves, and the corresponding ultrasonic responses are measured by a laser Doppler vibrometer. For the detection of rail surface damages, the shape of the excitation laser beam is transformed into a line. On the other hand, a point source laser beam is used for the inspection of defects inside a rail head. Then, the interactions of propagating ultrasonic waves with defects are examined using actual rail specimens. Amplitude attenuation was mainly observed for a surface crack, and reflections were most noticeable from an internal damage. Finally, opportunities and challenges associated with real-time rail inspection from a high-speed train are discussed.