• Title/Summary/Keyword: Internal Defect

Search Result 444, Processing Time 0.03 seconds

A RADIOGRAPHIC STUDY OF THE EXPERIMENTAL LESIONS IN THE MAXILLARY SINUS (상악동의 실험병소에 관한 X선학적 연구)

  • Lee Joo Hyun;Hwang Eui Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.115-124
    • /
    • 1994
  • The purpose of this study was to examine the differences in representation of a globular radiopaque mass on the pantomograms and Waters' views and to compare the efficacy of periapical radiograms, pantomograms and Waters' views in detection of defects on the internal walls of the maxillary sinus. This study was performed with dried human skull. For the study of difference of radiopaque mass shadow in the two views, rubber ball with a diameter of 10㎜ was used as the experimental lesion. It was placed successively on the internal wall of the anterior, posterior, medial, lateral walls and floor of the maxillary sinus. To examine the detectability of defects for radiographic techniques, defects were formed in the anterior, posterior, medial, lateral walls, and floor of the maxillary sinus. They were formed with 0.5㎜, 0.75㎜, 1.0㎜, 2.0㎜ and 3.0㎜ sized steel round burs with a slow speed dental handpiece. By subsequently plugging the holes with zinc oxide eugenol paste, radiopaque defects were produced. After that the periapical radiograms, the pantomograms and the Waters' views were taken each and every defect. The obtained results were as follows: 1. Rubber balls placed on each internal wall of the maxillary sinus were correctly depicted on the posterior wall and the floor in case of the pantomogram, and on the anterior wall and the medial wall in case of the Waters' view. 2. On the detectability of defects for each radiographic technique, radiolucent defects were detected in different places for each technique. Periapical radiogram could detect 1.0㎜ defect on the floor of the maxillary sinus, pantomogram could detect 2.0㎜ defect on every internal wall of the maxillary sinus, and Waters' view could detect 3.0㎜ defect on the anterior wall of the maxillary sinus. 3. On the detectability of defects for each radiographic technique, radiopaque defects were detected in different places for each technique. Periapical radiogram could clearly detect 0.5㎜ defect on the floor of the maxillary sinus, pantomogram could detect 0.5㎜ defect on every internal wall of the maxillary sinus, and finally Waters' view could detect 0.5㎜defect on the anterior wall of the maxillary sinus but 0.75㎜ defect on the anterior wall, lateral wall and floor of the maxillary sinus. As the result, the periapical radiogram is the most simple and satisfactory method for investigating in the maxillary sinus. The pantomogram is suitable method for screening of changes in the maxillary sinus. And the Waters' view is available for detect of lesion in the anterior wall of the maxillary sinus. For the purpose of accurate diagnosis and evaluation of lesion in the maxillary sinus, these techniques supplement each other.

  • PDF

Deformation Measurement of Well Thinning Elbow by Using Shearography (전단간섭법을 이용한 감육 곡관부의 변형 계측)

  • Jung, Hyun-Chul;Kim, Koung-Suk;Chang, Ho-Sub;Jung, Sung-Wook;Kang, Ki-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.321-328
    • /
    • 2006
  • In this study, the deformation oi wall thinning elbow is measured and the position of the internal thinning defect is found out by shearography. Shearography is an optical method which has applied to nondestructive testing (NDT) and the strain/stress and deformation analysis. This technique has the merit of the directly measuring the first derivative of displacement with sensitivity which can be adjusted by handling the tilt mirror in the interferometer. In this paper, we tested carbon steel pipe locally wall thinned and loaded internal pressure and the shearography was applied to measure the out-of-plane deformation of wall thinning elbow and to investigate the internal thinning defect of it. From the results, it was confirmed that this technique is proper to the practical application on the pipe line system with internal defect.

Effect of Internal Pressure on the Behavior of Wall Thinned Elbow under In-Plane Bending (In-plane 굽힘 조건에서 감육엘보우 거동에 미치는 내압의 영향)

  • Kim, Jin-Weon;Kim, Tae-Soon;Park, Chi-Yong
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.268-273
    • /
    • 2004
  • This study is conducted to clarify the effect of internal pressure on the deformation and collapse behaviors of wall thinned elbow under in-plane bending moment. Thus the nonlinear three-dmensional finite element analyses were performed to obtain the moment-rotation curve of elbow contatining various wall thinning defects located at intrados and extrados under in-plane bending (closing and opening modes) with internal pressure of $0{\sim}15MPa.$ From the results of analysis, the effect of internal of collapse moment of elbow on the global deformation behavior of wall thinned elbow was discussed, and the dependence of collapse moment of elbow on the magnitude of internal pressure was investigated under different loading mode, defect location, and defect shape.

  • PDF

A study on the Measurement of Internal Defects of Pressure Vessel by using ESPI Methods (ESPI 방법들을 이용한 압력용기 내부 결함 측정에 관한 연구)

  • LEE J.S;Kang Y.J.;Baik S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1803-1807
    • /
    • 2005
  • The pipe which it uses from the nuclear power plant or factory by a long period use and a corrosive action the inside defect occurs on the inside. abstract here. The ESPI method is in order to investigate the laser light in the measurement object it will be able to measure the wide territory whole in once, does not receive an effect in direction of defect not to be, has the strong point it will be able to measure a change of place arrowhead real-time defect. It measured a inside defect of pressure vessel by using Out of plane ESPI and In plane of ESPI. It compared a each method result.

  • PDF

Cor Triatriatum Sinistrum with an Ostium Primum Atrial Septal Defect in a Siamese Cat

  • Choi, Ran;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.518-522
    • /
    • 2008
  • An approximately 8-month-old, 2.61 kg, male Siamese kitten was referred with primary complaints of a 1-week history of respiratory distress, exercise intolerance and dyspnea. Diagnostic studies identified III/VI systolic murmur in the cardiac auscultation, right ventricular enlargement patterns in the electrocardiogram, pleural effusion and right-sided cardiomegaly in the thoracic radiography, and right marked ventricular dilatation, right atrial enlargement, atrial septal defect and abnormal left atrium divided by fibromuscular membrane. Based on these findings, the case was diagnosed as cor triatriatum sinistrum complicated with an ostium primum atrial septal defect. The cat was rescued with furosemide, nitroglycerine, oxygen supplement and fluid removal from pleural cavity.

A study on the Measurement result comparison of Internal Defects of Pressure Vessel by using ESPI Methods and FEM Methods (ESPI를 이용한 압력용기 내부 결함 측정 결과와 유한 요소 법을 이용한 결과 비교에 관한 연구)

  • Lee J.S.;Kang Y.J.;Baik S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.910-913
    • /
    • 2005
  • The pipe which it uses from the nuclear power plant or factory by a long period use and a corrosive action the inside defect occurs on the inside. abstract here. The ESPI method is in order to investigate the laser light in the measurement object it will be able to measure the wide territory whole in once, does not receive an effect in direction of defect not to be. has the strong point it will be able to measure a change of place arrowhead real-time defect. It measured a inside defect of pressure vessel by using ESPI and FEM. It compared a each method result.

  • PDF

Effect of Local Wall Thinning Defect on the Collapse Moment of Elbow (엘보우의 붕괴모멘트에 미치는 국부 감육결함의 영향)

  • Kim, Jin-Weon;Kim, Tae-Soon;Park, Chi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.402-409
    • /
    • 2004
  • The purpose of this study is to investigate the effect of local wall thinning on the collapse of elbow subjected to internal pressure and bending moment. Thus, the nonlinear three-dimensional finite element analyses were performed to obtain the collapse moment of elbow containing various wall thinning defects located at intrados and extrados under two loading modes (closing and opening modes) with internal pressure. From the results of analysis, the effect of wall thinning defect on the global moment-rotation behavior of elbow was discussed, and the dependence of collapse moment of elbow on wall thinning depth, length, and circumferential angle was investigated under different loading mode and defect location.

Right to Left Atrial Septum Defect Compounded with Patent Ductus Arteriosus in a Maltese Dog

  • Ahn, Sung-Taek;Kim, Myung-Jun;Yoon, Won-Kyoung;Suh, Sang-il;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.34 no.2
    • /
    • pp.90-93
    • /
    • 2017
  • A nine-month-old intact female Maltese dog (body weight: 1.5 kg) presented with frequent syncopal episodes (1-2/day), exercise intolerance, and dyspnea. Cardiomegaly with marked dilation of right and left atria along with ascites was indicated on radiography. Tricuspid regurgitant jets (4.36 m/s), pulmonary regurgitant jets (3.4 m/s), left-to-right shunting flow at the ductus arteriosus, and an atrial septal defect were observed on echocardiography. A bubble study with agitated saline found right-to-left shunting at the interatrial septum. Based on diagnostic studies, the dog was diagnosed with right-to-left atrial septum defect (ASD) compounded with patent ductus arteriosus (PDA). The treatment was directed to reduce the pulmonary hypertension, improve cardiac performance, and lower fluid retention. Despite medical treatment for 2 months, the dog died of sudden cardiac arrest. Herein, we describe a very rare case of right-to-left ASD compounded with PDA.

A Study on the Artificial Defect Sensitivity of Fatigue Limit in Austempered Ductile Iron (오스템퍼링처리한 구상흑연주철에서 인공결함에 대한 피로한도 민감도에 관한 연구)

  • Kim, M.G.;Kim, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.3
    • /
    • pp.215-220
    • /
    • 1999
  • Rotary bending fatigue tests were carried out to investigate the artificial defect sensitivity of fatigue limit in annealed and austempered ductile irons. Artificial defect(hole, diameter${\leq}0.4mm$) machined on specimen surface did not bring about an obvious reduction of fatigue limit in austempered ductile iron as compared with annealed. As a result of investigation on $\sqrt{area}$ c which is the critical artificial defect size. $\sqrt{area}$ c of austempered ductile iron is larger than that of annealed. This means that the crack initiation at artificial defect in austempered ductile iron is more difficult in comparison with annealed. In case that the $\sqrt{area}$ c of artificial defect and graphite nodule are same, the rate of crack initiation for graphite nodule is higher than that of artificial defect.

  • PDF