• Title/Summary/Keyword: Intermittent pulse

Search Result 40, Processing Time 0.021 seconds

The oriental medical study about the arrythmia detected on the radial pulses and the result of ECG (촌관척(寸關尺)부의 검측한 부정맥과 electrocardiographic 결과와의 한의학적 검토)

  • Lyu, Heui-Yeong;Heo, Eun-Jung;Kim, Ji-Hyon;Yun, Jung-Mi;Jeon, Seong-Ha
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.1
    • /
    • pp.81-106
    • /
    • 2008
  • The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒 )type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using EKG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the EKG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血 ) had downward aptitude of QRS wave, the wave which had both Cold(寒) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈) is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). From these results, we will have to study about EKG which using in tests of change of Parkinsons disease.

  • PDF

Effects of Stimulation Conditions and Waveforms on Muscle Contractile Characteristics

  • Song Tongjin;Khang Gon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.111-116
    • /
    • 2005
  • This study was designed to apply the stimulation system developed in our laboratory to investigate how the stimulation conditions affect the muscle contractile characteristics in the isometric condition as well as during the FES standing/walking. Four paraplegic and ten healthy subjects participated in this study, and their knee extensors were voluntary contracted or electrically stimulated to measure the muscle force and the fatigue index for different waveforms of the pulse train. We also investigated different combinations of the electrode positions during standing/walking. It was confirmed that continuous and high-frequency stimulation causes faster fatigue than intermittent and low-frequency stimulation. Fatigue resistance was higher around the optimal muscle length than at a stretched position in healthy subjects, whereas the opposite was observed in paralyzed subjects. The paired t-test results with the level of significance at 0.01 indicated that the sinusoidal waveform generated the largest torque among the four typical waveforms. Although statistically not very significant, the sinusoidal waveform also generated, in general, the highest fatigue resistance at an intensity level below the supramaximal stimulation. One of the paraplegic subject who participated in the standing/walking program can now stand up for 1 minute and 50 seconds with the knee extensors, and walk for about 5 minutes at the speed of 12m/sec.

${\ll}$영추(靈樞).근결(根結)${\gg}$ 에 대한 연구(硏究)

  • Geum Gyeong-Su;Jeong Heon-Yeong;Kim Nam-Su;Jang Jong-Yeol
    • Journal of Korean Medical classics
    • /
    • v.13 no.1
    • /
    • pp.74-101
    • /
    • 2000
  • Geungyul(根結) means roots and nodes of meridians. If human body gets damaged by energy which each seasons has, the meridians get some troubles. Healing for symptom, meridians consist of root, stay, follow, inpouring and node of acupuncture points should be in harmony. 1. This chapter explain roots and node parts of each meridian, acupuncture points name and root, stay, follow, inpouring of acupuncture points which in arm and leg of three Yin and Yang. 2. The opening, closing, axis function, the symptom, and the needling of both meridians of Yin and Yang are explained. 3. The method that predicts the rise-and-fall of visceral energy and the time of death by using an order of pulse and intermittent pulse is explained. 4. It is explained that since the physical condition of the rich and the poor are different, the method using a needling for each person to be healed, such as the deep-and-shallow and the quick-and-slow, are different. 5. It is explained that the excess and the deficiency in the energy of shape should be considered when a acupuncture is given.

  • PDF

Sensorless Scheme for Interior Permanent Magnet Synchronous Motors with a Wide Speed Control Range

  • Hong, Chan-Hee;Lee, Ju;Lee, Dong-Myung
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2173-2181
    • /
    • 2016
  • Permanent magnet synchronous motors (PMSMs) have higher torque and superior output power per volume than other types of AC motors. They are commonly used for applications that require a large output power and a wide range of speed. For precise control of PMSMs, knowing the accurate position of the rotor is essential, and normally position sensors such as a resolver or an encoder are employed. On the other hand, the position sensors make the driving system expensive and unstable if the attached sensor malfunctions. Therefore, sensorless algorithms are widely researched nowadays, to reduce the cost and cope with sensor failure. This paper proposes a sensorless algorithm that can be applied to a wide range of speed. The proposed method features a robust operation at low-speed as well as high-speed ranges by employing a gain adjustment scheme and intermittent voltage pulse injection method. In the proposed scheme the position estimation gain is tuned by a closed loop manner to have stable operation in tough driving environment. The proposed algorithm is fully verified by various experiments done with a 1 kW outer rotor-type PMSM.

A Photovoltaic Power Management System using a Luminance-Controlled Oscillator for USN Applications

  • Jeong, Ji-Eun;Bae, Jun-Han;Lee, Jinwoong;Lee, Caroline Sunyong;Chun, Jung-Hoon;Kwon, Kee-Won
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.48-57
    • /
    • 2013
  • This paper presents a power management system of the dye-sensitized solar cell (DSSC) for ubiquitous sensor network (USN) applications. The charge pump with a luminance-controlled oscillator regulates the load impedance of the DSSC to track the maximum power point (MPP) under various light intensities. The low drop-out regulator with a hysteresis comparator supplies intermittent power pulses that are wide enough for USN to communicate with a host transponder even under dim light conditions. With MPP tracking, approximately 50% more power is harvested over a wide range of light intensity. The power management system fabricated using $0.13{\mu}m$ CMOS technology works with DSSC to provide power pulses of $36{\mu}A$. The duration of pulses is almost constant around $80{\mu}s$ (6.5 nJ/pulse), while the pulse spacing is inversely proportional to the light intensity.

Pulseless Disease: Report of Two Cases (무맥증 수술치험 2례)

  • 박응범
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.127-132
    • /
    • 1970
  • A patient was 29 year old house wife who was admitted to the Yonsei University Medical Center on 6 th of Nov., in 1970, with chief complaints of complete loss of bilateral visual acuity, generalized weakness, frequent palpitations, claudication of masseter muscles and intermittent fainting. These symptoms were developed 5 years prior to admission. Physical finding on admission revealed complete loss of bilateral visual acuity, absence of both radial and carotid pulse, but there was good femoral and popliteal pulse. She couldn't open her mouth as she desired and had weakness of mastication. Radiological findings of plane chest PA were not significant. Aortogram(Cineangiogram) showed non-visualization of both carotid and subclavian arteries. It showed only innominate and interal mammary artery preoperatively. The operative findings were as follows: There were complete obliterative changes in both common carotid and subclavian arteries, and periarteritis in the innominate artery. Tube Dacron Prosthesis Bypass with V-arm between innominate artery and both common carotid arteries was performed after thromboendarterectomy. Histopathological finding of the thromboend arterectomy specimen was compatible with pulseless disease, which showed marked fibrous thickening of intima and a diffuse inflammatory cell infiltration of the whole layers. Her postopererative course was uneventful. Follow up aortogram(Cineangiogram) was taken on 11th postoperative day, which revealed both common carotid arteries patent. Her preoperative Subjective symtoms disappeared remarkably, such as her visual acuity improved much, fainting and vertigo disappeared completely and she can go to bath room without difficulty and help. Another patient was 34 year old house wife who was admitted on August, 1964 with chief complaints of frequent fainting and progresive visual loss. She was operated only thromboendarterectomy of both common carotid arteries. Postoperative course was smooth and subjective symptoms were disappeared.

  • PDF

Intrahepatic portosystemic shunt with a second degree atrioventricular block fixed by transvenous coil embolization in a dog

  • Lee, Seung-Gon;Nam, So-Jeong;Kim, Hyun-Wook;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.4
    • /
    • pp.493-500
    • /
    • 2008
  • A 2-year-old female Pekingese dog was presented with primary complaints including exercise intolerance and neurological sign associated with hepatic encephalopathy. The major findings in clinical examination included an intermittent seizure, a slow heart rate with pulse deficit, leukocytosis and anemia in hemogram, elevated pre- and post-prandial serum bile acid and hepatic enzymes, hypoproteinemia, coagulopathy, ammonium urate crystaluria and bilirubinuria. Diagnostic tests revealed an intrahepatic portosystemic shunt complicated with a second degree atrioventricular block and QT prolongation. The case was successfully treated with a transvenous coil embolization. Clinical signs were gradually improved and cardiac bradyarrhythmia disappeared. This case is a rare case of intrahepatic portosystemic shunts complicated with a cardiac bradyarrhythmia in a small breed dog fixed by a transvenous coil embolization.

Lerich syndrome; 1 case (Lehich 증후군;치험1례)

  • Go, Yeong-Sang;Gu, Ja-Hong;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.26 no.10
    • /
    • pp.808-811
    • /
    • 1993
  • Leriche syndrome ia a common entity which causes ischemia of the lower extremities. Since the introduction of aortic resection and homograft replacement by Oudot in 1951, reconstructive procedures to restore distal blood flow by either endarterectomy or, later, with prosthetic graft have become standardized. Recently we experienced a case of Leriche syndrome. A 50 year-old male patient admitted with intermittent claudication, impotence, and symmetrical atrophy at lower extremities. Aortogram revealed complete obstruction at infrarenal abdominal aorta and Doppler sonogram revealed only minimal blood flow at left femoral artery.Successful surgical treatment was accomplished with endarterectomy at proximal left renal artery and a bypass from abdominal aorta at the level of both renal arteries to both external iliac arteries with bifurcated Gore-tex vascular graft. After bypass operation, we did palpate with arterial pulse at both popliteal artery.He was recovered without complication.

  • PDF

A Case of Urinary Tract Infection Treated with Gagamyookmijihwang-tang(Jia-Jian-Liu-Wei-De-Huang-Tang) in Stroke Patient (중풍환자의 급성요도염에 대하여 단독 한방처방 투여로 치료한 1례)

  • Han, Jin-An;Cho, Ki-Ho;Kim, Jung-Jin
    • The Journal of Internal Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.286-291
    • /
    • 2002
  • Urinary tract infection(UTI) is one of the common complications in stroke patients. As it has negative effect on the recovery of stroke, it should be cured out immediately. But antibiotics might cause some adverse reactions such as diarrhea, eruption, anorexia, nausea and vomiting. so there have been several reports about treating urinary tract infection with Traditional Korean Medication. We treated a 54-year-old male patient with cerebral hemorrhage, who had had neurogenic bladder after stroke and had been urinated by intermittent catheterization. About 10 days later, he could void by himself without catheter, but showing the symptoms of UTI; Voiding pain, hematuria and yellowish pus. The pus culture grew Staphylococcus spp., which was resistant to most of antibiotics except vancomycin and teicoplanin. Based on accompanying symptoms of intermittent dizziness, headache, insomnia, nocturnal sweating, weak pulse, red tongue and urinary problem, we differentiated him as the deficiency of Yin of the Kidney[腎陰虛] and treated with Gagamyookmijihwang-tang (Jia-Jian-Liu-Wei-De- Huang-Tang), which improved his urinary symptoms and other general conditions without any side effect. In next follow-up culture, there was no pathogen. We conclude that Traditional Korean Medicine based on differentiation is useful in the treatment of urinary tract infection.

  • PDF

Mouse Somatosensory Cortex Stimulation Using Pulse Modulated Transcranial Magnetic Stimulation (구형파 변조된 경두개 자기자극을 이용한 쥐의 감각피질 자극실험)

  • Sun, Sukkyu;Seo, Taeyoon;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.482-485
    • /
    • 2016
  • In this work, a transcranial magnetic stimulation(TMS) experiment on animals is performed to stimulate the brain cortex of the mouse using modulated signals. The proposed TMS system is composed of the inverter, transformer, capacitor, variable inductor, and stimulation coil to generate 1.5 mT magnetic field in the brain cortex of the mouse. The stimulation signal is modulated to square wave where the carrier frequency is swept from 85 to 91 kHz to investigate the stimulation effect. The experimental result shows that when the carrier frequency of the stimulation signal is lower than 89 kHz, the reaction of the mouse does not change while the stimulation signal which has the carrier frequency higher than 89 kHz results in decreasing the threshold of the stimulus for the pressure.