• Title/Summary/Keyword: Intermittent heating system

Search Result 15, Processing Time 0.017 seconds

Application of the Outdoor Air Temperature Prediction Control for Intermittent Heating Residences (간헐난방주택에 대한 외기온도 예측제어 적용 연구)

  • 태춘섭;조성환;이충구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.682-691
    • /
    • 2001
  • Most of radiant floor heating systems are operated in the intermittent heating mode in Korea. The application possibility of predictive suboptimal control for Koran residential house was investigated by computer simulation and experiment. For this study, TRNSYS program was used and an experimental facility consisting of tow rooms ($3\times4.4\times2.8 m$) identical in construction was built. The facility enabled simultaneous comparison of two different control method. And real multi residential hose was investigated. Results showed that outdoor air temperature prediction control was superior to the conventional control for radiant floor heating system operated in the intermittent heating mode. New control system resulted in good thermal environment and les energy consumption.

  • PDF

Strategy of Energy Saving and Thermal Environment Improvement for Intermittent Heating System in Apartment Buildings (공동주택 간헐난방시스템의 에너지 절감 및 열환경 개선방안 연구)

  • Ahn Byung-Cheon;Lee Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.88-93
    • /
    • 2005
  • In this study, the operational characteristics on heating performance and energy consumption for intermittent hot water heating system in apartment buildings were research by simulation. The effects of apartment inlet hot water temperature and operation time per day on energy consumption and indoor thermal environment are investigated. The strategy of energy saving and thermal environment improvement is suggested in comparison with the existing ones.

The Energy Analysis and Control Characteristics of a Hot Water Heating System for Apartment Houses (공동주택용 온수난방 시스템의 에너지해석 및 제어특성)

  • 장효환;안병천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.76-87
    • /
    • 1996
  • Energy analysis for the hot water heating control system of apartment house complex is accomplished by computer simulation. Mathematical model of a boiler, pipe network and a unit-house is developed. The effects of heating control methods on the heating performance and energy consumption of the system are investigated. The heating control methods considered in this study are a continuous heating control, and on-off heating control and an intermittent heating control methods. For each control method, the effects of an outdoor temperature, indoor temperature sensing position and the capacities of the boilers and circulating pumps on the heating performance and energy consumption are obtained and "the best" control method is recommended.commended.

  • PDF

Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing' (주거용건물의 바닥복사 난방방식에 대한 실태조사 연구)

  • Woo, Byung-Kwan;Lee, Sung;Kim, Sam-uel
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.

A Thermal Performance Analysis on the Operation Modes of Radiant Floor Heating System Using SERI-RES (SERI-RES를 이용한 Radiant Floor Heating System의 열 성능 분석)

  • Chun, Won-Gee;Jeon, Myung-Seok;Auh, P.Chung-Moo
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.29-33
    • /
    • 1991
  • The present paper deals with two types of heating methods widely used for the Radiant Floor heating systems in Korea. Of these, one method circulates hot water according to the predefined schedule ("intermittent heating") while the other runs the system with the aid of thermostats ("continuous heating"). The standard version of SERI-RES has been modified for the numerical simulation of the problem. Preliminary results show relatively large temperature swings in the case of intermittent heating with solar availability. On the other hand, the case of continuous heating would avoid such undesirable temperature fluctuations. These results are also verified by experimental evaluations.

  • PDF

An investigation on the heating energy consumption and operating condition in apartment houses (공동주택의 에너지소비량 및 난방운전 실태에 관한 조사연구)

  • 신용태
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.05a
    • /
    • pp.45-50
    • /
    • 1994
  • The energy consumption in apartment houses is investigated according to the heating systems, that is, district, central, and individual heating systems. And, operating conditions of intermittent heating are surveryed and analysed in the central heating systems. As a result, each annual energy consumption of district, central and individual heating system is 143.56 Mcal/m2year, 216.78 Mcal/m2year and 150.68 Mcal/m2year, Also, the heating is generlly started at 04:00 and 17:00 of each day, and the heating system is operated for 2~3 hours per each time.

  • PDF

Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature (지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토)

  • Bae, Sangmu;Jeon, Jae-Young;Kwon, Young Sik;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.4
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.

An experimental study on the heat transfer characteristics of a Ondol-heated space by varying pipe embedding depths and hot water supply conditions (보일러 운전조건 및 마감층 두께 변화에 따른 온돌난방공간의 열특성에 관한 실험연구)

  • 박병윤
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1991.09a
    • /
    • pp.41-47
    • /
    • 1991
  • This study reports the results of the transient temperature response of a floor heating panel according to variation of the hot water supply temperature and the pipe embedding depth. Also, this experiment compares the temperature responses of floor heating panels under the continuous and intermittent heating system. Furtthermore, this study presents some details of the thermal response of Ondol-heated buildings to varying loads and patterns of heat input. The analysis of the thermal performance fo Ondol heating system have been presented.

  • PDF

Energy Performance Analysis Program with Heating methods of Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방용 자동온도조절기의 난방방식에 따른 에너지성능 해석용 프로그램에 관한 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob;Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.381-386
    • /
    • 2008
  • In this study, the energy characteristic of automatic thermostatic valves according to each heating method in floor radiant heating system were researched by computer simulation. For the analysis of unsteady heat transfer phenomena in household, the method of using electrical equivalent R-C circuit is applied, and radiation heat transfer between panel, ceiling and walls in household is calculated by enclosure analysis method. The parametric study on heating method, valve's control method, outdoor air condition, supply heating water temperature, supply flow rate are performed to compare energy characteristic, respectively.

  • PDF

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF