• 제목/요약/키워드: Intermittent Pumping

검색결과 7건 처리시간 0.022초

Pulsed-laser-diode Intermittently Pumped 2-㎛ Acousto-optic Q-switched Tm:LuAG Laser

  • Wen, Ya;Jiang, Yan;Zheng, Hao;Zhang, Hongliang;Wang, Chao;Wu, Chunting;Jin, Guangyong
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.238-246
    • /
    • 2020
  • The heat distribution in crystals in a 2-㎛ acousto-optic Q-switched Tm:LuAG laser pumped by pulsed-laser-diode (pulsed-LD) intermittent-pumping technology was analyzed using COMSOL software. The thermal lensing effect of the Tm:LuAG crystal can be mitigated by pulsed-LD intermittent-pumping techniques. An experimental setup using this kind of approach achieved maximum output energy of 8.31 mJ, minimum pulse width of 101.9 ns, and highest peak power of 81.55 kW, reached at a Q-switched repetition rate of 200 Hz. It offers significant improvement of performance of the output laser beam, compared to pulsed-LD double-ended pumping technology at the same repetition rate.

아두이노를 활용한 반자동 간헐흐름식 수경재배 스마트팜 구현 (Implementation of Semi-Automatic Intermittent Flow Type Hydroponics Smart Farm using Arduino)

  • 장동환;김대희;이성진;문상호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.376-378
    • /
    • 2021
  • 세계기상기구가 발표한 2020년 글로벌 기후 보고서에 따르면, 2019년 지구의 평균 온도는 산업화 이전인 1850년에서 1900년사이에 측정된 온도보다 평균 1.1℃ 높게 측정되었다. 평균온도의 변화는 기온 상승이 식물 분포에 미치는 영향과 취약성 분석 논문의 따르면 평균온도의 상승시 식물의 분포되는 지역의 변화가 있다는 것을 알 수 있다. 본 논문에서는 이러한 환경 변화에 대응하기 위해, 아두이노와 센서를 사용하여 간헐흐름식 수경재배 스마트팜을 제작하고, PC와 어플리케이션을 통하여 제어하는 방법을 제안한다. 제작된 수경재배 스마트팜은 농장의 온습도, 양액의 ph농도, 조도, 수질의 정도를 파악하고, 양액의 양과 보충 필요 농도 확인, 조도의 따른 생장 LED 제어, 센서의 상태를 파악하여 농장의 전체적인 관리와, 식물의 모종 옮겨심기 이후의 적절한 환경에서 성장할 수 있도록 제어한다.

  • PDF

고압식 스크롤 압축기 스러스트 오일 그루브 최적 설계 (Optimal Design of Thrust Surface Oil Groove of a High Side Scroll Compressor)

  • 김현진;노영재
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.127-133
    • /
    • 2017
  • Performance analysis has been carried out on a high side scroll compressor that had a fixed scroll equipped with a circular oil groove on its thrust surface. Oil was supplied to the oil groove through an intermittent opening from a high pressure oil reservoir formed inside the orbiting scroll hub. Oil in the groove was then delivered to both suction and back pressure chambers by pressure differentials and viscous pumping action of the orbiting scroll base plate. Mathematical modeling of this oil groove system was incorporated into a main compressor performance simulation program for an optimum oil groove design. The study findings were as follows. Pressure in the oil groove can be controlled by changing its configuration and the oil passage area. With an enlarged oil passage, the pressure in the oil groove heightens due to an increased flow rate, but the pressure elevation in the back pressure chamber is small, resulting in reduced friction loss at the thrust surface between the two scrolls. On the other hand, by increasing the oil passage area, the oil content in the refrigerant flow increases. Considering all these factors, the energy efficiency ratio could be improved by about 3.6% under the ARI condition by an optimal oil groove design.

인공 하수처리수 주입과 양수 방식에 따른 인공 대수층의 해수침투평가 (Assessment on Saline Water Intrusion between Types of Injections of Artificial Reclaimed Water and Extractions in Artificial Aquifer)

  • 강정옥;이소정;김창균
    • 대한환경공학회지
    • /
    • 제28권6호
    • /
    • pp.603-612
    • /
    • 2006
  • 연안 대수층에 발생하는 해수침투를 효과적으로 방지하기 위한 대책으로서 인공 하수처리수의 대수층 함양수로의 가능성을 평가하고자 sand box를 이용한 실험실 규모의 연구를 수행하였다. 이를 위하여, 인공 대수층 내에서 다양한 양수 및 주입 조건에 따른 수리화학적 거동 특성을 평가하였다. 염수의 침투는 함양과 양수가 동시에 이루어질 때보다 양수가 없이 단지 함양만 이루어진 경우 더욱 저지되었다. 양수량과 함양량의 비가 $0.5{\sim}2$인 경우, 양수에 의하여 담수대로 침투하는 염수가 인공 수조 밖으로 배출됨과 동시에 함양에 의하여 함양관 주위로 형성된 수리화학적 방벽에 의하여 그 빈 공간은 함양수로 채워져 희석되어 해수침투가 후퇴되었다. 그러나 양수량이 함양량에 비하여 약 4배 이상인 경우 양수로 인한 빈 공간을 채울 만큼 함양량이 불충분해 염수는 담수대로 더욱 깊숙히 침투하였다. 양수량과 함얌량의 비가 $0.5{\sim}2$인 간헐적인 양수의 경우 S.M.I.값은 감소하였지만 그 비가 4이상인 경우 S.M.I.값은 $3{\sim}47%$로 오히려 증가하여 해수 침투가 진행됨을 나타내었다. 결론적으로 적절한 비율의 인공함양 혹은 간헐 양수방식을 채택할 경우 지하 대수층의 담수 자원을 안정적으로 이용하는 동시에 해수 침투를 효율적으로 방지할 수 있음을 확인하였다.

다수 개 디스크 PZT 를 이용한 밸브리스 압전펌프의 연동구동 파형에 관한 연구 (A study on the peristaltic waveform of valveless PZT pump using disk type multi PZTs)

  • 함영복;박중호;윤동현;김한석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1824-1827
    • /
    • 2005
  • For application to micro fluid control systems such as ${\mu}TAS$ (Micro Total Analysis Systems) and DDS (Drug Delivery Systems), it is very significant to handle precise and minute flow rates with low pressure pulsation. In this study, a novel valveless piezoelectric pump using peristaltic motion with three disk type PZT actuators is presented. The newly devised pump with an effective size of $70mm{\times}60mm{\times}55mm$ has three actuator layers connected in series from inlet to outlet. The PZT actuator has a maximum displacement of 240 ${\mu}m$ and a maximum force of 1.6 N. When the driving voltage for PZT actuators is sequentially applied with a certain phase shift, the pumping is performed by peristaltic motion of liquid volume. The working fluid is shut off without the driving voltage. Three methods for sequential driving are proposed and experimentally investigated. First and second methods utilize an intermittent sinusoidal waveform with phase shift of $90{\circ}\;and\;120^{\circ}$, respectively. Third method uses a rectangular waveform with phase shift of $90^{\circ}$. A controller with multi-phase shifter is designed and fabricated. Then, frequency and voltage-flow rate characteristics and load pressure-flow rate characteristics are experimentally investigated to verify the validity of the developed pump.

  • PDF

터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구 (Study on Thermal Performance of Energy Textile in Tunnel)

  • 이철호;박상우;손병후;최항석
    • 대한토목학회논문집
    • /
    • 제33권5호
    • /
    • pp.1907-1914
    • /
    • 2013
  • 터널 내부의 지열을 활용하여 지열 냉난방 시스템 가동에 필요한 열에너지를 얻을 수 있는 텍스타일 형태의 지중열교환기(에너지 텍스타일)를 충남 서천군 일대의 철도 폐터널 벽면에 시험 시공하였다. 현장에 설치된 에너지 텍스타일의 성능을 평가하기 위해 냉방 운영과 난방 운영에 대한 일일 냉난방 모사 시험을 수행하였다. 일일 냉난방 모사 시험을 진행하는 동안 터널 벽면에 설치된 지중 열교환기로 유입/유출되는 순환수의 온도, 순환 유량, 터널 벽면 내부 지반의 온도, 터널 내부의 온도를 지속적으로 측정하였다. 시험을 통해 현장에 설치된 에너지 텍스타일은 난방가동에서 에너지 텍스타일 유닛당 57.6~143.5 W의 열교환률을 보였고 냉방가동에서는 362.3~558.4 W의 열교환률을 보였다. 또한, 시험결과로부터 터널에 설치된 지중열교환기의 열교환 성능은 터널 내부 기온의 변화에 큰 영향을 받는 것으로 나타났다. 또한, 전산유체 수치해석을 통하여 터널 내부 기온 변화를 고려한 현장 시험을 모사하여 적용된 수치해석 모델을 검증하였다. 검증된 수치해석 모델을 이용하여 콘크리트 라이닝 내부의 유도 배수재 설치 유무에 따른 에너지 텍스타일의 열적 거동에 대한 매개변수 연구를 수행하였다.

윤환관개방법과 적정시설 연구 (Research on the Methods and Proper Provisions for Rotational Irrigation)

  • 유한열
    • 한국농공학회지
    • /
    • 제13권1호
    • /
    • pp.2191-2205
    • /
    • 1971
  • 본 실험은 공시품종 농림6호를 택하였다. 이앙일은 6월14일이었으며 착공일은 6월20일이었고 총 관개일수는 110일이었다. 식재밀도는 $21cm{\times}21cm$로서 각 시험구의 크기는 $9.9m^2$(3평)이며 평당 70주를 심었다. 시험포토양은 Loam으로 화하적인 성분은 표-3과 같다. 물은 상류에 있는 서호저수지에서 흘러나오는 것을 양수해서 사용하였으므로 서호의 수질과 같았다. 총 관개일수 110일중 54일에 걸쳐 분산하여 비가 내렸으므로 수도재배의 성적에는 비교적 큰 영향을 미친 것 같다. 수도의 생육기간중 소비수량을 조사하고저 삼투량측정기, 감수심측정기, 라이시미터를 설치하였으며 조사한 결과 삼투량은 평균 14mm/day로 나타났다. 이 실험을 통하여 용수량을 적절한 때에 알맞게 공급함으로써 증수의 효과를 기대하였고 또 용수량의 절약을 꾀하고져 적정한 관개방법을 얻고져 하였다. 실험결과를 요약하면 다음과 같다. 1. 윤환관개구의 수량은 상시담수한 관개구 보다 증수효과를 보았다. 즉 8일 관개구는 보통구의 14.4% 증수되었고 상시 담수관개구(1일관개구)에 비해서는 27%의 효과가 있었다. 그러나 이것은 금년과 같은 호 조건의 강우에 힘입은 것이 아닌가 생각된다. 2. 관개용수에 있어서는 보통구에 대해서 밑다짐 9cm구와 비닐무공구는 약 52%의 용수량절약을 이루었고 8일 관개구와의 비교에서는 약 44%의 용수절약을 얻었다. 상시 담수구는 작물생육에도 악영향을 미쳐서 성장률도 좋지 않았으며 물의 소비량도 많음을 보았다. 3. 보통구에 대한 소비수량을 조사하여 보면 가장 많은 기간이 수잉기, 출수기에 있었고 그 이후는 감소현상을 나타냈다. 4. 계속 관개구(비닐처리구)는 다른 시험구에 비하여 5일 앞서 출수하였다. 5. 윤환관개구는 상시관개구에 비하여 출수가 늦은 현상이 나타났다.年)보다 많었고 또 평균온도(平均溫度)가 다소(多少) 낮었기 때문에 유의성(有意性)은 인정(認定)할 수 없었다. (5) 비닐처리구(處理區)는 용수(用水)의 절약(節約)은 컸으나 기타(其他) 요소(要素)에 있어서는 유의성(有意性)을 인정(認定)하지 못하였다. (6) 관개용수량(灌漑用水量)에 있어서는 전관개일수(全灌漑日數) 102일중(日中) 강우일수(降雨日數) 54일(日)을 제(除)한 나머지 실지(實地)로 관개(灌漑)한 48일(日)에 있어서 밑다짐 9cm 구(區)와 비닐무공구(無孔區)가 243.3mm의 관개용수량(灌漑用水量)으로 족(足)하였으며 67%의 용수절약(用水節約)을 보았고 기타(其他)는 그림 15에서 보는 바와 같은 용수절약(用水節約)을 인정(認定)하였다. (7) 침투량(浸透量)은 $40{\sim}30mm/day$였든 것이 비닐지수벽(止水壁)을 설치(設置)한 구(區)에서는 10mm 정도(程度) 감소(減少)됨을 알 수 있다. (8) 생육상태(生育狀態)가 양호(良好)하며 일반(一般) 상시(常時) 담수구(水區)와 같은 병해(病害)나 도복(倒伏) 현상(現狀)은 발견(發見)되지 않았다. (8) 용배수조직(用排水組織)이 완비(完備)되고 각구(各區)마다 급수관(給水管)이 개별(個別)로 설치(設置)되어야 절수(節水)도 되고 답내(畓內)의 수온(水溫)도 상승(上昇)함을 알았다.rghum식물(植物)의 환경온도(環境溫度)를 달리 하였을 때 NEL가치(價値)는 각각(各各) 4.87MJ($30/25^{\circ}C$), 5.46MJ($25/20^{\circ}C$) 및 5.81MJ/kg($18/8^{\circ}C$)로 변(變)하여 고온(高溫)에서 net energy lactation 축적(蓄積)이 크게 감소(減少)되었다.다. 그러나 기온(氣溫)이 낮은 조건(條件)에서는 예취관리(刈取管理)

  • PDF