• 제목/요약/키워드: Intermittent Operation

검색결과 176건 처리시간 0.024초

Effect of intermittent operation modes on performance of reverse osmosis (RO) membrane in desalination and water treatment

  • Yang, Heungsik;Choi, Jihyeok;Choi, Yongjun;Lee, Sangho
    • Membrane and Water Treatment
    • /
    • 제13권1호
    • /
    • pp.39-49
    • /
    • 2022
  • Seawater desalination is doubtlessly a viable option to supply fresh drinking water. Nevertheless, RO (reverse osmosis) desalination plants in specific areas may be intermittently operated to match the imbalance between water demand and supply. Although a handful of works have been done on other membrane systems, few studies have attempted to mitigate fouling in intermittent RO systems. Accordingly, the objectives of this paper were to examine the effect of the intermittent operation on RO fouling; and to compare four intermittent operation modes including feed solution recirculation, membrane storage in the feed solution, deionized water (DI) recirculation, and membrane storage in DI water. Results showed that intermittent operation reduced RO fouling under several conditions. However, the extents of fouling mitigation were different depending on the feed conditions, foulant types, and membrane lay-up methods. When the feed solution was recirculated during the lay-up, the restoration of the flux was less significant than that by the feed solution feed-up. The use of deionized water during the lay-up was effective to restore flux, especially when the feed solution contains scale-forming salts (CaSO4) and/or colloidal silica.

지중온도회복을 고려한 지열 히트펌프 시스템의 운전방법 검토 (Study on the Operation Method of Ground Source Heat Pump System Considering Recovery of Ground Temperature)

  • 배상무;전재영;권영식;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.24-30
    • /
    • 2020
  • Ground source heat pump (GSHP) systems are actively introduced as cooling and heating conditioning systems of buildings due to annual stable performance and easily maintenance. However, ground temperature imbalance is occurred when the GSHP is used for a long period. Therefore, in this study, we proposed the operation method of the system that considered the recovery time of heat source temperature. The entering water temperature (EWT) and heat exchange rate (HER) were comparatively analyzed according to the continuous and intermittent operation. Furthermore, the underground thermal environment was evaluated by numerical analysis model. As the result, the intermittent operation was a maximum of 12.3% higher HER during the heating period than the continuous operation. In addition, the overall ground heat source temperature at the intermittent operation was higher than it at the continuous operation.

태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구 (Simulation of Drying Grain with Solar-Heated Air)

  • 금동혁;김용운
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.65-83
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well. 2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air. 3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying. 4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis. 5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time. 6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture. 7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation. 8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise. 11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss. 12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method. 13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated. Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year. 14. Required fan horsepower and energy for the intermittent fan operation were 3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation. 15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use. 16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.

  • PDF

태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구 (Simulation of Drying Grain with Solar-Heated Air)

  • 금동혁
    • Journal of Biosystems Engineering
    • /
    • 제4권2호
    • /
    • pp.64-64
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well.2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air.3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying.4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis.5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time.6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture.7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation.8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise.11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss.12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method.13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated.Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year.14. Required fan horsepower and energy for the intermittent fan operation were3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation.15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use.16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.

저수지의 수질 관리를 위한 간헐식 양수통형 인공 순환 장치의 설계 방법 개발 (Design Methods of Intermittent Deep Draw Aeration System for Reservoir Water Quality Management)

  • 서동일;송무석;황현동;이은형
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.445-452
    • /
    • 2004
  • Intermittent deep draw artificial circulation system is one of the most widely used destratification systems to control algal bloom in reservoirs in Korea. However, there have been neither theoretical background of design criteria nor operation guide line for efficient application of the system available for such systems. A design method was developed to calculate required compressor capacity and number of circulation units considering physical interactions between stratified water layers and plumes induced by the intermittent deep draw artificial circulation system. The program was tested with data observed in Yeoncho Lake. The results indicated that the developed method can applied in the fields successfully. Further validation processes would improve design and operation methods.

Preschool children medium-long distance stereoscopic vision testing

  • Weiqiang, Zhao;Xiaowang, Qiao;Singh, Sukh Mahendra
    • Advances in Traditional Medicine
    • /
    • 제4권2호
    • /
    • pp.120-123
    • /
    • 2004
  • To test preschool children's medium- long distance stereoscopic vision normal average value, and intermittent strabismus children,s medium-long distance stereoscopic vision acuteness is the goal of this study. The software of random stereoscopic vision and graph, which is developed by Hu-Chong etc has been used, to test 414 cases normal preschool children and 19 cases intermittent exotropia childrens medium-long distance (1-5 m) stereoscopic vision (before operation and after operation). The normal average value of preschool children's medium-long distance stereoscopic vision was achieved. Intermittent exotropia children's stereoscopic vision acuteness was declined with the increase of distance. This method can provide reference as screening abnormal stereoscopic vision during scientific research and clinical work.

컴퓨터 시뮬레이션을 이용한 간헐폭기 MBR시스템에서의 유기물 및 영양염류 처리 성능 평가 (Evaluation of Biological Organic and Nutrient Removal Performance in Intermittent MBR Systems by Computer Simulation)

  • 유호식;이승희
    • 유기물자원화
    • /
    • 제21권3호
    • /
    • pp.82-92
    • /
    • 2013
  • 생물학적 질소 및 인을 제거하기 위한 경제적인 공법인 간헐 폭기 MBR공법은 내부순환이 없고, 간헐반응조 폭기 시간 조절을 통해서 반응시간을 조절할 수 있는 장점이 있다. 본 연구에서는 신기술로 인증 받은 폭기에너지 절약 공법인 신 간헐폭기-MBR공법, 그리고 간헐반응조 폭기/비포기 주기가 1시간/1시간 및 4시간/4시간인 일반적인 간헐 폭기 MBR공법에 있어서의 처리성을 컴퓨터시뮬레이션을 통해서 평가하였다. 폭기 주기가 1시간/1시간인 간헐폭기 MBR공법의 경우, 폭기 시 최대 용존산소 농도가 0.23mg/L가 되어, 동시 질산화/탈질 반응이 수행되는 것으로 나타나 질소와 인 제거 효율은 각각 57.0%, 55.0%로 가장 높았다. 본 연구는 유입수질이 일정한 경우에 있어서의 시뮬레이션을 수행하였으며, 각 시스템에 있어서의 실 처리장 적용성을 파악하기 위해서는 유입수질 변동에 따른 처리성을 평가할 필요가 있는 것으로 나타났다.

간헐포기 소화 슬러지의 고분자 응집제에 의한 개량과 입도 분포 변화에 관한 연구 (A Study on the Conditioning with Polymer and the Particle Size Distribution of Intermittent Aerobic Digestion Sludge)

  • 김희준;김성홍;최재성
    • 한국환경보건학회지
    • /
    • 제30권3호
    • /
    • pp.253-258
    • /
    • 2004
  • Synthetic organic polyelectrolytes can be used to condition sludges to enhance their dewaterability. Intermittent aerobic digestion is an useful digestion technology and has many advantages like neutral pH, low installation cost and easiness to operation. The objectives of this study were to investigate the dewaterability of intemittent aerobic digestion sludge and to find the relationship between dewaterability and particle size distribution change under the conditioning of intermittent aerobic digestion sludge by cationic polyelectrolyte. Digested sludge from intermittent aerobic digestion was used and cationic polyacrylamide polymer was added as a conditioner. CST(capillary suction time), TTF(time-to-filtration) were tested as a dewaterability index and the number of particle distribution was analyzed using particle size analyzer. The results indicate that cationic polyelectrolytes is useful to enhance dewaterability of intermittent aerobic digestion sludge. Mean particle diameter was increased as polymer dosage increased and its value was reached up to 100 mm on the condition of optimal cationic polymer dosage. CST and TTF are well correlated with mean particle diameter when the weighting order is 1.7. By the optimal conditioning with cationic polymer, particles in the filtrate are also reduced significantly and this means that conditioning is helpful to main stream by reducing SS loading from return flow.

수치해석을 통한 에너지 파일의 장기 운용에 따른 지반의 온도변화 분석 (Analysis on Temperature Change of Ground by Long-term Performance of Energy Pile)

  • 김범준;윤찬영
    • 한국지반공학회논문집
    • /
    • 제35권10호
    • /
    • pp.5-15
    • /
    • 2019
  • 본 연구에서는 에너지 파일의 장기적인 운용이 지반의 온도변화에 미치는 영향을 확인하기 위해, 에너지 파일이 설치된 지반을 모사하고 유한요소해석을 수행하였다. 해석은 간헐적 냉방조건(8시간 운용, 16시간 정지)에서 에너지 파일 내부에 설치된 열순환 파이프의 외경에서부터 파일 표면까지의 이격거리를 변화시켜가면서 수행하였다. 해석결과, 에너지 파일의 간헐적 냉방운용 조건에서의 장기적인 열교환은 지반 내부의 열적 회복력을 감소시키고, 잔류열에너지를 유발하여 주변지반의 온도를 증가시키는 것으로 나타났다. 또한 주변지반의 온도는 에너지 파일에 가까워질수록 더 높은 온도를 갖는 것으로 나타나며, 열순환 파이프 외측 콘크리트 말뚝의 표면간의 거리가 줄어들수록 온도는 더욱 증가하는 것으로 나타났다.

Life cycle cost analysis and smart operation mode of ground source heat pump system

  • Yoon, Seok;Lee, Seung-Rae
    • Smart Structures and Systems
    • /
    • 제16권4호
    • /
    • pp.743-758
    • /
    • 2015
  • This paper presents an advanced life cycle cost (LCC) analysis of a ground source heat pump (GSHP) system and suggests a smart operation mode with a thermal performance test (TPT) and an energy pile system constructed on the site of the Incheon International Airport (IIA). First, an economic analysis of the GSHP system was conducted for the second passenger terminal of the IIA considering actual influencing factors such as government support and the residual value of the equipment. The analysis results showed that the economic efficiency of the GSHP system could be increased owing to several influential factors. Second, a multiple regression analysis was conducted using different independent variables in order to analyze the influence indices with regard to the LCC results. Every independent index, in this case the initial construction cost, lifespan of the equipment, discount rate and the amount of price inflation can affect the LCC results. Third, a GSHP system using an energy pile was installed on the site of the construction laboratory institute of the IIA. TPTs of W-shape and spiral-coil-type GHEs were conducted in continuous and intermittent operation modes, respectively, prior to system operation of the energy pile. A cooling GSHP system in the energy pile was operated in both the continuous and intermittent modes, and the LCC was calculated. Furthermore, the smart operation mode and LCC were analyzed considering the application of a thermal storage tank.