• 제목/요약/키워드: Intermediate treatment

검색결과 518건 처리시간 0.028초

고정도.고속 Groove Die Set (High-accuracy and High-speed Groove Die Set)

  • 김건회
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.7-15
    • /
    • 2008
  • Currently existing high-accuracy and high-speed die sets used in reciprocal press create scratches at the surface of guide posts, steel balls, and bushes due to vertical movement of balls with point-contacts between inner surface of bushes and guide posts. Consequently, accuracy of the die set and the life span of the metal mold are reduced. However, those scratches could reduce the pre-load of the steel ball. This research designed and developed a groove-type die set which improves life span of the die set by eliminating point-contacts of steel balls with guide posts. The guide post consisted of a steel-ball retainer, a steel-ball retainer stopper, a guide bush, a guide pin, a snap ring, and a spring. The steel-ball retainer has 72 holes with 8 columns of 9 holes in each column. The inner surface of the guide bush was grinded(surface roughness: $Ra\;\\;0.2{\mu}m$, accuracy: $0\;{\sim}\;-0.002mm$) after NC turning and heat treatment. Also, a line of small intermediate pocket was processed inside of the guide bush for lubrication and elimination of foreign materials. Guide grooves of steel balls were processed using a wire EDM(Electrical Discharge Machining) after heat treatment. With such a design of the guide post stated above, loads against steel balls could be dispersed greatly by the line contacts through the guide groove between the guide post and the guide bush, and the life span of the guide post could be expanded semi-permanently.

재생골재를 함유한 콘크리트의 열팽창계수 측정 (Measurement for Coefficient of Thermal Expansion of Concretes Made with Recycled Concrete Aggregates)

  • 양성철;이활웅;김남호
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.7-16
    • /
    • 2015
  • PURPOSES : This study was performed to determine a systematic approach for measuring the coefficient of thermal expansion (COTE) of concrete specimens. This approach includes the initial calibration of measurement equipment. Test variables include coarse aggregate types such as natural aggregate, job-site produced recycled concrete aggregate, and recycled aggregate processed from an intermediate waste treatment company. METHODS : First, two cylindrical SUS-304 specimens with a known COTE value of $17.3{\times}10^{-6}m/m/^{\circ}C$. were used as reference specimens for the calibration of each measurement system. The well-known AASHTO TP-60 COTE apparatus for concrete measurement was utilized in this study. Four different measurement apparatuses were used with each LVDT installed and a calibration value was determined using each measurement apparatus. RESULTS : In the initial experimental stage, calibration values for each measurement apparatus were assumed to be almost identical. However, using the SUS-304 samples as a reference, the calibration values for the four different measurement apparatuses were found to range from 3.49 to $8.86{\times}10^{-6}m/m/^{\circ}C$. Using different adjusted values for each measurement apparatuses, COTE values for the three different concrete specimens were obtained. The COTE value of concrete made with natural coarse aggregate was $9.91{\times}10^{-6}m/m/^{\circ}C$, that of job-site produced recycled coarse aggregate was $10.45{\times}10^{-6}m/m/^{\circ}C$, and that of recycled aggregate processed from the intermediate waste treatment company was $10.82{\times}10^{-6}m/m/^{\circ}C$. CONCLUSIONS : We observed that the COTE value of concrete made from recycled concrete aggregates (RCA) was higher than that of concrete made from natural coarse aggregate. This difference is due to the fact that the total volumetric mortar proportion in the RCA mix is higher than that in the concrete mix made with natural coarse aggregate.

근골격계 통증환자에서 반복 자기자극치료의 통증완화효과: 예비연구 (Short-Term Pain Relief by Repetitive Peripheral Magnetic Stimulation in Patients with Musculoskeletal Pain: A Pilot Study)

  • 박준현;곽현석;박우경;김민영;민경훈
    • Clinical Pain
    • /
    • 제19권1호
    • /
    • pp.16-22
    • /
    • 2020
  • Objective: Recent studies have shown that repetitive peripheral magnetic stimulation (rPMS) reduces pain in various conditions. This pilot study aimed to investigate the effects of rPMS depending on the pain characteristics. Method: Adult patients aged 19~85 years evaluated at our institution between September 1, 2017 and February 28, 2018 for subacute to chronic musculoskeletal pain equivalent to a numeric rating scale of 3 or higher for at least one month were enrolled. Pain scores as determined using a numeric rating scale at baseline and at the end of treatment were set as the primary outcome. Additionally, we classified the pain into nociceptive, intermediate, or neuropathic pain using the PainDETECT questionnaire and compared the responsiveness to rPMS according to the type of pain. Results: The average pain scores significantly decreased after the 2-week rPMS treatment in all enrolled subjects (p<0.001). There was no statistically significant difference in pain reduction between groups divided by PainDETECT questionnaire. Conclusion: This study suggests that rPMS could safely relieve various types of pain.

Effect of additional heat-treatment temperature on chemical, microstructural, mechanical, and electrical properties of commercial PAN-based carbon fibers

  • Cho, Dong-Hwan;Yoon, Sung-Bong;Cho, Chae-Wook;Park, Jong-Kyoo
    • Carbon letters
    • /
    • 제12권4호
    • /
    • pp.223-228
    • /
    • 2011
  • In this present work, the effect of additional heat-treatment (AHT) in the range from $1800^{\circ}C$ to $2400^{\circ}C$ on the chemical composition, morphology, microstructure, tensile properties, electrical resistivity, and thermal stability of commercial polyacrylonitrile (PAN)-based carbon fibers was explored by means of elemental analysis, electron microscopy, X-ray diffraction analysis, single fiber tensile testing, two-probe electrical resistivity testing, and thermogravimetric analysis (TGA). The characterization results were in agreement with each other. The results clearly demonstrated that AHTs up to $2400^{\circ}C$ played a significant role in further contributing not only to the enhancement of carbon content, fiber morphology, and tensile modulus, but also to the reduction of fiber diameter, inter-graphene layer distance, and electrical resistivity of "as-received" carbon fibers without AHT. The present study suggests that key properties of commercial PAN-based carbon fibers of an intermediate grade can be further improved by proprietarily adding heat-treatment without applying tension in a batch process.

Effect of Anti-Juvenile Hormone Analogue (AJH) Treatments on the Silk Filament Properties of the Silkworm, Bombyx mori L.

  • Moe;Bae, Do-Gyu;Sohn, Hae-Ryong;Seol, Kwang-Youl
    • 한국잠사곤충학회지
    • /
    • 제40권2호
    • /
    • pp.150-157
    • /
    • 1998
  • This study was carried out to define the effects of anti-juvenile hormone analogue(AJH) treatment at different silkworm larval stages on some silk filament properties. It was revealed that the treatments at the 1st and 2nd days of the 3rd instar as well as the 1st day of the 4th instar resulted to trimolters induction without lethal effect. The trimolters induced by treatment at the 1st day of the 4th instar showed the shortest larval duration and the lowest single cocoon weight, cocoon shell ratio, cocoon size, single filament length and denier of filament compared with those of the control, while the trimolters induced by the 3rd-instar treatment showed intermediate values. All treatments showed no significant differences from the aspect fo degumming ratio, elongation rate and crystallinity index of fibroin. However the silk filament obtained from the treatment at the 1st day of the 4th instar showed the highest tenacity which was revealed to be related to the better uniformity of filament by the means of microscopic photographing. FT-IR spectroscopy of the silk fibroin showed a sharp and strong peak at the position of 794.72 cm-1 in all AJH-treated samples regardless of trimolters induction, which was absent in control.

  • PDF

다양한 기판에 형성된 BDD 전극의 폐수처리 특성 (Performance of BDD Electrodes Prepared on Various Substrates for Wastewater Treatment)

  • 권종익;유미영;김서한;송풍근
    • 한국표면공학회지
    • /
    • 제52권2호
    • /
    • pp.53-57
    • /
    • 2019
  • Stability and activity of boron doped diamond (BDD) electrode are key factors for water treatment. In this study, BDD electrodes were prepared on various substrates such as Nb, Si, Ti, and $TiN_x/Ti$ by hot filament chemical vapor deposition (HFCVD) method. BDD/Ti film showed the delamination between BDD and Ti substrate due to the formation of TiC layer caused by diffusion of carbon. On the other hand, $BDD/TiN_x/Ti$ showed remarkably improved stability, compared to BDD/Ti. It was confirmed that $TiN_x$ intermediate layer act as barrier layer for diffusion of carbon. High potential window of 2.8 eV was maintained on the $BDD/TiN_x/Ti$ electrode and, better wastewater treatment capability and longer electrode working life than BDD/Nb, BDD/Si and BDD/Ti were obtained.

Diagnostic Accuracy of Dermoscopy for Scabies

  • Li, Feng-Zeng;Chen, Shuang
    • Parasites, Hosts and Diseases
    • /
    • 제58권6호
    • /
    • pp.669-674
    • /
    • 2020
  • The diagnostic accuracy of dermoscopy (DS) for scabies, a highly contagious parasitic disease, remains disputed. This study aimed to assess the diagnostic accuracy of DS in scabies, analyze the factors influencing DS, and explore its role in post-treatment evaluation. Patients with suspected scabies were randomly divided into 2 groups: 71 patients in the skin scraping (SS) group and 73 patients in the DS group. The diagnostic efficiencies of SS and DS in these groups were calculated. We also analyzed the influence of body part and investigator competence on the accuracy of DS. Then 16 body parts with typical signs of scabies were monitored by DS 2 and 4 day after sulfur ointment treatment. The sensitivity and specificity of DS were 98.3% and 88.5%, respectively. Hands, arms, and the abdomen had higher positivity rates than other body parts (P<0.001). The accuracy of dermatologists' interpretations of images negative for scabies in the intermediate- and high-level groups was higher than that in the low-level group (P<0.001). At follow-up, the mites were still visible on 43.8% to 62.5% of the skin lesions 2 and 4 day after sulfur ointment treatment. These results showed that DS could significantly increase the accuracy of diagnosing scabies owing to its high sensitivity and specificity. Therefore, it may be useful for monitoring clinical responses to anti-parasitic treatment.

Evaluation of dose received by workers while repairing a failed spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.442-448
    • /
    • 2022
  • Intermediate-level radioactive waste (ILW) is not subject to legal approval for cave disposal in Korea. To solve this problem, a spent resin treatment device that separates 14C-containing resin from zeolite/activated carbon and desorbs 14C through a microwave device has been developed. In this study, we evaluated the radiological safety of the operators performing repair work in the event of a failure in such a device treating 1 ton of spent resin mixture per day. Based on the safety evaluation results, it is possible to formulate a design plan that can ensure the safety of workers while developing a commercialized device. When each component of the resin treatment device can be repaired from the outside, the maximum and minimum allowable repair times are calculated as 263.2 h and 27.7 h for the 14C-detached resin storage tank and zeolite/activated carbon storage tank, respectively. For at least 6 h per quarter, the worker's annual dose limit remains within 50 mSv/year; further, over 5 years, it remained within 100 mSv. At least 6 h of repair time per quarter is considered, under conservative conditions, to verify the radiological safety of the worker during repair work within that time.

Evaluation of radiological safety according to accident scenarios for commercialization of spent resin mixture treatment device

  • Choi, Woo Nyun;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2606-2613
    • /
    • 2022
  • Spent resin often exceeds radiation limits for safe disposal, creating a need for commercial-scale treatment techniques to reduce resin radioactivity. In this study, the radiological safety of a commercialized spent resin treatment device with a treatment capacity of 1 ton/day was evaluated. The results confirm that the device is radiologically safe in the event of an accident. This device desorbs 14C from the spent resin, allowing disposal as low-level waste instead of intermediate-level waste. The device also reduces overall waste by recycling the extracted 14C. Potential accident scenarios were explored to enable dose assessments for both internal and external exposure while preventing further spillage of the device and processing the spilled resin. The scenarios involved the development of a surface fracture on the resin mixture separator and microwave systems, which were operated under pressure and temperature of 0-6 bar and 0-150 ℃, respectively. In the case of accidents with separator and microwave device, the maximum allowable working time of worker were derived, respectively, considering external and internal exposures. When wearing the respirator corresponding to APF 50, in the case of the microwave device accident scenario, the radiological safety was confirmed when the maximum worker worked within 132.1 h.

소규모 고도하수처리를 위한 변형 연속회분식공정에 관한 연구 (The Study of Modified Sequencing Batch Reactor Process for Small Advanced Wastewater Treatment)

  • 한운우;김규형
    • 한국지반환경공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.35-43
    • /
    • 2008
  • 본 연구는 소규모 하수고도처리시설에 대해 변형 연속회분식공정을 적용하여 그 효용성을 평가하였다. 변형 연속회분식공정은 단일 반응조 내에서 유기물질 및 질소, 인 등이 제거되며 유입수의 유량 및 수질특성에 의해 적합한 운전방식을 선택할 수 있다. 각 공정의 기능 향상을 위해 원수 유입조건의 제어, 간헐 폭기방식에 의한 무산소 및 호기조건의 적절한 분배 그리고 처리수와 잉여슬러지의 고액분리를 위한 처리수 배출장치의 적용으로 설계된 유량 및 수질에 비해 낮은 부하 조건임에도 1일 3Cycle 운전모드로써 안정적인 처리효율을 나타냈다. 평가결과 유기물질 제거효율은 BOD의 경우 평균 120.4mg/L에서 6.8mg/L로 94.4%, CODMn은 95.7mg/L에서 11.0mg/L로 88.5%의 처리효율을 나타냈다. T-N의 제거효율은 평균 32.2mg/L의 유입수 농도에 대해서 약 69.6%, T-P의 경우는 유입수 농도 4.65mg/L에 대해 73.6%의 처리효율을 나타냈다. 동절기 평균 T-N과 T- P의 처리효율은 58.8%, 68.5%로 약간 감소하였지만 안정적인 처리효율을 나타냈다. 1차 무산소 호기조건에서 BOD는 90%, T-N은 67% T-P는 46%정도로 제거되었으며 T-P는 2차 무산소 호기조건에서 약 70%정도 제거되었다. 따라서 유입수의 간헐유입과 무산소 호기조건의 적정한 분배에 의해 질산화, 탈질 및 인의 과잉섭취에 유기물이 적절히 이용된 것으로 평가되어 소규모 고도하수처리시설에 적합한 공정으로 판단된다.

  • PDF