• Title/Summary/Keyword: Interior air quality

검색결과 114건 처리시간 0.039초

A Decision Support Model for Intelligent Facility Management through the Digital Transformation

  • Lee, Junsoo;Kim, Kang Hyun;Cha, Seung Hyun;Koo, Choongwan
    • International conference on construction engineering and project management
    • /
    • The 8th International Conference on Construction Engineering and Project Management
    • /
    • pp.485-492
    • /
    • 2020
  • Information on the energy consumption of buildings that can be obtained through conventional methods is limited. Therefore, this study aims to develop a model that can support decision making about building facility management through digital transformation technologies. Through the IoT sensor, the building's energy data and indoor air quality data are collected, and the monitored data is visualized through the ELK Stack and produced as a dashboard. In addition, the target building is photographed with a 360-degree camera and maps using a tool to create a 360-degree tour. Using such digital transformation technologies, users of buildings can obtain various information in real time without visiting buildings directly. This can lead to changes in actions or actions for building management, supporting facility management decisions, and consequently reducing building energy consumption.

  • PDF

Interior Noise Characteristics of the Electric Trains in Gyeongchun Line (경춘선 전동열차의 실내 소음 특성)

  • Ann, Yong Chan;Lee, Jung Hyeok;Kim, Seock Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제38권7호
    • /
    • pp.817-822
    • /
    • 2014
  • Since the opening of the double-track railway for the Gyeongchun local electric train and the semi-high speed train ITX, floating population between Seoul and Chuncheon has rapidly increased. This is attributable to the competitiveness of the railway service in terms of punctuality and safety of operation, mass transportation and low fare. However, many passengers have expressed strong dissatisfaction and displeasure towards the interior noise and its high rate of increase, particularly in tunnel sections. In this study, the interior noise characteristics of Gyeongchun local electric train and ITX were analyzed and compared. Noise levels, frequency spectrum and sound quality indices were compared for the open land, tunnel and bridge. Finally, from the noise levels depending on the location in the vehicle compartment, the noise transmission path was determined and a basic strategy for reducing the interior noise was developed.

Correlation of Air Pollutants and Thermal Environment Factors in a Confined Pig House in Winter

  • Choi, Hong L.;Kim, Ki Y.;Kim, Hyunook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권4호
    • /
    • pp.574-579
    • /
    • 2005
  • Optimal management of indoor air quality in a confined pig house, especially in winter, is indispensable for preventing infectious respiratory disease to workers and animals. This study was performed to elucidate the correlation of aerial contaminants and climate factors in a confinement. It was observed that indoor air contaminants ion in the confinement was the highest at 2:00-5:00 pm in a day, followed by 8:00-11:00 pm and 8:00-11:00 am. This was attributed to the increase of pig activities in the afternoon. The concentration of total dust and total airborne bacteria was found to have a significant correlation with temperature and relative humidity (p<0.05). Correlation of total dust and total airborne bacteria, total dust and ammonia, and total dust and odor were shown statistically significant at 95% confidence level. In conclusion, temperature and total dust concentration correlated significantly with all the parameters except for hydrogen sulfide ($H_2S$). This could be explained by the fact the dryness of pig feces by increase of interior temperature and resuspension of feed deposited on the floor by the pig activity, resulted in high generation of dust which adsorbed and carried the airborne bacteria and odor compounds in a confined pig house. It was proved that the adsorptive capacity of dust with ammonia ($NH_3$) was higher than that with hydrogen sulfide ($H_2S$).

A Study on the Long-term Operating plan of Ventilation System of Apartment House in terms of Energy Performance (공동주택 강제 환기 시스템의 건물에너지 측면에서의 장기적 운영 방안에 관한 연구)

  • Kim, Seung-Chul;Yoon, Jong-Ho;Baek, Nam-Choon;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.115-123
    • /
    • 2011
  • Because buildings recently built have been highly insulated and highly airtight, it is impossible to emit toxic substances from interior finishing materials only by natural ventilation. Therefore, they cause indoor air pollution and it may threaten the user"s health such as atopic dermatitis, bronchial asthma and (allergic) rhinitis. Domestically, users spend indoors 80 percent of their time of a day. With the increased interest in indoor air quality, the introduction of forced ventilation system for new-built apartment buildings has been legislated. However, toxic substances from indoor are mostly below there commended standard approximately 23 months later. Thus, this study has assumed the status of the apartment buildings 23 months later through a simulation, regarded $CO_2$ as an exclusive indoor air pollution source. In the process of effectively eliminating the $CO_2$, this study has also been conducted on an operating plan that can provide superior performance from the energy side.

  • PDF

Failure Analysis of Air Vent Connected with Heat Supply Pipeline Under Manhole (맨홀에 설치된 지역난방 열공급관 에어벤트의 전단부 파손 원인 규명)

  • Cho, Jeongmin;Chae, Hobyung;Kim, Heesan;Kim, Jung-Gu;Kim, Woo Cheol;Jeong, Joon Cheol;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • 제19권4호
    • /
    • pp.196-202
    • /
    • 2020
  • The air vent connected to a heat supply pipeline in the district heating system has been used to eliminate the existing air in the pipe, which has a detrimental effect on corrosion durability and heat efficiency. Recently, the air vent installed under a manhole for 22 years was corroded and several pinholes were detected in the front-end of the air vent. To identify the cause of the failure, thickness reduction, corrosion products, and water quality were examined. The corrosion damage was significant at the outside of the front-end of the air vent where the insulator was covered. While a thin oxide layer was formed in the interior of the tube, the coarse and porous corrosion products consisting of magnetite and hematite were found externally. Water flowing into the thermal insulator was absorbed by the insulator following hydrolysis. The hydrolyzed insulator ejected the corrosion factors such as Cl-, SO42-, and NH4+. The findings suggest that the corrosion under insulation due to rain water is the main cause of the underlying failure in the air vent.

Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer (몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제64권4호
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

A study on the relationship between acoustic modes in tire-wheel guard space and high frequency road noise (타이어-휠가드 공간의 음장모드와 고주파성 로드노이즈의 상관성 연구)

  • Lee, Jong Hyun;Ku, Yo Cheon;Lee, Jin Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • 제35권4호
    • /
    • pp.288-294
    • /
    • 2016
  • The space between tire and wheel guard acts as a path for tire pattern noise transmission. In this study, acoustic phenomenon occurring in the tire-wheel guard space is investigated using acoustic mode analysis and visualization of the sound pressure distribution over the wheel guard surface. We introduced a cavity over the wheel guard surface to reduce the tire pattern noise, where the cavity acts as an acoustic damper. The interior noise was reduced by 2 dB(A), and the noise control measures treated in this study may provide an efficient method to improve interior sound quality without increasing cost and weight at the final stage of the vehicle development.

Analysis on TVOC Concentrations and Influence Factors of Newly-Built Apartments (신축 아파트의 총휘발성유기화합물 농도와 관련요인 분석)

  • Choi, Yoon-Jung;Kang, Mi-Ra;Lee, Hye-Min;An, Hye-Jung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 한국실내디자인학회 2006년도 춘계학술발표대회 논문집
    • /
    • pp.268-271
    • /
    • 2006
  • The purpose of this study was to identify the influence of living factors on TVOC(Total Volatile Organic Compounds) concentrations for newly-built apartments. The field measurements of TVOC concentrations were made totally 30 times(5 times per one subject house) in six apartment units in which residents recently moved. Those apartments authorized its business approval before May 2004, the Act of Indoor Air auality Management for multi-use facilities. The findings were as follows: The TVOC concentrations of the measured subject apartments ranged from about 1/10 of the recommended standard for multi-use facilities($400{\mu}g/m^3$) to up to 90 times as high as the standard. Since then, the Recommended Standard of Indoor Air Quality Management for newly-built apartment house was announced in December 2005. In accordance with this standard($2390{\mu}g/m^3$) it ranged from about 1/100 to up to 15 times as high as the standard. The subject house whose TVOC concentrations reduced below the recommendation standard in the shortest period had the largest amount of ventilation (all the windows were open for ventilation in the past three months) among ail measured houses. The reason of another house whose TVOC concentrations were much higher than the rest was fronted with new furniture in the room. It's recommended that they should open all the windows for at least three months for ventilation in newly-built houses, and it would be better to avoid remodeling than needs be.

  • PDF

A Study on Eco-friendly Indoor Space of Domestic Eco-certified (LEED)Building through the Cases Analysis & User's Satisfaction (LEED인증 건축물 분석을 통한 실내공간의 친환경성 개선방안에 관한 연구)

  • Na, Min-Hee;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • 제22권5호
    • /
    • pp.233-240
    • /
    • 2013
  • The building construction sector has been blamed as the main culprit of environmental contamination worldwide. So, there shall be some constructive alternatives in architectural engineering. As one of the alternatives, the LEED ("Leadership in Energy and Environmental Design") has been introduced since 1990s and has been well recognized in saving the resources and energy. "LEED" has also been introduced in Korea since 2002 but it has not put priority on the eco-friendliness of indoor space. In this study, the international and domestic green systems were analyzed and compared in order to restructure the checklist for indoor space. Using the restructured checklists, the questionnaire were sent to 180 people using 6 office buildings which passed the domestic "LEED" certification. LEED certification system put priority on the air quality and heating/cooling environment in its evaluation section and items. However, according to the results of the study, it was found that the people using the buildings were not satisfied enough with the air environment of buildings along with their other indoor environment items. This shows that even though the office buildings are designed according to the requirements of LEED, the buildings do not meet the occupier's needs. In addition, it showed that the evaluation items should be improved so that they are useful to enhance the satisfaction of the occupiers' needs. The paper could be useful in establishing standard for eco friendliness of indoor space of office buildings which pass the LEED certification as the basic data for increasing energy efficiency and working efficiency of occupiers of the buildings.

Noise Cancellation using Microphone Array in Digital Hearing Aids (디지털 보청기에서 마이크로폰 어레이를 이용한 잡음제거)

  • Bang, Dong-Hyeouck;Kil, Se-Kee;Kang, Hyun-Deok;Yoon, Gwang-Sub;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제58권4호
    • /
    • pp.857-866
    • /
    • 2009
  • In this paper, a noise cancellation-method using microphone array for digital hearing aids is proposed. The microphone array is located around the ear of a dummy. Speech sound is generated from the forward speaker positioned in the front of the dummy and noise sound is generated from the backward speaker. The speech and noise are mixed in the air space and entered into the microphones. VAD(voice activity detector) and ANC(adaptive noise cancellation) methods were used to eliminate noise in the sound of the microphones. 10 two-syllable words and 4 sentences were used for speech signals. Babble and car interior noise were used for noise signals. The performance of the proposed algorithm was evaluated by SNR(signal-to-noise ratio) and PESQ-MOS(perceptual evaluation of speech quality-mean opinion score). In babble noise condition, SNR was improved as much as $7.963{\pm}1.3620dB\;and\;3.968{\pm}0.6659dB$ for words and sentences respectively. In the case of car interior noise, SNR was improved as $10.512{\pm}2.0665dB\;and\;6.000{\pm}1.7642dB$ for words and sentences respectively. PESQ-MOS of the babble noise was improved as much as $0.1722{\pm}0.0861$ score for words and $0.083{\pm}0.0417$ score for sentences. And PESQ-MOS of the car interior noise was improved as $0.2661{\pm}0.0335$ score and $0.040{\pm}0.0201$ score for words and sentences respectively. It is verified that the proposed algorithm has a good performance in noise cancellation of microphone array for digital hearing aids.