• Title/Summary/Keyword: Interferometric synthetic aperture radiometer

Search Result 5, Processing Time 0.023 seconds

A Noise Re-radiation Calibration Technique in Interferometric Synthetic Aperture Radiometer for Sub-Y-type Array at Ka-Band

  • Seo Seungwon;Kim Sunghyun;Choi Junho;Park Hyuk;Lee Hojin;Kim Yonghoon;Kang Gumsil
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.577-580
    • /
    • 2004
  • To overcome with large size noise source distribution network design difficulty in interferometric radiometer system, especially for sub-Y-type array, a new on-board calibration technique using noise re-radiation is proposed in this paper. The suggested calibration technique is using noise re-radiation effect of center antenna after noise source injection from matched load. This approach is especially proper to sub-Y-type array interferometric synthetic aperture radiometer in mm-wave frequency band. Compared with noise injection network of a conventional synthetic aperture radiometer, the system mass, volume, and hardware complexity is reduced and cost-effective. Only one internal noise source, matched load, is used for injection using noise re-radiation technique a small set of sub-Y receiver channels is calibrated. Detailed calibration scenario is discussed and simulation results about noise re­radiation effect are presented.

  • PDF

High Spatial Resolution Imaging of the Contiguous Objects Using Sub-Y-Type Interferometric Synthetic Aperture Radiometer

  • Lee Ho-Jin;Park Hyuk;Kim Sung-Hyun;Choi Jun-Ho;Seo Seung-Won;Kim Yong-Hoon;Kang Gum-Sil
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.53-56
    • /
    • 2004
  • Recently the interferometric synthetic aperture radiometer with sub-Y-type antenna array was suggested to improve the spatial resolution than that of conventional Y-type with the same number of antenna elements. The sub-Y-type performance has been reported under a point source target. In this paper, the performance of sub-Y-type is evaluated under contiguous objects. The angular resolution of sub-Y-type with 52 antennas was compared with that of Y-type with the 40 antennas. The images of sub-Y -type and Y-type array were simulated under the contiguous objects. The sub-Y-type showed higher resolution than Y-type in the simulation and experiments. The sub-Y-type has high spatial resolution than Y-type in case of contiguous source as well as single point source.

  • PDF

Interferometric Synthetic Aperture Millimeter-wave Radiometer for the High Resolution Imaging

  • Kim, Yong-Hoon;Choi, Jung-Hee;Kang, Gum-Sil
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.122-126
    • /
    • 1999
  • The imaging characteristics of a 2-D interferometric synthetic aperture radiometer, such as an angular resolution, depend largely on the type of an antenna array. In this paper, different array configurations of antenna are studied and compared with each array types to get more high resolution image in spatial. T-, X- and Y- types of antenna array are considered and the performances of each type are analyzed considering spatial resolution. The simulation results of candidate antenna types are presented in this paper. In case of Y-type the coverage area of the visibility function is wide and the angular resolution is high more than the others. X-type array shows the good performance for side lobe level.

  • PDF

Experimental Results of Sub-Y-Type Array for High Angular Resolution Interferometric Radiometer at 37 GHz

  • Kang, Gum-Sil;Kim, Sung-Hyun;Choi, Jun-Ho;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.534-536
    • /
    • 2003
  • The Sub-Y-type array is proposed to decrease the number of antennas keeping same resolution or to use same number of antennas in order to have a narrow 3dB beamwidth. When the sub-Y-type array is des igned with 136 antennas for comparison with MIRAS, the reduction rate is theoretically 30 %. The proposed ideas are evaluated by experimental interferometric radiometer at 37 GHz.

  • PDF

SUB-Y-TYPE ANTENNA ARRAY CONFIGURATION FOR HIGH RESOLUTION INTERFEROMETRIC SYNTHETIC APERTURE RADIOMETER

  • Kang, Gum-Sil;Jiang, Jingshan;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.581-586
    • /
    • 2002
  • The development of 2-D radiometer is a new technical challenge for space borne remote sensing area. The Y-type antenna array has been proposed as a most efficient configuration because a large alias free FOV and a small-synthesized beam-width can be achieved compared to L-, T-type under the fixed antenna spacing. New configuration of antenna array, which is called sub-Y type configuration, is proposed to obtain a higher angular resolution than the case of Y-type array in the paper. The sub-Y type array is consisted of basic arrays, which are the Y-type array of four antenna elements. To analyze characteristics of the proposed configuration, the synthesized beam pattern is simulated through simulation. The secondary effect of the sub-Y-type is that the reconstructed image is suffered from the alias effect is appeared around the real target. The ghost targets in the reconstructed image can be reduced by the alias suppression algorithm introduced in this paper. In conclusion, the performance evaluation by use of array factor simulation shows more than 37.5% improvement in average for angular resolution and almost similar performance for temperature resolution.

  • PDF