• Title/Summary/Keyword: Interferometric Fringe Pattern

Search Result 8, Processing Time 0.019 seconds

Real-Time Correction of Movement Errors of Machine Axis by Twyman-Green Interferometry (광위상 간섭을 이용한 이송축의 운동오차 실시간 보상)

  • 이형석;김승우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3115-3123
    • /
    • 1993
  • This paper presents a real-time correction method of the movemont errors of a translatory precision machine axis. This method is a null-balances technique in which two plane mirrors are used to generate an interferometric fringe pattern utilizing the optical principles of TwymanGreen interferometry. One mirror is fixed on a reference frame, while the other is placed on the machine axis being supported by three piezoelectric actuators. From the fringe pattern, one translatory and two rotational error components of the machine axis are simultaneously detected by using CCD camera vision and image processing techniques. These errors are then independently suppressed by activating the peizoelectric actuators by real-time feedback control while the machine axis is moving. Experimental results demonstrate that a machine axis can be controlled with movement errors less than 10 nm in vertical straightness, 0.1 arcsec in pitch, and 0.06 arcsec in roll for 50mm travel by adopting the real-time correction method.

A Study on the Small Disturbance Measurement of Liquid Film Thickness by $Moir\acute{e}$ Fringe ($Moir\acute{e}$ Fringe에 의한 액막 두께 미소 변위 측정 연구)

  • Jeon, H.S.;Kim, K.H.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.29-35
    • /
    • 1997
  • Liquid film thickness is measured by $moir\acute{e}$ topography which monitored liquid surface. $Moir\acute{e}$ fringe measurement techniques share the inherent simplicity found in optical interferometric techniques have the advantage of use over a greater range of displacement. $Moir\acute{e}$ fringe are the geometric interference patterns observed when two dense line grating are superposed. Light transmitted through a fixed line grating is deviated by the liquid film surface, producing a distored image of the grating. The $moir\acute{e}$ fringe produced by projection of this optically distored grating onto a second stationary grating permit visualization of the liquid surface and measurement of the liquid film thickness. This study measured the small amplitude of liquid film thickness to the $moir\acute{e}$ fringe pattern produced when spherical metal was dropped glycerin put)1 And the measurement of liquid film thickness flowing down an inclined plate are required to calculate the liquid slope in a position.

  • PDF

Application of an Interferometric Biosensor Chip to Biomonitoring an Endocrine Disruptor

  • Kim, Byung-Woo;Lim, Sung-Hyuk
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.2
    • /
    • pp.118-126
    • /
    • 2004
  • Recombinant E.coli ACV 1003 (recA::lacZ) releasing ${\beta}$-galactosidase by a SOS regulon system, when exposed to DNA-damaging compounds, have been used to effectively monitor endocrine disruptors. Low enzyme activity of less than 10 units/mL, corresponding to a $\mu\textrm{g}$/L(ppb) range of an endocrine disruptor (tributyl tin, bisphenol A. etc.), can be rapidly determined, not by a conventional time-consuming and tedious enzyme assay, but by an alternative interferometric biosensor. Heavily boron-doped porous silicon for application as an interferometer, was fabricated by etching to form a Fabry-Perot fringe pattern, which caused a change in the refractive index of the medium including ${\beta}$-galactosidase. In order to enhance the immobilization of the porous silicon surface, a calyx crown derivative (ProLinker A) was applied, instead of a conventional biomolecular affinity method using biotin. This resulted in a denser linked formation. The change in the effective optical thickness versus ${\beta}$-galactosidase activity, showed a linear increase up to a concentration of 150 unit ${\beta}$-galactosidase/mL, unlike the sigmoidal increase pattern observed with the biotin.

Temperature Measurement Using Single-Mode Fiber Interferometric Sensor (단일모드 광섬유의 간섭계 센서를 이용한 온도측정)

  • 김덕수;이상호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.1-5
    • /
    • 1985
  • In this paper, temperature-induced optical phase shifts in single-mode fibers are studied both analytically and experimentally. Temperature sensor using single-mode fiber interferometer is designed and the temperature sensitivity of the sensor system is investigated. This fiber-optic temperature sensor which employs the Mach-Zehnder arrangement is a high sensitivity sensor of phase detection type. In this type, temperature changes are ob-served as a motion of an optical interference fringe pattern. In the measurements using interferometer, one of the important problems is to detect simultaneously the number and direction of fringe displacement resulting from physical perturbations (temperature, pressure, etc.). To realize this, the array detector using multi-mode fiber is designed. By this array detector the number and direction of fringe displacement is Ineasured very conveniently.

  • PDF

A Study on the Characteristics of Elastic Wave Propagation in Plates Using Pulse Laser Holographic Interferometry (펄스 레이저 홀로그래픽 간섭계를 이용한 평판의 탄성파 전파 특성에 관한 연구)

  • 이기백;나종문;김정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.106-112
    • /
    • 1996
  • In this paper, the propagation of elastic wave generated by loading impact to plates made of isotropic or anisotropic material was studied. And the influence of boundary conditions(free or clamped edge) upon the reflection of elastic wave of isotropic plate such as aluminum plate showed circular interferometric fringe pattern, whereas that of anisotropic plate such as epoxy composite laminates showed elliptical one. And the transverse displacement curves obtained from experiment and theory for both plates agreed well. Also, the waves reflected from the boundary edges showed much differences according to the boundary condition of edges.

  • PDF

A Study on the Characteristics of Elastic Wave Propagation in Plates Using Double Pulsed Laser Holographic Interferometry (이중펄스레이저 홀로그래픽 간섭법을 이용한 평판의 탄성파 전파특성에 관한 연구)

  • Lee, Ki-Baik;Na, Jong-Moon;Kim, Jeong-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3211-3223
    • /
    • 1996
  • In this paper, the propagation of elastic wave generated by loading impact to plates made of isotropic of anisotropic material was studied. And the influence of boundary conditions (free or clamped edge) upon the reflection of elastic wave was anlyzed. Also, double exposure holographic interferometer using ruby pulse laser was formed in order to investigate transient waves. Before the elasitc wave was reflected from the edges, the elastic wave of isotropic plate such as aluminum plate showed circular interferometric fringe pattern, whereas that of anisotropic plate such as epoxy composite laminates showed elliptical one. And the transverse displacement curves obtained from experiment and theory for both plates agreed well. Also, the waves reflected from the boundary edges showed much differences according to the boundary condition of edges.

Development of Bulge Testing System for Mechanical Properties Measurement of Thin Films : Elastic Modulus of Electrolytic Copper Film (박막의 기계적 물성 측정을 위한 벌지 시험 시스템 개발: 전해 동 박의 탄성 계수)

  • Kim, Dong-Iel;Huh, Yong-Hak;Kim, Dong-Jin;Kee, Chang-Doo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1807-1812
    • /
    • 2007
  • A bulge testing system was developed to measure mechanical properties of thin film materials. A bulge pressure test system for pressurizing the bulge window of the film and a micro out-of-plane ESPI(Electronic Speckle Pattern Interferometric) system for measuring deflection of the film were included in the testing system developed. For the out-of-plane ESPI system, whole field speckle fringe pattern, corresponding to the out-of-plane deflection of the bulged film, was 3-dimensionally visualized using 4-bucket phase shifting algorithm and least square phase unwrapping algorithm. The bulge pressure for loading and unloading was controlled at a constant rate. From the pressure-deflection curve measured by this testing system, ain-plane stress-strain curve could be determined. In this study, elastic modulus of an electrolytic copper film 18 ${\mu}m$ was determined. The modulus was calculated from determining the plain-strain biaxial elastic modulus at the respective unloading slopes of the stress-strain curve and for the Poisson's ratio of 0.34.

  • PDF

A NEW HARDWARE CORRELATOR IN KOREA: PERFORMANCE EVALUATION USING KVN OBSERVATIONS

  • Lee, Sang-Sung;Oh, Chung Sik;Roh, Duk-Gyoo;Oh, Se-Jin;Kim, Jongsoo;Yeom, Jae-Hwan;Kim, Hyo Ryoung;Jung, Dong-Gyu;Byun, Do-Young;Jung, Taehyun;Kawaguchi, Noriyuki;Shibata, Katsunori M.;Wajima, Kiyoaki
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.2
    • /
    • pp.125-137
    • /
    • 2015
  • We report results of the performance evaluation of a new hardware correlator in Korea, the Daejeon correlator, developed by the Korea Astronomy and Space Science Institute (KASI) and the National Astronomical Observatory of Japan (NAOJ). We conduct Very Long Baseline Interferometry (VLBI) observations at 22 GHz with the Korean VLBI Network (KVN) in Korea and the VLBI Exploration of Radio Astrometry (VERA) in Japan, and correlated the aquired data with the Daejeon correlator. For evaluating the performance of the new hardware correlator, we compare the correlation outputs from the Daejeon correlator for KVN observations with those from a software correlator, the Distributed FX (DiFX). We investigate the correlated flux densities and brightness distributions of extragalactic compact radio sources. The comparison of the two correlator outputs shows that they are consistent with each other within < 8%, which is comparable with the amplitude calibration uncertainties of KVN observations at 22 GHz. We also find that the 8% difference in flux density is caused mainly by (a) the difference in the way of fringe phase tracking between the DiFX software correlator and the Daejeon hardware correlator, and (b) an unusual pattern (a double-layer pattern) of the amplitude correlation output from the Daejeon correlator. The visibility amplitude loss by the double-layer pattern is as small as 3%. We conclude that the new hardware correlator produces reasonable correlation outputs for continuum observations, which are consistent with the outputs from the DiFX software correlator.