• Title/Summary/Keyword: Interference noise

Search Result 1,339, Processing Time 0.023 seconds

Design of Interference Type Noise Barrier Using the BEM (경계요소법을 이용한 간섭형 방음벽의 설계)

  • 이상권;이승영
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.11
    • /
    • pp.831-837
    • /
    • 2003
  • This paper investigates the insertion loss of nosie barrier with a interference device, The efficiency of the conventional interference-type noise barrier depends on specific frequency, Thus this study is performed to improve the efficiency of the nosie barrierin the range of broadband frequency. by changing the shape of interference device and adding the channel with various depths, The boundary element method (BEM) is used to predict the insertion loss of noise barrier. Two-dimensional boundary element model is created to simulate the performance of long barrier with a line source.

Design of Interference Type Noise Barrier Using The BEM (경계요소법을 이용한 간섭형 방음벽의 설계)

  • Lee, Seung-Young;Lee, Sang-Kwon;Cho, Sung-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.749-754
    • /
    • 2002
  • This paper investigates the insertion loss of nosie barrier with a interference device. The efficiency of the conventional interference-type noise barrier depends on specific frequency. Thus this study is performed to improve the efficiency of the nosie barrier in the range of broadband frequency, by changing the shape of interference device and adding the channel with various depths. The boundary element method (BEM) is used to predict the insertion loss of noise barrier. Two-dimensional boundary element model is created to simulate the performance of long barrier with a line source.

  • PDF

Error Performance Analysis of Digital Radio Signals in an Electromagnetic Interference (EMI) Environment of Impulsive Noise Plus Disturbance (임펄스 잡음과 방해파에 의한 전자파 장해(EMI) 환경하에서의 디지털 무선통신 신호의 오율해석)

  • Cho, Sung-Eon;Leem, Kill-Yong;Cho, Sung-Joon;Lee, Jin
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.6 no.3
    • /
    • pp.36-54
    • /
    • 1995
  • The error performance of digital radio signals (i.e., M-ary PSK signal, DQPSK signal, MSK signal, GMSK signal) interfered by impulsive noise and electromagnetic interference (EMI) is analyzed and discussed. In analysis at first, the error rate equations have been derived in an electromagnetic interference plus impulsive noise environment. And then, the error performance has been evaluated and shown in figures as a function of carrier-to-noise ratio, carrier-to-interference ratio, impu- lsive index, gaussian noise to impulsive noise power ratio, and interference index to measure the amount of error degradation in digital radio signals. From the obtained results we have known that in the presence of m-distributed tone interference plus inpulsive noise, the more significant the electromagnetic interference amplitude varies, the more significant performance degradation is produced. The listing the digital radio signals from the most degraded to the least is that DQPSK, GMSK, QPSK and MSK signal. In the constant amplitude tone interference plus impulsive noise environment, the effect of in- terference nearly disappears over about 20dB in CIR. The effect of constant tone interference on error rate performance is reduced more remarkably in the region from 10dB to 15dB in CIR. In both enviroments of m-distributed tone interference and constant amplitude tone interference, the more electromagnetic interference amplitude varies and CIR increases, the more error perfor- mance is improved. But it is found out that the performance can not be improved significantly even the electromagnetic interference becomes weak. This describes that the impulsive noise affects dominantly to the performance degradation.

  • PDF

The Acoustical Characteristics of an Interference-type Noise Barrier (간섭형 방음벽의 음향특성)

  • 이우섭;정성수;서상준;전오성
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.517-522
    • /
    • 2000
  • This study is concerned with the acoustic characteristics for recently developed interference-type noise barrier (T-shaped). To modify the previous shape more conveniently the T-shaped noise barrier with tuning partitions was examined in detail by varying the number and the hight of tuning partitions. The 2-D boundary element method(BEM) analysis were compared with the experimental results of 1/10 reduced scale model.

  • PDF

Outage Probability Analysis with Rayleigh Faded Cochannel Interference and Gaussian Noise

  • Lee, Ik-Beom;Han, Yong-Yearl
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.3
    • /
    • pp.402-407
    • /
    • 1998
  • In this paper, an outage probability in the presence of Rayligh faded cochannel interference and Gaussian noise for cellular mobile telephone system is described. Our result is a computational formula that can be applied with or without Gaussian noise in Rayleigh faded cochannel interferences. Without Gaussian noise, the situation degenerates to usual case of the cochannel interferences. The result can be applied also in the presence of Gaussian noise with or without cochannel interference.

  • PDF

Real-time 14N NQR-based sodium nitrite analysis in a noisy field

  • Mohammad Saleh Sharifi;Ho Seung Song;Hossein Afarideh;Mitra Ghergherehchi;Mehdi Simiari
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4570-4575
    • /
    • 2023
  • Noise and Radio-frequency interference or RFI causes a significant restriction on the Free induction Decay or FID signal detection of the Nuclear Quadrupole Resonance procedure. Therefore, using this method in non-isolated environments such as industry and ports requires extraordinary measures. For this purpose, noise reduction algorithms and increasing signal-to-noise-and-interference ratio or SNIR have been used. In this research, sodium nitrite has been used as a sample and algorithms have been tested in a non-isolated environment. The resonant frequencies for the 150 g of test sample were measured at 303 K at about 1 MHz and 3.4 MHz. The main novelty in this study was, (1) using two types of antennas in the receiver to improve adaptive noise and interference cancellation, (2) using a separate helical antenna in the transmitter to eliminate the duplexer, (3) estimating the noise before sending the pulse to calculate the weighting factors and reduce the noise by adaptive noise cancellation, (3) reject the interference by blanking algorithm, (4) pulse integration in the frequency domain to increase the SNR, and (5) increasing the detection speed by new pulse integration technique. By interference rejection and noise cancellation, the SNIR is improved to 9.24 dB at 1 MHz and to 7.28 dB at 3.4 MHz, and by pulse integration 44.8 dB FID signal amplification is achieved, and the FID signals are detected at 1.057 MHz and 3.402 MHz at room temperature.

Power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal

  • Cao, Xiaoling;Yan, Liangjun
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.251-261
    • /
    • 2018
  • With the urbanization in recent years, the power line interference noise in electromagnetic signal is increasing day by day, and has gradually become an unavoidable component of noises in magnetotelluric signal detection. Therefore, a kind of power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal is put forward in this paper. The method first uses wavelet decomposition to change single-channel signal into multi-channel signal, and then takes advantage of blind source separation principle of independent component analysis to eliminate power line interference noise. There is no need to choose the layer number of wavelet decomposition and the wavelet base of wavelet decomposition according to the observed signal. On the treatment effect, it is better than the previous power line interference removal method based on independent component analysis. Through the de-noising processing to actual magnetotelluric measuring data, it is shown that this method makes both the apparent resistivity curve near 50 Hz and the phase curve near 50 Hz become smoother and steadier than before processing, i.e., it effectively eliminates the power line interference noise.

Inter Pixel Interference Reduction using Interference Ratio Mask for Holographic Data Storage (홀로그래픽 정보 저장장치에서의 간섭 비율 마스크를 이용한 인접 픽셀 간섭의 개선을 위한 연구)

  • Lee, Jae-Seong;Lim, Sung-Yong;Kim, Nak-Yeong;Kim, Do-Hyung;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.42-46
    • /
    • 2011
  • Holographic Data Storage System (HDSS), one of the next generation data storage devices, is a 2-dimensional page oriented memory system using volume hologram. HDSS has many noise sources such as crosstalk, scattering and inter pixel interference, etc. The noise source is changing intensity of the light used for carrying the data signal in HDSS. The inter pixel interference results in decrease of Signal to Noise Ratio and increase of Bit Error Rate. In order to improve these problems, this paper proposes to compensate the inter pixel interference with simple interference mask.

A study on the performance test and acoustic design of interference type noise reduction device for railway noise (철도소음 저감을 위한 간섭형 방음장치 음향 설계 및 성능시험에 관한 연구)

  • Cho, Jun-Ho;Koh, Hyo-In
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.787-795
    • /
    • 2011
  • Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD), acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.

Noise reduction of noise barrier with noise reducer for high speed train by using scale down model test (축척모형 실험에 의한 고속전철 방음벽용 소음저감 장치)

  • 정성수;전병수;나희승;김준엽;양신추
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.647-652
    • /
    • 2001
  • A noise reduction of noise barrier for high speed train was measured by using scale down model test. A selected types of noise barriers were simple vertical barrier, interference type barrier with plate, interference type barrier with cylindrical pipes. On experiment, in order to make similar present test lane condition, reduced train model and multiple noise sources were considered. As a result. interference type noise barrier with cylindrical pipes is most effective than other barriers. A present height of noise barrier which is established in a test lane is not high enough for reducing patograph noise.

  • PDF