• Title/Summary/Keyword: Interface of rock and soil

Search Result 28, Processing Time 0.02 seconds

Prediction models of the shear modulus of normal or frozen soil-rock mixtures

  • Zhou, Zhong;Yang, Hao;Xing, Kai;Gao, Wenyuan
    • Geomechanics and Engineering
    • /
    • v.15 no.2
    • /
    • pp.783-791
    • /
    • 2018
  • In consideration of the mesoscopic structure of soil-rock mixtures in which the rock aggregates are wrapped by soil at normal temperatures, a two-layer embedded model of single-inclusion composite material was built to calculate the shear modulus of soil-rock mixtures. At a freezing temperature, an interface ice interlayer was placed between the soil and rock interface in the mesoscopic structure of the soil-rock mixtures. Considering that, a three-layer embedded model of double-inclusion composite materials and a multi-step multiphase micromechanics model were then built to calculate the shear modulus of the frozen soil-rock mixtures. Given the effect of pore structure of soil-rock mixtures at normal temperatures, its shear modulus was also calculated by using of the three-layer embedded model. Experimental comparison showed that compared with the two-layer embedded model, the effect predicted by the three-layer embedded model of the soil-rock mixtures was better. The shear modulus of the soil-rock mixtures gradually increased with the increase in rock regardless of temperature, and the increment rate of the shear modulus increased rapidly particularly when the rock content ranged from 50% to 70%. The shear modulus of the frozen soil-rock mixtures was nearly 3.7 times higher than that of the soil-rock mixtures at a normal temperature.

A study on the characteristics of landslide in heavy rainfall (a study by rock types) (폭우시 산사태 특성에 관한 연구 (암종에 따른 특성 연구))

  • 이수곤;박지호;선건규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.131-136
    • /
    • 2003
  • Landslide is a natural disaster frequently noticed In korea during monsoon season in flicting nationwise damages on human lives, properties, transportation networks, construction sites, etc. This study is about landslide characteristic in rainfall. This study selects seven sites that occured in 2001 and 2002. So elect areas divide and studied special quality by carcinoma by igneous rock, metamorphic rock, sedimentary rock. According to study finding, because igneous rock area is very thin into 1m interior and exterior soil layer, failures happened much rock and soil interface. There was place that depth of soil layer becomes about 2∼3m being area that receive serious weathering case of metamorphic rock. Therefore, at collapse much debriflow occurrence expect. Case that sedimentary rock area is broken through stratification looked. When see such results, it may become many helps to study characteristics of landslide occurrence area grasping collapse special quality by rock type.

  • PDF

A Study of Characteristic of Friction Angles between Sand and Artificial Rock Interface by Direct Shear Test (직접전단시험에 의한 모래와 인공암석 경계면의 마찰각 특성 연구)

  • Yang, Hong-Suk;Lee, Byok-Kyu;Jang, Seung-Jin;Lee, Su-Gon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.65-73
    • /
    • 2012
  • Soil-rock interface, mainly founded in Granite region of Korea, is known as one of the important factor of the slope failure at the rainfall due to smaller shear strength than soil itself. However, research of the effect on slope stability by soil-rock interfaces is insufficient. Therefore, a series of direct shear tests were performed in order to investigate the effect of soil-rock interface on slope stability. The method of tests is to get sand itself and sand-artificial rock interface shear strength from different grain size of sands and artificial rock samples. The results of tests show that the friction angle of interface depends primarily on particle size and surface roughness. Interface friction angle ratio ${\mu}(={\delta}/{\Phi})$ is in the range of 0.75 ~ 0.96, this results indicate that interface friction angle is smaller than sand itself.

The Behavior of the Cast-in-place Pile Socketed in Rock Considering Soil-Structure Interaction (지반-구조뭍간 상호작용을 고려한 암반에 근입된 현장타설말뚝의 거동)

  • 최진오;권오성;김명모
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.211-222
    • /
    • 2000
  • The design values of rock socketed pile related with properties of rock mass are not clearly established. However, the drilled shafts socketed in rock are widely used as the foundation of large scaled structure. In this study, the characteristics of behavior of rock socketed pile is researched, and the properties of interface between pile and rock considering soil-structure interaction are evaluated for numerical modeling of rock socketed pile based on the previous researches. Based on the properties of interface and rock mass, the behaviors of rock socketed piles are numerically modeled and compared with field measurement. To verify the numerical analysis, a micro pile socketed in rock is modeled and the results of numerical analysis are compared with field measurement. The numerical results show a good agreement with field measured data, especially in terms of load transfer characteristics.

  • PDF

The Behavior of the Cast-in-place Pile Socketed in Rock Considering Soil-Structure Interaction (지반-구조물간 상호작용을 고려한 암반에 근입된 현장타설말뚝의 거동)

  • 최진오;권오성;김명모
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.457-468
    • /
    • 2000
  • The design values of rock socketed pile related with properties of rock mass are not clearly established. However, the drilled shafts socketed in rock are widely used as the foundation of large scaled structure. In this study, the characteristics of behavior of rock socketed pile is researched, and the properties of interface between pile and rock considering soil-structure interaction are evaluated for numerical modeling of rock socketed pile based on the previous researches. Based on the properties of interface and rock mass, the behaviors of rock socketed piles are numerically modeled and compared with field measurement. To verify the numerical analysis, a micro pile socketed in rock is modeled and the results of numerical analysis are compared with field measurement. The numerical results show a good agreement with field measured data, especially in terms of load transfer characteristics.

  • PDF

A study on landslide charateristics by using the shear strength of the interface of rock and soil (암과 흙 경계면에서의 전단강도를 이용한 산사태 특성 연구)

  • Lee, Su-Gon;Sun, Gun-Kyu;Lee, Chun-Young;Kim, Jae-Heun;Lee, Chang-No
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.606-613
    • /
    • 2004
  • One of the major forces that causes landslide is the amount of underground water resulted from rainfall and shear strength. As a result of close study on the landslide area affected by typoon Rusa it is observed that many landslides took place at the interface of rock and soil. Based on this observation that shear strength at the interface played a great role in landslide of the hilly area, two shear strengths were measured on different places, one at the interface between rocks and soil and the other just on soil. The two values thus derived were compared and used to review the safety factor for the hilly areas already collapsed. Back analysis was also used to calculate the ground water table according to the different rock types at the time when degradation happened.

  • PDF

A Study on Friction Angle of Rock-Soil Contacts for Rock Type (암종에 따른 토사와 암반 경계면의 마찰각 변화 특성에 관한 연구)

  • Lee, Su-Gon;Lim, Chang-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.3
    • /
    • pp.9-14
    • /
    • 2002
  • It is common that the soil layer is few meters below the earth surface and there are rock masses below the soil layer in the view of geological characteristics in Korea. The boundary between rock and soil is clearly divided. When dealing with the stability of rock masses, as in the case of rock slopes or dam foundations, the majority of the collapses is not within the soil layer, but within the soil-rock boundary. Therefore, it is important to identify the shear strength characteristics between soil-rock contacts. It has been common practice to assume that the strength of the soil or shale represents the minimum strength present. However, it has been suggested by Patton(1968) that such an assumption may not be valid and that lower shear strengths might be obtained along the soil-rock interface than for either material alone. Then, in this thesis, introduce rock and residual soil shear strength tests and the specimen preparation and testing procedures are described in detail and also the testing results are presented and discussed.

DEM analyses of the mechanical behavior of soil and soil-rock mixture via the 3D direct shear test

  • Xu, Wen-Jie;Li, Cheng-Qing;Zhang, Hai-Yang
    • Geomechanics and Engineering
    • /
    • v.9 no.6
    • /
    • pp.815-827
    • /
    • 2015
  • The mechanical behavior of soil and soil-rock mixture is investigated via the discrete element method. A non-overlapping combination method of spheres is used to model convex polyhedron rock blocks of soil-rock mixture in the DEM simulations. The meso-mechanical parameters of soil and soil-rock interface in DEM simulations are obtained from the in-situ tests. Based on the Voronoi cell, a method representing volumtric strain of the sample at the particle scale is proposed. The numerical results indicate that the particle rotation, occlusion, dilatation and self-organizing force chains are a remarkable phenomena of the localization band for the soil and soil-rock mixture samples. The localization band in a soil-rock mixture is wider than that in the soil sample. The current research shows that the 3D discrete element method can effectively simulate the mechanical behavior of soil and soil-rock mixture.

Tests of the interface between structures and filling soil of mountain area airport

  • Wu, Xueyun;Yang, Jun
    • Geomechanics and Engineering
    • /
    • v.12 no.3
    • /
    • pp.399-415
    • /
    • 2017
  • A series of direct shear tests were conducted to investigate the frictional properties of the interface between structures and the filling soil of Chongqing airport fourth stage expansion project. Two types of structures are investigated, one is low carbon steel and the other is the bedrock sampled from the site. The influence of soil water content, surface roughness and material types of structure were analyzed. The tests show that the interface friction and shear displacement curve has no softening stage and the curve shape is close to the Clough-Duncan hyperbola, while the soil is mainly shear contraction during testing. The interface frictional resistance and normal stress curve meets the Mohr-Coulomb criterion and the derived friction angle and frictional resistance of interface increase as surface roughness increases but is always lower than the internal friction angle and shear strength of soil respectively. When surface roughness is much larger than soil grain size, soil-structure interface is nearly shear surface in soil. In addition to the geometry of structural surface, the material types of structure also affects the performance of soil-structure interface. The wet interface frictional resistance will become lower than the natural one under specific conditions.

FE Analysis of Rock-Socketed Drilled Shafts Using Load Transfer Method (유한요소해석을 통한 암반에 근입된 현장타설말뚝의 하중전이거동 분석)

  • Seol, Hoon-Il;Jeong, Sang-Seom;Kim, Young-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.12
    • /
    • pp.33-40
    • /
    • 2008
  • The load distribution and deformation of rock-socketed drilled shafts subjected to axial loads are evaluated by a load-transfer method. The emphasis is on quantifying the effect of coupled soil resistance in rock-socketed drilled shafts using the 2D elasto-plastic finite element analysis. Slippage and shear load transfer behavior at the pile-soil interface are investigated by using a user-subroutine interface model (FRlC). It is shown that the coupled soil resistance provides the influence of pile toe settlement as the shaft resistance is increased to an ultimate limit state. The results show that the coupling effect is closely related to the value of pile diameter over rock mass modulus (D/$E_{mass}$) and the ratio of total shaft resistance against total applied load ($R_s$/Q). Through comparisons with field case studies, the 2D numerical analysis reseanably presented load transfer of pile and coupling effect due to the transfer of shaft shear loading, and thus represents a significant improvement in the prediction of load deflections of drilled shafts.