• 제목/요약/키워드: Interdisciplinary

Search Result 3,522, Processing Time 0.032 seconds

Improve distance of Passive RFID system for 900MHz Using SAW device (SAW device를 이용한 900MHz 대역 수동형 RFID system의 인식거리 향상 연구)

  • Park, Joo-Yong;Kim, Jae-Kwon;Kim, Kyung-Hwan;Yeo, Joon-Ho;Burm, Jin-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.975-976
    • /
    • 2006
  • The passive type RFID (Radio Frequency Identification) System using Surface Acoustic Wave (SAW) tag at 900 MHz in the range of more than 1 m was fabricated. To improve interrogation range of the system propose a method to increase isolation between transmitter and receiver. This method using a direct conversion architecture achieves a leakage rejection of 10 dB increased compared with conventional system. Measured interrogation range is more than 1 m.

  • PDF

Surface Acoustic Waves Sensors for Wireless Measurement of Temperature (Surface Acoustic Wave를 이용한 무선 온도 센서 설계 및 구현)

  • Kim, Jaek-Won;Park, Joo-Yong;Kim, Kyung-Hwan;Yeo, Joon-Ho;Burm, Jin-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.469-470
    • /
    • 2006
  • Surface Acoustic Wave(SAW) devices can be used to as wireless sensor elements, called SAW transponders, for measuring shysical quantities such as temperature that do not need any power supply and may be accessed wirelessly. SAW devices were fabricated on Y-Z $LiNbO_3$ piezoelectric substrate with a good temperature coefficient property. The signal response of SAW sensor on the temperature change were compared. To measure the change of SAW velocity. Temperature changed form $20^{\circ}C$ to $400^{\circ}C$ was linearly changed, the SAW sensor is application to the temperature sensor.

  • PDF

PDMS Nanoslits without Roof Collapse

  • Lee, Jin-Yong;Yun, Young-Keu;Kim, Yoo-Ri;Jo, Kyu-Bong
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.8
    • /
    • pp.1793-1797
    • /
    • 2009
  • Soft lithography of polydimethyl-siloxane (PDMS), an elastomeric polymer, has enabled rapid and inexpensive fabrications of microfluidic devices for various biochemical and bioanalytical applications. However, fabrications of nanostructured PDMS components such as nanoslits remain extremely challenging because of deformation of PDMS material. One of the well-known issues is the unwanted contact between the surfaces of PDMS roof and bottom substrate, called ‘roof collapse’. Here we have developed a novel approach for the facile stabilization of PDMS nanoslits in the low height (130 nm)/width (100 $\mu$m) ratio without roof-collapse. Within 130 nm high nanoslits, we demonstrate the confinement of single DNA molecules. We believe that this approach will serve as a key to utilize PDMS as nanoslits for integrated microfluidic devices.

A SOD-Based Amperometric Biosensor for Superoxide Ion

  • Tian, Yang;Okajima, Takeyoshi;Kitamura, Fusao;Ohsaka, Takeo
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.4
    • /
    • pp.212-215
    • /
    • 2002
  • A superoxide dismutase (SOD)-based superoxide ion $(O_2^-)$ sensor was fabricated by immobilizing SOD on a self-assembled monolayer (SAM) of 3-mercaptopropionic acid (MPA) which was prepared on a gold electrode. The SAM of MPA was found to function as an effective promoter for the electrode reaction of SOD. The amperometric response to $(O_2^-)$ was monitored at 300mV and -100mV vs. Ag/ Agel in 5mM phosphate buffer solution containing $KO_2$. The sensor was proved to have a high sensitivity, selectivity and short response time (<5 s) and negligible interference.

An Intrusion Detection Method using the PrefixSpan Algorithm (PrefixSpan 알고리즘을 이용한 침입 탐지 방법)

  • Park, Jae-Chul;Lee, Seung-Yong;Kim, Min-Soo;Noh, Bong-Nam
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2003.05c
    • /
    • pp.2125-2128
    • /
    • 2003
  • 알려진 공격 방법에 대해서는 다양한 방법으로 공격을 탐지하여 적절한 대응을 할 수 있는 반면 알려지지 않은 방법에 의한 공격은 침입탐지 시스템에서 공격 자체를 인식하지 못하므로 적절한 대응을 할 수 없게 된다. 따라서 비정상행위에 대한 탐지를 위해 데이터마이닝 기술을 이용하여 새로운 유형의 공격을 추출하고자 하였다. 특히 대용량의 데이터에 공통적으로 나타나는 순차적인 패턴을 찾는 순차분석 기법 중 PrefixSpan알고리즘을 적용하여 비정상 행위 공격을 탐지할 수 있는 방법을 제시하였다.

  • PDF

Particle Image Velocimetry Measurement of Unsteady Turbulent Flow around Regularly Arranged High-Rise Building Models

  • Sato, T.;Hagishima, A.;Ikegaya, N.;Tanimoto, J.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.2
    • /
    • pp.105-113
    • /
    • 2013
  • Recent studies proved turbulent flow properties in high-rise building models differ from those in low-rise building models by comparing turbulent statistics. Although it is important to understand the flow characteristics within and above high-rise building models in the study of urban environment, it is still unknown and under investigation. For this reason, we performed wind tunnel experiment using Particle Image Velocimetry (PIV) to investigate and identify the turbulent flow properties and characteristic flow patterns in high-rise building models. In particular, we focus on instantaneous flow field near the canopy and extracted flow field when homogeneous flow field were observed. As a result, six characteristic flow patterns were identified and the relationship between these flow patterns and turbulent organized structure were shown.

The Study of Shop Floor Control System Under CIM Environment (CIM 환경에서의 현장관리시스템)

  • 남호기
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.21 no.46
    • /
    • pp.197-206
    • /
    • 1998
  • In recent years there has been a tremendous upsurge of interest in Shop Floor Control System (SFCS) design and analysis. We reviewed current computer-aided shop floor control system. It is concluded that current methodologies support, in a very restricted sense, these planning, scheduling, and monitoring activities and that enhanced performance can be achieved via an integrated approach. In this paper we present an interdisciplinary approach to the development and installing of sophisticated shop floor control systems. Interdisciplinary design will form the basis of designing SFCS in new knowledge intensive era. Interdisciplinary design means more than just applying knowledge from other domains, such as psychology and organization science to design of SFCS. The interdisciplinary approach is verified by an illustrative case study.

  • PDF

Lyotropic Chromonic Liquid Crystals in Aligned Films for Applications as Polarizing Coatings

  • Schneider, Tod;Golovin, Andrii;Lee, Jong-Chan;Lavrentovich, Oleg D.
    • Journal of Information Display
    • /
    • v.5 no.2
    • /
    • pp.27-38
    • /
    • 2004
  • We describe dried oriented films with anisotropic structural and optical properties prepared from the aqueous solutions of plank-like molecules, the so-called Lyotropic Chromonic Liquid Crystals (LCLCs). The dried LCLC films may be used as optical elements, such as polarizers, compensators, color filters, or retardation plates in the UV, visible, or infrared parts of spectrums. The optical quality of the films is determined by the uniformity of the molecular alignment, which often distorted by periodic variations of the director field. We describe different ways to improve the alignment properties of the films by using additives. We present compositions capable of polarizing effects in visible and UV parts of spectrum.

A Review on Impedance Cardiography and Its Oriental Medical Application (한의학적 활용을 위한 임피던스 심장기록법의 연구동향)

  • Ko, Young-Il;Lee, Hyon-Soo;Park, Young-Jae;Park, Young-Bae
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.10 no.2
    • /
    • pp.67-78
    • /
    • 2006
  • Objectives : To review the method, validity and reliability of Impedance Cardiography and to study its oriental medical application. Method : The papers reviewed in this study were searched through internet search engines such as Springer, Science Direct, and China National Knowledge Infrastructure. Conclusion : In this study, the methodological limitations, validity and reliability of impedance cardiography were examined. Impedance Cardiography is recognized as a highly accurate non-invasive tool to assess hemodynamic parameters. The ability of impedance cardiography to assess hemodynamic parameters in non-invasive way is very suitable for researches on the effect of oriental medical therapeutics or the validation of oriental medical diagnostic.

  • PDF