• Title/Summary/Keyword: Interconnection capacity

Search Result 59, Processing Time 0.041 seconds

Evaluation of Interconnection Capacity of SCOGNs to the power Distribution Systems from the Viewpoint of Voltage Regulation (전압조정 측면에서 본 소형 열병합발전 배전계통 도입량 평가)

  • 최준호;김재철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1096-1102
    • /
    • 1999
  • This paper discusses the evaluation of interconnection capacity of small cogeneration(SCOGN) systems to the power distribution systems from the viewpoint of voltage regulation. Power utilities are required to keep the customers' voltage profile over a feeder close to the rated value under all load conditions. However, it is expected that the interconnection of SCOGNs to the power distribution systems impacts on the existing voltage regulation method and customers' voltage variations. Therefore, SCOGNs should be integrated to the automated power distribution systems to prevent interconnection problems and supply high quality electricity to the customers. For these reasons, we should proceed with the evaluation of interconnection capacity of SCOGNs to the power distribution systems. However, it is generally impossible to perform actual testing on the power distribution systems, and standardized methodologies and guidelines are not developed to evaluate it. The criterion indexes for voltage regulation and variations are presented in order to evaluate the interconnection capacity of SCOGNs to the power distribution systems. In addition, the evaluation methodology of interconnection capacity of SCOGNs for power distribution systems is presented. It is expected that the resulted of this paper are useful for power system planners to determine the interconnection capacity of SCOGNs and dispersed storage and generation (DSG) systems to the power distribution systems.

  • PDF

The Study for Allowable Capacity of New Distributed Generation for Composite Distribution System Interconnected Distributed Generation (분산전원이 연계된 복합배전개통에 신규분산전원연계시 신규분산전원 도입량에 관한 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Choi, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.277-279
    • /
    • 2002
  • Recently, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern for DG(distributed generation) is growing. Present, allowable interconnection capacity of DG for composite distributed generation is studied. In this paper, it is studied that the new interconnection capacity of DG for composite distribution system interconnected DG. We study new allowable interconnection capacity by power factor and placement. We study SERV(sending end reference voltage) variation and allowable interconnection capacity interconnected new DG.

  • PDF

Impacts on short-circuit capacity by interconnection of new energy source generation into the distribution system (신 에너지전원설비의 배전계통 연계에 의한 단락용량 검토)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.476-479
    • /
    • 2001
  • Interconnection of new energy sources, such as photovoltaic generation, wind power generation, etc., into the electric power distribution system may result in the increasing short-circuit capacity when a short circuit fault occurs. The short-circuit capacity becomes over the interrupting ratings of circuit breakers, and then they fails to operate in the proper way they prevent fault currents from flowing into the distribution facilities and thus causing them serious damages. This study deals with impacts on the respective short-circuit capacity of both low voltage and extra high voltage distribution systems at which new energy sources are installed. In order to obtain more accurate and all-case values very close to reality in the complicated distribution system, computer simulation tools should be required. In this paper, however, its focus is placed on examining the varying trend of short-circuit capacity, which may happen owing to new energy source interconnection, as a previewing step for exhaustive simulation studies.

  • PDF

A Study on Settlements in Internet Interconnection under Internet Congestion (네트워크 혼잡효과를 고려한 인터넷망간 상호정산 방안 연구)

  • Jung, Choong-Young
    • Journal of Information Technology Applications and Management
    • /
    • v.14 no.2
    • /
    • pp.97-115
    • /
    • 2007
  • The present paper investigates the technological and conceptional characteristics of peering and transit in internet interconnection. Especially, the market with two ISP competing for customers is modeled and the outcome with peering is compared with transit. This paper also analyze the congestion effects on retail price and network capacity. When there is congestion effects occurring from network sharing, the retail price is increased and the fixed fee is decreased with the degree of congestion. Finally, the optimal access charge assuring the socially optimal retail price and network capacity is derived.

  • PDF

Interconnection Capacity Evaluation of Distributed Resources at the Distribution Networks in View of Distribution Protection Coordination (배전계통의 보호협조측면에서 본 분산전원 연계용량 검토)

  • Choi, Joon-Ho;Ro, Kyoung-Soo;Park, Sung-Jun;Song, Kyung-Bin;Yun, Sang-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.107-116
    • /
    • 2007
  • The introduction of new renewable energy is going on increase with the second plan of the Korean Government "Technology Development, Utilization and Popularization of New Renewable Energy". In general, it is connected to the power system due to the nature of it's source characteristics but it's interconnection operation impacts on the power system planning and operation. The operation schemes of the existing power distribution system are based on the unidirectional power flow, but unidirectional power flow changes to bidirectional power flow due to the interconnection operation of new renewable energy. It degrade the existing protection coordination system and power quality of the power distribution system. Thus, the technical evaluation process of the interconnection of new renewable energy are necessary. In this paper, the characteristics of the existing automatic recloser and sectionalizer are reviewed and interconnection capacity evaluation method of the DR(distributed resources) in the existing automatic recloser-sectionalizer protective coordination system are proposed.

A Study on the Assessment of Operational Capacity Limit of Wind Turbine for the Frequency Stability of Jeiu Island System (제주계통 단독운전 시 주파수 안정도 유지를 위한 풍력발전 운전용량 산정 방법에 관한 연구)

  • Hwang, Kyo-Ik;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.233-239
    • /
    • 2007
  • As the Kyoto Protocol, which aims at reducing greenhouse gases in accordance to the UNFCCC, came into force, research on environment friendly energy resources has been a matter of concern worldwide. As a general power generation system, among renewable energy resources, that is interconnected and operated with power system, the wind turbine is emerging as an effective alternative. Since power capacity of the wind turbine has been steadily increasing and its relative importance is also increasing in total facility capacity, we cannot ignore its effect. Because controlling generation output in the wind turbine is not as easy as in the synchronous machine due to its facility characteristics and it generates irregular output fluctuations when interconnected with power system, system interconnection was difficult. But the effect of large capacity wind turbine on isolated power system like Jeju island is serious problem on the frequency stability. Accordingly, it is necessary to analyze the effects of wind turbine on system interconnection and assess the optimum capacity of wind turbine that satisfies the most important principle of stable power supply. This paper have analyzed the effects of wind turbine capacity increases on the system and suggested the method of the capacity to achieve its steady operation. And It is applied to the Jeju island.

A Performance Simulation for Call Capacity of Base Station in CDMA Mobile System (CDMA Mobile System의 Base Station호 처리 용량 성능 시뮬레이션)

  • Lee, Dong-Myeong;Jeon, Mun-Seok;Lee, Cheol-Hui
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.5
    • /
    • pp.1253-1261
    • /
    • 1996
  • The base station (BS) of CDMA mobile system (CMS) provides mobile call services by controlling call processing functions. The call Processing part of the BS is divided into two components; the base station transceiver subsystem (BTS) and the base station controller (BSC). In this paper, we present the call capacity estimation of the BS about control signals and traffic data of calls by the simulation, and find the bottleneck points and problems which may occur in the BS. In order to estimate the call capacity, first we extract the major parameters for the modeling the BS. Second, we suggest the simulation model for the BS. Third, we estimate the simulation results by finding major objective factors such that the call blocking probability, the utilization ratio and the delay time in the traffic channel elements (TCEs), the BTS interconnection network (BIN)-COMA interconnection network (CIN) trunks, the transcoding channels and the CIN packet router.

  • PDF

SCATOMi : Scheduling Driven Circuit Partitioning Algorithm for Multiple FPGAs using Time-multiplexed, Off-chip, Multicasting Interconnection Architecture

  • Young-Su kwon;Kyung, Chong-Min
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.823-826
    • /
    • 2003
  • FPGA-based logic emulator with lane gate capacity generally comprises a large number of FPGAs connected in mesh or crossbar topology. However, gate utilization of FPGAs and speed of emulation are limited by the number of signal pins among FPGAs and the interconnection architecture of the logic emulator. The time-multiplexing of interconnection wires is required for multi-FPGA system incorporating several state-of-the-art FPGAs. This paper proposes a circuit partitioning algorithm called SCATOMi(SCheduling driven Algorithm for TOMi)for multi-FPGA system incorporating four to eight FPGAs where FPGAs are interconnected through TOMi(Time-multiplexed, Off-chip, Multicasting interconnection). SCATOMi improves the performance of TOMi architecture by limiting the number of inter-FPGA signal transfers on the critical path and considering the scheduling of inter-FPGA signal transfers. The performance of the partitioning result of SCATOMi is 5.5 times faster than traditional partitioning algorithms. Architecture comparison show that the pin count is reduced to 15.2%-81.3% while the critical path delay is reduced to 46.1%-67.6% compared to traditional architectures.

  • PDF

A Study on the Algorithm for Interconnection of PV System on Power Distribution System Considering Reliability (신뢰도를 고려한 태양광시스템의 배전계통 연계 알고리즘에 관한 연구)

  • Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.241-245
    • /
    • 2011
  • In this paper, when photovoltaic (PV) systems are connected to power distribution system, most effective capacity and connected-point of PV system are presented considering power distribution system reliability. The reliability model of PV system is presented considering the duration of sunshine. Also the model of time-varying load and reliability test system bus2 model are used. To simulate the effects of PV system, various cases are selected; (1) base case which is no connection of PV system to power distribution system when faults are occurred, (2) 3MW case which is 3[MW] connection of PV system (3) 4[MW] case, and (4) 20[MW] case which is 20[MW] connection of PV system to the bus of power distribution system. The capacity limit of connected PV system is settled to 14[MW] for all cases except case 4. The reliability for residential, general, industrial, and educational customer is evaluated.

Datacenter-Oriented Elastic Optical Networks: Architecture, Operation, and Solutions

  • Peng, Limei;Sun, Yantao;Chen, Min;Park, Kiejin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.11
    • /
    • pp.3955-3966
    • /
    • 2014
  • With the exponentially increasing Internet traffic and emergence of more versatile and heterogeneous applications, the design of datacenter networks (DCNs) is subject to unprecedented requirements for larger capacity and more flexible switching granularities. Envisioning Optical-Orthogonal Frequency Division Multiplexing (O-OFDM) as a promising candidate for such a scenario, we motivate the use of O-OFDM as the underlying switching technology in order to provide sufficient switching capacity and elastic bandwidth allocation. For this purpose, this article reviews the recent progresses of DCN deployment and assesses the scenario where the O-OFDM transmission and switching technology is employed in the underlying transport plane. We discuss the key issues of the datacenter-oriented O-OFDM optical networks, and in particular, elaborate on a number of open issues and solutions including system interconnection architecture, routing and resource assignment, survivability, and energy-efficiency.