• Title/Summary/Keyword: Intercomparison

Search Result 176, Processing Time 0.028 seconds

Verification of Harmonization of Dose Assessment Results According to Internal Exposure Scenarios

  • Kim, Bong-Gi;Ha, Wi-Ho;Kwon, Tae-Eun;Lee, Jun-Ho;Jung, Kyu-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.143-153
    • /
    • 2018
  • Background: The determination of the amount of radionuclides and internal dose for the worker who may have intake of radionuclides results in a variation due to uncertainty of measurement data and ingestion information. As a result of this, it is possible that for the same internal exposure scenario assessors could make considerably different estimation of internal dose. In order to reduce this difference, internal exposure scenarios for nuclear facilities were developed, and intercomparison were made to determine the harmonization of dose assessment results among the assessors. Materials and Methods: Seven cases on internal exposures incidents that have occurred or may occur were prepared by referring to the intercomparison excercise scenario that NRC and IAEA have carried out. Based on this, 16 nuclear facilities concerned with internal exposure in Korea were asked to evaluate the scenarios. Each result was statistically determined according to the harmonization discrimination criteria developed by IDEAS/IAEA. Results and Discussion: The results were evaluated as having no outliers in all 7 cases. However, the distribution of the results was spread by various causes. They can be divided into two wide categories. The first one is the distribution of the results according to the assumption of the intake factors and the evaluation factors. The second one is distribution due to misapplication of calculation method and factors related to internal exposure. Conclusion: In order to satisfy the harmonization criteria and accuracy of the internal exposure dose evaluation, it is necessary that exact guidelines should be set on low dose, and various intercomparison cases also be needed including high dose exposure as well as the specialized education. The aim of the blind test is to make harmonization evaluation, but it will also contribute to securing the expertise and high quality of dose evaluation data through the discussion among the participants.

Second intercomparison on electron paramagnetic resonance (EPR) retrospective dosimetry in Korea using hydroxyapatite

  • HyoJin Kim;Jae Seok Kim;Byeong Ryong Park;Seongjae Jang;Han-Ki Jang;Ki-Taek Han;Hoon Choi;Jeongin Kim;In Jung Kim;Yunho Kim;Wi-Ho Ha;Jungil Lee;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4576-4582
    • /
    • 2023
  • The Korea retrospective dosimetry (KREDOS)-electron paramagnetic resonance (EPR) group undertook an intercomparison investigation utilizing hydroxyapatite. This analysis involved four institutions: the Korea Institute of Radiological and Medical Sciences, Dongnam Institute of Radiological and Medical Sciences, Korean Association for Radiation Application, and Radiation Health Institute of Korea Hydro & Nuclear Power. Following the irradiation of the hydroxyapatite sample, the recorded build-up was analyzed. To validate the reliability of the EPR dosimetry findings and enhance its operational performance, a hydroxyapatite dose-response curve was plotted and dosimetry was performed for a blind sample. The proficiency of each laboratory was assessed by employing an interlaboratory comparison methodology. This involved a comparative analysis of the measurement results by calculating the relative bias, z-score, and En value. The results submitted by the participating laboratories demonstrated satisfactory ratings for doses of 1.006, 3.999, and 6.993 Gy. Following the second intercomparison, efforts to optimize their hydroxyapatite-EPR dosimetry systems are underway in the participating laboratories. The current assessment of hydroxyapatite dose yielded the foundational data required to establish the parameters of dental dosimetry. In future, the third intercomparison experiment will be conducted for exploring other materials.

Data intercomparison and determination of toxic and trace elements in Algae using Instrumental Neutron Activation Analysis (중성자방사화분석에 의한 Algae중의 독성미량원소의 정량 및 실험실간 비교검증)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Park, Kwang-Won;Lee, KiI-Yong;Yoon, Yoon-Yeol
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.346-353
    • /
    • 1999
  • For the non-destructive multi-elemental analysis of environmental and biological materials, instrumental neutron activation analysis (INAA) was applied for the determination of toxic and trace elements in a set of three Algae samples provided by the International Atomic Energy Agency (IAEA). The analytical quality control was evaluated by comparing the analytical results of two standard reference materials of the National Institute of Standards and Technology (NIST); Oyster Tissue (SRM 1566a) and Citrus Leaves (SRM 1572). According to given analytical procedure, the concentration of 15-25 elements including spiked elements such as As, Cd, Cr and Hg in Algae samples were determined. To identify and validate these results, a data intercomparison program using more than 35 analytical methods in 150 laboratories was carried out and the estimated statistical data are summarized. Result of INAA is favorable, therefore, it is illustrated that can be applied for routine analysis of essential and toxic elements in algae samples as well as analytical quality assurance.

  • PDF

Standardizing GC-FID Measurement of Nonmethane Hydrocarbons in Air for International Intercomparison Using Retention Index and Effective Carbon Number Concept

  • Liaw, Sheng-Ju;Tso, Tai-Ly
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.807-814
    • /
    • 1995
  • Accurate measurements of ozone precursors are required to understand the process and extent of ozone formation in rural and urban areas. Nonmethane hydrocarbons (NMHCs) have been identified as important ozone precursors. Identification and quantification of NMHCs are difficult because of the large number present and the wide molecular weight range encountered in typical air samples. A major plan of the research team of the Climate and Air Quality Taiwan Station (CATs) was the measurement of atmospheric nonmethane hydrocarbons. An analytical method has been development for the analysis of the individual nonmethane hydrocarbons in ambient air at ppb (v) and subppb(v) levels. The whole ambient air samples were collected in canisters and analyzed by GC-FID with $Al_2O_3$/KCl PLOT column. Our targeted for quantitative analysis 43 compounds that may be substantial contributors to ozone formation. The retention indices and molar response factors of some commercially available $C_2{\sim}C_{10}$ hydrocarbons were determined and used to identify and quantify air samples. A quality assurance program was instituted to ensure that good measurements were made by participating in the International Nonmethane Hydrocarbon Intercomparison Experiments (NOMHICE).

  • PDF

Intercomparison Study of the Neutron Personnel Dosemeters (중성자 개인선량계 상호비교)

  • Kim, Bong-Hwan;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.49-57
    • /
    • 1998
  • Domestic intercomparison study of the neutron personnel dosemeters was performed for the first time in Korea. Thirteen types of neutron dosemeters from twelve institutions took part in this intercomparison study and the $D_2O$ moderated Cf-252 source of KAERI was used for irradiation. Eight of the fifteen dosemeters submitted by each participant were divided into two groups and each group was irradiated with different doses of the simulated mixed fields of neutron and gamma. The participants assessed their dosemeter reading in terms of the personal dose equivalent, Hp(10), for both neutron and gamma dose. The ratio of the reported dose equivalent to the delivered dose equivalent for comparison between participants ranged from 0.55 to 1.34 for neutron, from 0.54 to 1.32 for gamma and from 0.75 to 1.20 for total dose. This intercomparison results show that all dosemeter processors, especially for neutron category, are able to pass the personnel dosemeter performance test which shall be enforced according to the ordinance of the MOST, No. 96-6.

  • PDF

Intercomparison Tests of National Standard Measuring System for Switching Impulse Voltage rated 500 kV (500 kV 개폐충격전압시스템의 비교시험)

  • Kim, I.S.;Kim, M.K.;Jeong, J.Y.;Moon, I.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.261-263
    • /
    • 2003
  • This paper represents the development of national standard(NS) for switching impulse(SI) voltage measuring system rated 500 kV. A traceability of the NS to the international standard could be achieved by the intercomparison test with CSIRO of Australia. According to the IEC 60060-2, a measurement uncertainty was assessed. As a result of the tests, a measurement uncertainty and step response characteristics were satisfied with the requisite for NS.

  • PDF

An Intercomparison of Atmospheric SO$_{2}$ Measurement Techniques (대기중 이산화황 관측 방법들의 실측 비교 연구)

  • 김경렬;이동수;이강웅
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.5
    • /
    • pp.587-591
    • /
    • 1996
  • An intercomparison experiment was implemented to assess the uncertainties and precisions om atmospheric SO$_{2}$ measurement techiques including a pulsed fluorescence (P-F), a diffusion-scrubber /ion chromatography (D-I), and a mist-chamber/ion chromatography (M-I). Each of those three techniques was investigated by researchers at Seoul National University, Yonsei University, and Hankuk University of Foreign Studies, respectively. The concentrations of atmospheric SO$_{2}$ were determined concurrently using three independent measurement techniques at the Seoul National University campus, Korea during Nov.22 to Dec.2, 1995. While the results from the P-F and D-I techinques showed the very close agreements (within +-5%) throughout the experiment period, M-I technique showed systematically smaller values (up to 30%) than the other two techniques. Although sources of larger discrepancy between different techniques were mot identified, the lower SO$_{2}$ values of the M-I method may be related to the errors associated with sample collection effciency, mass flow rate measurements, and standardization of ion chromatography.

  • PDF

Intercomparison of global water resource models: the impact of climate change and human activities on the runoff (글로벌 수자원 모형 결과 상호 비교: 기후변화 및 인간활동 영향으로 인한 유역별 유출 변화)

  • Ho, Hyunjoo;Lee, Sang Hyeon;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.307-307
    • /
    • 2018
  • 전 지구적으로 댐 건설과 가정, 공업 및 농업 용수의 사용 등 인간의 영향으로 유출량, 지하수, 토양수분 등의 다양한 수문요소가 변화를 보이고 있다. 이러한 인간의 영향은 기후변화의 영향과 함께 수문요소에 주요한 동인으로, 그 영향을 이해하고 전망할 필요가 있다. 본 연구는 Inter-Sectoral Impact Model Intercomparison Project에서 제공되는 이용 가능한 여러 글로벌 수자원 모형의 유출량 결과를 통해 기후변화 및 인간활동의 영향의 상대적 중요성 등을 분석했다. GFDL, HadGEM, IPSL, MIROC5에서 도출된 기후 시나리오를 기반으로 구동된 글로벌 수자원 모형 결과를 살펴봤으며, 글로벌 수자원 모형은 CLM, H08, LPJml 등을 포함한다.

  • PDF

Steric Sea Level Variability in the East Asian Seas estimated from Ocean Reanalysis Intercomparison Project Data

  • Chang, You-Soon;Kang, Min-Ji
    • Journal of the Korean earth science society
    • /
    • v.40 no.5
    • /
    • pp.487-501
    • /
    • 2019
  • In this study, steric height variability in the East Asian Seas (EAS) has been analyzed by using ocean reanalysis intercomparison project (ORA-IP) data. Results show that there are significant correlations between ocean reanalysis and satellite data except the phase of annual cycle and interannual signals of the Yellow Sea. Reanalysis ensemble derived from 15-different assimilation systems depicts higher correlation (0.706) than objective analysis ensemble (0.296) in the EAS. This correlation coefficient is also much higher than that of the global ocean (0.441). For the long-term variability of the thermosteric sea level during 1993-2010, a significant warming trend is found in the East/Japan Sea, while cooling trend is shown around the Kuroshio extension area. For the halosteric sea level, a dominant freshening trend is found in the EAS. However, below 300 m depth around this area, the signal-to-noise ratio of the linear trend is generally less than one, which is related to the low density of observation data.