• Title/Summary/Keyword: Inter-implant distance

Search Result 13, Processing Time 0.018 seconds

Esthetic restoration in continuous maxillary anterior area using immediate implant placement: A case report (임플란트 즉시 식립에 의한 연속된 상악 전치부의 심미적 수복 증례)

  • Lee, Ye Chan;Shim, Jun Sung;Lee, Jae Hoon;Lee, Keun Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.403-409
    • /
    • 2017
  • In the case of an extraction in the maxillary anterior region, immediate placement of implant-supported fixed prosthesis can be considered as a treatment option. Fewer surgical operations, reduced treatment time, and optimal availability of existing bone are obvious advantages of the method; however, when applied in the continuous maxillary anterior region, inter-implant distance must be carefully considered, as well as accurate diagnosis and treatment planning for predictable outcome. In this case report, immediate placement of two implants in the continuous maxillary anterior along with bone graft following the extraction of root rests, and the restoration of provisional and implant-supported fixed prosthesis on a 63-year-old patient had resulted in both esthetically and functionally satisfactory clinical outcomes.

Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques

  • Zhou, Ying;Li, Yong;Ma, Xiao;Huang, Yiqing;Wang, Jiawei
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.124-129
    • /
    • 2017
  • PURPOSE. This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS. Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS. In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION. The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.

Electrical Compound Action Potential: Effects of different parameters (전기 자극 청신경 복합활동전위: 변인 영향)

  • Heo, S.D.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Electrical compound action potential (ECAP) can be recorded on cochlear implant. This study will investigate stimulation and recording to enhance the efficacy of ECAP. 34 articles was used. We analyzed pulse and stimulating condition, artifact suppression, recording condition. The cathod-leading biphasic pulse was used with as short as possible pulse width and inter phase gap for the efficacy of neural firing, stable threshold and preventing neural degeneration. Around C-level was stimulated to apical, middle and basal turn of cochlea. Artifact was eliminated by forward-masking, template-subtraction technique. For clearer waveform, we need to change distance between stimulating and recording electrode, the gain of amplification, number of average.

  • PDF