• 제목/요약/키워드: Inter-calibration

검색결과 212건 처리시간 0.021초

자동차 안전운전 보조 시스템에 응용할 수 있는 카메라 캘리브레이션 방법 (Camera Calibration Method for an Automotive Safety Driving System)

  • 박종섭;김기석;노수장;조재수
    • 제어로봇시스템학회논문지
    • /
    • 제21권7호
    • /
    • pp.621-626
    • /
    • 2015
  • This paper presents a camera calibration method in order to estimate the lane detection and inter-vehicle distance estimation system for an automotive safety driving system. In order to implement the lane detection and vision-based inter-vehicle distance estimation to the embedded navigations or black box systems, it is necessary to consider the computation time and algorithm complexity. The process of camera calibration estimates the horizon, the position of the car's hood and the lane width for extraction of region of interest (ROI) from input image sequences. The precision of the calibration method is very important to the lane detection and inter-vehicle distance estimation. The proposed calibration method consists of three main steps: 1) horizon area determination; 2) estimation of the car's hood area; and 3) estimation of initial lane width. Various experimental results show the effectiveness of the proposed method.

모노펄스 레이다용 다채널 집적 수신기의 수신 채널 보정 (Receiving Channel Calibration of Multi-Channel Integrated Receiver for Monopulse Radar)

  • 박진성
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권3호
    • /
    • pp.109-114
    • /
    • 2024
  • 모노펄스 레이다용 다채널 집적 수신기 내에 존재하는 채널 간 간섭은 최근 수신기의 소형화 추세에 따라 그 영향성이 늘어날 것으로 예상된다. 따라서, 본 논문에서는 모노펄스 레이다에 적용되는 다채널 집적 수신기의 수신 채널간 간섭을 보정하여, 표적 각도 검출 성능 왜곡을 배제할 수 있는 방법을 제안한다. 이를 위하여 스위치, 방향성 결합기, 정합 부하, ADC(Analog to Digital Converter), 채널 보정 신호원 등을 이용하여 보정 하드웨어 구성을 제안하였다. 또한, 스위치와 보정 신호원을 제어하여 총 9개의 산란 파라미터를 획득하고, 안테나로부터 출력되는 모노펄스 신호와 채널 간 간섭이 존재하는 상태에서의 다채널 수신기를 통과한 모노펄스 신호 간의 수학적 관계를 이용하여 왜곡되지 않는 모노펄스 신호를 복원하는 방법을 제안하였다.

파노라믹 3D가상 환경 생성을 위한 다수의 카메라 캘리브레이션 (Multiple Camera Calibration for Panoramic 3D Virtual Environment)

  • 김세환;김기영;우운택
    • 전자공학회논문지CI
    • /
    • 제41권2호
    • /
    • pp.137-148
    • /
    • 2004
  • 본 논문에서는 영상기반 파노라믹 3D 가상 환경 (Virtual Environment: VE) 생성을 위해 회전하는 다수의 멀티뷰 카메라를 위한 캘리브레이션 방법을 제안한다. 일반적으로, 카메라 캘리브레이션 알고리즘은 카메라와 캘리브레이션 패턴 사이의 이 멀어질수록 획득되는 카메라 파라미터의 정확도가 상당히 저하되어 파노라마 영상 제작에는 부적합하다. 이러한 문제점을 극복하기 위해 멀티뷰 카메라의 렌즈간 그리고 회전하는 다수의 멀티뷰 카메라간의 기하학적인 상관 위치 관계를 이용하여 정확도를 높인다. 우선, Tsai의 캘리브레이션 알고리즘을 적용하여 획득된 카메라 파라미터를 카메라 렌즈간의 사전 기하 정보와 비교하여 그 오차에 기반한 인트라 카메라 캘리브레이션 (Intra-camera Calibration)을 수행한다. 그리고 가상 공간에 역투영된 3D point cloud에 ICP 알고리즘을 적용하여 인터 카메라 캘리브레이션 (Inter-camera Calibration)을 수행한다. 이를 확장하여, 다수의 카메라를 회전시켜 획득된 3D point cloud에 대해 기준 카메라의 위치를 중심으로 인터 카메라 캘리브레이션을 연속적으로 수행함으로써 회전하는 다수의 멀티뷰 카메라에 대한 캘리브레이션을 수행한다. 이와 같은 캘리브레이션 방법을 통해 중에서도 비교적 개선된 카메라 파라미터를 획득할 수 있기 때문에 파노라믹 3D 가상 환경을 생성하기 위한 정합과정에 사용할 수 있다. 또한, 실시간 3D 객체 추적 및 AR 응용 시스템 등의 다양한 AR 응용분야에 활용될 수 있다.

소닉노즐을 이용한 벨 푸루버의 국제비교 (Inter-comparison of Bell Prover using Sonic Nozzles)

  • 최해만;박경암
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.24-29
    • /
    • 2004
  • The inter-comparison of standards is required to be recognized the calibration results. The sonic nozzle package is developed to do inter-comparison of the bell preyer used to calibrate many gas flow meters for industries. Four national metrology institutes (KRISS, CMS, CENAM, NEL) were participated in this inter-comparison. The deviation of calibration data from the average value was small at the low flow rate and large at the high flow rate, respectively At the high flow rate, the deviation was larger than the expected value from uncertainties asserted by NMIs. This means there are some problems in the uncertainty evaluation and experiment procedures in some of the participated NMIs.

Evaluation of GSICS Correction for COMS/MI Visible Channel Using S-NPP/VIIRS

  • Jin, Donghyun;Lee, Soobong;Lee, Seonyoung;Jung, Daeseong;Sim, Suyoung;Huh, Morang;Han, Kyung-soo
    • 대한원격탐사학회지
    • /
    • 제37권1호
    • /
    • pp.169-176
    • /
    • 2021
  • The Global Space-based Inter-Calibration System (GSICS) is an international partnership sponsored by World Meteorological Organization (WMO) to continue and improve climate monitoring and to ensure consistent accuracy between observation data from meteorological satellites operating around the world. The objective for GSICS is to inter-calibration from pairs of satellites observations, which includes direct comparison of collocated Geostationary Earth Orbit (GEO)-Low Earth Orbit (LEO) observations. One of the GSICS inter-calibration methods, the Ray-matching technique, is a surrogate approach that uses matched, co-angled and co-located pixels to transfer the calibration from a well calibrated satellite sensor to another sensor. In Korea, the first GEO satellite, Communication Ocean and Meteorological Satellite (COMS), is used to participate in the GSICS program. The National Meteorological Satellite Center (NMSC), which operated COMS/MI, calculated the Radiative Transfer Model (RTM)-based GSICS coefficient coefficients. The L1P reproduced through GSICS correction coefficient showed lower RMSE and Bias than L1B without GSICS correction coefficient applied. The calculation cycles of the GSICS correction coefficients for COMS/MI visible channel are provided annual and diurnal (2, 5, 10, 14-day), but long-term evaluation according to these cycles was not performed. The purpose of this paper is to perform evaluation depending on the annual/diurnal cycles of COMS/MI GSICS correction coefficients based on the ray-matching technique using Suomi-NPP/Visible Infrared Imaging Radiometer Suite (VIIRS) data as reference data. As a result of evaluation, the diurnal cycle had a higher coincidence rate with the reference data than the annual cycle, and the 14-day diurnal cycle was the most suitable for use as the GSICS correction coefficient.

Calibration of the depth measurement system with a laser pointer, a camera and a plain mirror

  • Kim, Hyong-Suk;Lin, Chun-Shin;Gim, Seong-Chan;Chae, Hee-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1994-1998
    • /
    • 2005
  • Characteristic analysis of the depth measurement system with a laser, a camera and a rotating mirror has been done and the parameter calibration technique for it has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance. The calibration techniques to minimize the effect of such major parameters are proposed.

  • PDF

A 285-fsrms Integrated Jitter Injection-Locked Ring PLL with Charge-Stored Complementary Switch Injection Technique

  • Kim, Sungwoo;Jang, Sungchun;Cho, Sung-Yong;Choo, Min-Seong;Jeong, Gyu-Seob;Bae, Woorham;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권6호
    • /
    • pp.860-866
    • /
    • 2016
  • An injection-locked ring phase-locked loop (ILRPLL) using a charge-stored complementary switch (CSCS) injection technique is described in this paper. The ILRPLL exhibits a wider lock range compared to other conventional ILRPLLs, owing to the improvement of the injection effect by the proposed CSCS. A frequency calibration loop and a device mismatch calibration loop force the frequency error to be zero to minimize jitter and reference spur. The prototype chip fabricated in 65-nm CMOS technology achieves a $285-fs_{rms}$ integrated jitter at GHz from the reference clock of 52 MHz while consuming 7.16 mW. The figure-of-merit of the ILRPLL is -242.4 dB.

CTD 교정 시스템 구축 및 불확도 평가 (Establishment of CTD Calibration System and Uncertainty Estimation)

  • 이정한;황근춘;김은수;이승훈
    • Ocean and Polar Research
    • /
    • 제36권1호
    • /
    • pp.77-85
    • /
    • 2014
  • The quality control of ocean observations data is becoming a major issue as real-time observational data and information services have increased recently. Therefore, it is necessary for oceanographic instruments to calibrate. In this paper, we first introduce the CTD calibration system and traceability. Next, CTD calibration procedures and estimation of uncertainty of measurement are described. The expanded uncertainty (k = 2) of the temperature, pressure and conductivity are 0.$0.003^{\circ}C$, $6.0{\times}10^{-5}$ and 0.006 mS/cm respectively. Finally, the excellence of CTD calibration and its measurement capability has been proven by comparing the inter-calibration result of KIOST and Sea-Bird Electronics (SBE). CTD calibration residuals are less than ${\pm}0.0001^{\circ}C$, ${\pm}0.001$ MPa, ${\pm}0.0001$ S/m for SBE 3plus temperature sensor, SBE 19plus pressure sensor and SBE 4C conductivity sensor respectively.

EPMA를 이용한 U3Si/Al 조사 핵연료의 반응층 분석 (EPMA Analysis of Inter-reaction Layer in Irradiated U3Si-Al Fuels)

  • 정양홍;유병옥;김희문;박종만;김명한
    • 분석과학
    • /
    • 제17권4호
    • /
    • pp.355-362
    • /
    • 2004
  • 하나로 원자로에서 조사된 최대 선출력이 121 kW/m이고, 63 at%의 평균 연소도를 갖는 $U_3Si-Al$ 원심 분무 고출력 핵연료를 EPMA를 이용하여 파단면 관찰 및 반응층에 대한 핵분열 생성물을 분석 하였다. 조사된 고출력 $U_3Si-Al$ 핵연료를 EPMA로 화학 조성을 분석하기 위해 선행조건은 방사능 허용 한도가 $3{\times}10^{10}Bq$ 이하로 제한되는 EPMA 기기에 부합 될 수 있게 시험 시편을 최소화 하기 위한 작업이다. 시험 조건에 부합될 수 있는 시편의 제조를 위해 핵연료 천공 장치를 제작하였으며, 천공 장치를 사용하여 ${\Phi}1.57{\times}2mm$의 크기를 갖는 시료를 만들었다. 천공 된 시료를 파단 시편과 연마 시편으로 제조하여 파단면의 관찰 및 반응층(Inter-reaction layer)과 산화층에 대한 EPMA 분석을 수행하였다. 두께가 $16{\mu}m$인 반응층에 대한 평균값은 $UO_2$를 표준 시편으로 calibration한 경우의 조성은 $U_{2.84}$ Si $Al_{14}$ 이였으며, 시험 시편으로 calibration한 경우의 조성은 $U_{3.24}$ Si $Al_{14.1}$ 였다. 또한 반응층에서 핵분열 생성물의 조성을 분석하였으며, 반응층에서의 금속 석출물(metallic precipitates)의 생성은 확인할 수 없었다. 시험 시편의 산화층 조성은 $Ai_2O_3$ 임을 확인했다.

실거리 파라미터 교정식 복합센서 기반 3차원 거리측정 시스템 (3D Depth Measurement System based on Parameter Calibration of the Mu1ti-Sensors)

  • 김종만;김원섭;황종선;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 영호남 합동 학술대회 및 춘계학술대회 논문집 센서 박막 기술교육
    • /
    • pp.125-129
    • /
    • 2006
  • The analysis of the depth measurement system with multi-sensors (laser, camera, mirror) has been done and the parameter calibration technique has been proposed. In the proposed depth measurement system, the laser beam is reflected to the object by the rotating mirror and again the position of the laser beam is observed through the same mirror by the camera. The depth of the object pointed by the laser beam is computed depending on the pixel position on the CCD. There involved several number of internal and external parameters such as inter-pixel distance, focal length, position and orientation of the system components in the depth measurement error. In this paper, it is shown through the error sensitivity analysis of the parameters that the most important parameters in the sense of error sources are the angle of the laser beam and the inter pixel distance.

  • PDF