발목 관절 가동범위 측정을 위한 측정도구의 신뢰도 연구 (Reliability of measurement devices for measuring the ankle joint motion)

  • 홍완성;김기원
    • 대한정형도수물리치료학회지
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purposes of this study were to establish the concurrent validity of the universal goniometer and electronic inclinometer for ankle joint of motion, and to determine the inter-tester and the intra-tester reliability of these two instruments. Methods: Subjects were instructed 25 healthy subjects. Ankle range of motion was measured on two separate occasions 2 or 3 days by two physical therapists. Ankle dorsiflexion and plantarflexion was by using an universal goniometer and an electronic inclinometer. Results: The Pearson product-moment correlation between the two instruments was 0.78~0.80. The ICCs for inter-tester reliability ranged from 0.63 to 0.73 for universal goniometer and ranged from 0.81 to 0.88 for electric inclinometer. The ICCs for intra-tester reliability showed a wide variation(ICC=0.61 to 0.86). Conclusion: These findings indicate that the two instruments are reliable instruments for measuring ankle joint range of motion. The results also indicate that the two instruments can be used interchangeably for measuring ankle motions.

  • PDF

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

  • Hwang, Ui-jae;Ha, Sung-min;Jeon, In-chul;Jung, Sung-hoon;Choi, Kyu-hwan;Kim, Su-jung;Kwon, Oh-yun
    • 한국전문물리치료학회지
    • /
    • 제22권4호
    • /
    • pp.62-70
    • /
    • 2015
  • The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester's hand over the subject's clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B's measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

A Study on the Reliability and Validity of Measuring the Range of Motion of the Elbow Joint Using a Smartphone Application

  • Lee, Jun Cheol
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권3호
    • /
    • pp.65-72
    • /
    • 2018
  • The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.

엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구 (The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient)

  • 박선욱;김명수;배효선;차용호
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

주관절 가동범위 측정법에 대한 동시타당도와 신뢰도 (Concurrent Validity, Inter-Tester and Intra-Tester Reliability of Goniometric Measurement of Active Elbow Range of Motion Using 4 Different Types of Measuring Instruments)

  • 구애련;이충휘
    • 한국전문물리치료학회지
    • /
    • 제2권2호
    • /
    • pp.46-55
    • /
    • 1995
  • The purpose of this study was to assess the concurrent validity and reliability of goniometric measurement of joint motion. Subjects were 40 healthy university students. Measurements were performed by 4 inexperienced physical therapy students. Four different instruments were used and three readings were taken with each instrument in random order making a total of 12 readings for flexion of the right elbow of each subject. Goniometers used were 1. universal 2. fluid-based goniometer/inclinometer 3. digital LCD goniometer 4. electronic goniometer/torsiometer. The results were as follows: Concurrent validity was highest (r= .94) with the universal and digital LCD tools. Interrater reliability (Pearson Product Moment Correlation) was good for each tool. Interrater reliability calculated by ICC(2,1) was highest (.96) with the tensiometer and lowest (.78) with the digital LCD goniometer. Intrarater reliability calculated by ICC was excellent (${\geq}.90$) for all instruments. These results show that concurrent validity, intrarater and interrater reliability are very good in the used of all four types of goniometers/inclinometer/tensiometer, even with inexperienced raters. These results confirm the almost universal reliance on hand held goniometers for joint measurement by physical therapists as being a reliable practice. Further research should be done clinically with actual patients.

  • PDF

깃각 자동측정 프로그램의 신뢰도와 타당도 평가 (An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program)

  • 김종순
    • PNF and Movement
    • /
    • 제17권2호
    • /
    • pp.329-337
    • /
    • 2019
  • Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson's correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

스마트폰 경사계를 사용한 엉덩관절 가동범위의 측정 신뢰도 연구 (Reliability Study of Hip Range of Motion Measurement by Smartphone Inclinometer)

  • 양회송;정찬주;유영대;배세현
    • 대한통합의학회지
    • /
    • 제4권2호
    • /
    • pp.89-96
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.

정상 성인에 대한 정량적 무릎힘줄반사 검사의 측정자간 신뢰도 (Inter-Rater Reliability of Quantitative Knee Tendon Reflex Test for Healthy Subjects)

  • 김용욱;원종혁
    • 한국전문물리치료학회지
    • /
    • 제14권3호
    • /
    • pp.57-63
    • /
    • 2007
  • The purpose of this study was to evaluate inter-rater reliability of the amplitude and first knee extension angles in deep tendon reflex test by using an electrical hammer. Twenty-five healthy adults participated in the study. Compound muscle action potential is elicited by tapping the knee tendon with an electrical hammer in deep tendon reflex tests. The amplitude and knee extension angle were simultaneously measured. The mean value of the amplitude and the knee extension angles through three time trials for each tester, are used for determining the inter-rater and Intra-class Correlation Coefficients (ICCs) reliabilities. According to the results, the ICCs of the amplitude is .280 and that of the knee extension angle is .789. Pearson correlation coefficients of the amplitude of the action potential and the knee extension angles are .685, showing significant statistically moderate correlation. Inter-rater reliability in the amplitude was not significant. More objective and quantitative deep tendon reflex tests should be done to obtain higher reliability in further studies.

  • PDF

Inter-rater Reliability of Cervical Proprioception, Dynamic Balance and Dorsiflexion Range of Motion Ising STARmat®

  • Park, Ji-Won;Park, Seol
    • The Journal of Korean Physical Therapy
    • /
    • 제32권2호
    • /
    • pp.88-93
    • /
    • 2020
  • Purpose: This study examined the inter-rater reliability of cervical proprioception, dynamic balance ability, and ankle dorsiflexion range of motion using STARmat®, which is a practical clinical tool that can provide practitioners and patients with quantitative and qualitative results. Methods: Thirty healthy young subjects were enrolled in this study, and two well-trained physical therapists participated as a tester. Two testers measured the cervical joint position error at the starting position after neck flexion, extension, side bending, and rotation; three dynamic balance tests, including anterior excursion, anterior reaching with single leg balance, and posterior diagonal excursion; and ankle dorsiflexion range of motion using STARmat®. The intra-class correlation coefficient (ICC) was used to determine the inter-rater reliability of the tests. Results: The inter-rater reliability for the cervical proprioception ranged from moderate to good (0.66 to 0.83), particularly for flexion (0.82), extension (0.70), right side bending (0.73), left side bending (0.71), right rotation (0.83), and left rotation (0.66). For the dynamic balance, the inter-rater reliability ranged from good to excellent (0.87 to 0.91), particularly for anterior excursion (0.86), posterior diagonal excursion (0.87 to 0.89), and anterior reaching with a single leg balance (0.90 to 0.91). In addition, for the ankle dorsiflexion range of motion, the ICC for the inter-rater reliability ranged from 0.95 to 0.96. Conclusion: STARmat® is a reliable tool for measuring cervical proprioception, dynamic balance tests, and ankle dorsiflexion range of motion in healthy young adults.

색각검사법의 재현성 및 반복성평가 (Assessment of Reproducibility and Repeatability for Color Vision Test)

  • 주석희;이은희
    • 한국안광학회지
    • /
    • 제13권4호
    • /
    • pp.109-114
    • /
    • 2008
  • 목적: 본 연구는 색각검사법의 반복측정에 따른 결과의 재현성을 평가하기 위해 진행하였다. 방법: 연구 대상자는 선천성 색각이상을 가지고 있지 않은 일개 대학교 안경광학과 학생 30명이었다. 색각이상검사 종류는 한식색각검사와 Hans 15 hue 검사 그리고 Lanthony D 15 hue 검사를 선택하였고, 3명의 검사자를 비교하기 위한 검사에서는 이시하라검사도 추가하였다. 결과: 가성동색표에서는 모두 정상으로 분류되어졌으나, 색분별법에서는 1명이 약한청황색각이상을 보였다. 가성동색표는 3번의 측정 및 검사자간 결과값이 일치하였으며, 색분별법 반복 측정에서 경미한 오류들의 차이가 나타났다. 그러나 실제 색각이상자의 분류에 있어서는 반복측정에 따른 결과값이 차이는 나타나지 않았다. 결론: 각 검사자는 비교적 간단한 색각검사라도 좀더 숙련된 기술로 피험자를 대하는 것이 필요하다. 피험 자 역시 세 번의 측정으로 인한 경험에 의존하여 색각검사를 하기보다는 매 검사는 신중을 기해야 함이 요구되어 진다. 선별검사에서는 두 가지 검사의 병행이 요구되어진다.

  • PDF