• 제목/요약/키워드: Intensity modulated beam

검색결과 108건 처리시간 0.022초

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Deep inspiration breath-hold (DIBH) 적용한 림프절이 포함된 왼편 유방암의 방사선 치료계획에 따른 주변 장기 선량 평가

  • 정다이;강효석;최병준;박상준;이건호;이두상;안민우;전명수
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.27-35
    • /
    • 2017
  • 목 적: 왼편 유방암 환자의 경우 오른편 유방암 환자보다 심장과 폐 등 정상장기에 불필요한 선량이 일부 조사됨에 따라 부작용이 우려되고 있다. 이를 줄이기 위해 DIBH기법을 시행하고 있다. Conventional Radiation Therapy, Intensity Modulated Radiation Therapy, Volumetric Modulated Arc Therapy의 치료계획 방법에 따라 쇄골상 림프절과 내유 림프절을 포함한 왼편 유방암의 경우 주변 장기의 선량 값을 비교 평가하고자 한다. 대상 및 방법: 왼편 유방암 환자 중 쇄골상 림프절과 내유 림프절을 포함한 환자 8명을 대상으로 Free Breathing과 Deep inspiration breath-hold 기법을 적용하여 각각 CT-Simulation을 시행한다. 획득한 영상을 기반으로 체표윤곽을 그려 95 %$D_{max}$<110 %이 되도록 Conventional Radiation Therapy, Intensity Modulated Radiation Therapy, Volumetric Modulated Arc Therapy방법으로 계획하였다. Conventional Radiation Therapy는 쇄골상 림프절에 1문조사, 유방 부분에 접선 2문조사로 Field in Field 기법을 사용하였다. Intensity Modulated Radiation Therapy는 7개의 조사면으로 구성하였다. Volumetric Modulated Arc Therapy은 회전반경을 $290^{\circ}{\sim}179^{\circ}$으로 한 2 ARC를 이용하여 계획을 수행하였다. Eclipse의 선량체적용적을 참고하여 주변 정상 장기 선량을 분석하였다. 결 과: Deep inspiration breath-hold기법을 적용함으로 심장과 흉벽 사이의 간격은 평균 $1.6{\pm}0.6cm$ 증가하였다. 폐의 평균 선량은 $19.2{\pm}1.0Gy$로 Intensity Modulated Radiation Therapy에서 가장 작은 값이 나타났다. 심장의 $V_{30}(%)$$2.0{\pm}1.9$로 Intensity Modulated Radiation Therapy에서 가장 작은 값이었다. 좌전하행 관상동맥에서는 평균 선량이 $25.4{\pm}5.4Gy$로 Intensity Modulated Radiation Therapy에서 가장 작은 값으로 나타났다. 반대편 유방의 최대선량 값은 Intensity Modulated Radiation Therapy일 때 $29.7{\pm}4.3Gy$로 가장 작은 값으로 나타났다. 결 론: 주변 정상장기 선량의 값을 비교해 보았을 때, Intensity Modulated Radiation Therapy와 Volumetric Modulated Arc Therapy은 치료에 적용할 수 있는 값으로 나타났다. 이 중 Intensity Modulated Radiation Therapy가 적합한 치료계획 방법으로 사료된다.

  • PDF

Gamma Evaluation with Portal Dosimetry for Volumetric Modulated Arc Therapy and Intensity-Modulated Radiation Therapy

  • Kim, Jung-in;Choi, Chang Heon;Park, So-Yeon;An, HyunJoon;Wu, Hong-Gyun;Park, Jong Min
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.61-66
    • /
    • 2017
  • The aim of this study is to investigate the characteristics of portal dosimetry in comparison with the MapCHECK2 measurments. In this study, a total of 65 treatment plans including both volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) were retrospectively selected and analyzed (45 VMAT plans and 20 IMRT plans). A total of 4 types of linac models (VitalBeam, Trilogy, Clinac 21EXS, and Clianc iX) were used for the comparison between portal dosimetry and the MapCHECK2 measurements. The VMAT plans were delivered with two VitalBeam linacs (VitalBeam1 and VitalBeam2) and one Trilogy while the IMRT plans were delivered with one Clinac 21EXS and one Clinacl iX. The global gamma passing rates of portal dosimetry and the MapCHECK2 measurements were analyzed with a gamma criterion of 3%/3 mm for IMRT while those were analyzed with a gamma criterion of 2%/2 mm for VMAT. Spearman's correlation coefficients (r) were calculated between the gamma passing rates of portal dosimetry and those of the MapCHECK2 measurements. For VMAT, the gamma passing rates of portal dosimetry with the VitalBeam1, VitalBeam2, and Trilogy were $97.3%{\pm}3.5%$, $97.1%{\pm}3.4%$, and $97.5%{\pm}1.9%$, respectively. Those of the MapCHECK2 measurements were $96.8%{\pm}2.5%$, $96.3%{\pm}2.7%$, and $97.4%{\pm}1.3%$, respectively. For IMRT, the gamma passing rates of portal dosimetry with Clinac 21EXS and Clinac iX were $99.7%{\pm}0.3%$ and $99.8%{\pm}0.2%$, respectively. Those of the MapCHECK2 measurements were $96.5%{\pm}3.3%$ and $97.7%{\pm}3.2%$, respectively. Except for the result with the Trilogy, no correlations were observed between the gamma passing rates of portal dosimetry and those of the MapCHECK2 measurements. Therefore, both the MapCHECK2 measurements and portal dosimetry can be used as an alternative to each other for patient-specific QA for both IMRT and VMAT.

Quantifications of Intensity-Modulated Radiation Therapy Plan Complexities in Magnetic Resonance Image Guided Radiotherapy Systems

  • Chun, Minsoo;Kwon, Ohyun;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • 제46권2호
    • /
    • pp.48-57
    • /
    • 2021
  • Background: In this study, the complexities of step-and-shoot intensity-modulated radiation therapy (IMRT) plans in magnetic resonance-guided radiation therapy systems were evaluated. Materials and Methods: Overall, 194 verification plans from the abdomen, prostate, and breast sites were collected using a 60Co-based ViewRay radiotherapy system (ViewRay Inc., Cleveland, OH, USA). Various plan complexity metrics (PCMs) were calculated for each verification plan, including the modulation complexity score (MCS), plan-averaged beam area (PA), plan-averaged beam irregularity, plan-averaged edge (PE), plan-averaged beam modulation, number of segments, average area among all segments (AA/Seg), and total beam-on time (TBT). The plan deliverability was quantified in terms of gamma passing rates (GPRs) with a 1 mm/2% criterion, and the Pearson correlation coefficients between GPRs and various PCMs were analyzed. Results and Discussion: For the abdomen, prostate, and breast groups, the average GPRs with the 1 mm/2% criterion were 77.8 ± 6.0%, 79.8 ± 4.9%, and 84.7 ± 7.3%; PCMs were 0.263, 0.271, and 0.386; PAs were 15.001, 18.779, and 35.683; PEs were 1.575, 1.444, and 1.028; AA/Segs were 15.37, 19.89, and 36.64; and TBTs were 18.86, 19.33, and 5.91 minutes, respectively. The various PCMs, i.e., MCS, PA, PE, AA/Seg, and TBT, showed statistically significant Pearson correlation coefficients of 0.416, 0.627, -0.541, 0.635, and -0.397, respectively, with GPRs. Conclusion: The area-related metrics exhibited strong correlations with GPRs. Moreover, the AA/Seg metric can be used to estimate the IMRT plan accuracy without beam delivery in the 60Co-based ViewRay radiotherapy system.

레이저빔을 이용한 펄스변조 적외선탐색기 기만 (Laser-based Jamming of a Pulse Modulated Infrared Seeker)

  • 김성재;정춘식;신용산
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.179-188
    • /
    • 2019
  • Laser beam is directional and small in divergence angle so that it is well qualified to deliver high intensity infrared energy into a coming MANPADS threat for aircraft survivability. The threat will be deceived and loose tracking of a target when it is exposed to the laser beam modulated relevant to the track mechanism of the threat. The laser beam goes through scattering inside the seeker of the threat and reach the detector in a stray light form, which is a critical phenomenon enabling jamming of the seeker. The mechanism of the laser beam based jamming against a pulse modulated infrared seeker is shown. Simulations are carried out to support the understanding of how the jam technique works.

Dose Verification of Intensity Modulated Radiation Therapy with Beam Intensity Scanner System

  • Vahc, Young-Woo;Park, Kwangyl;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.248-251
    • /
    • 2002
  • The intensity modulated radiation therapy (IMRT) with a multileaf collimator (MLC) requires the conversion of a radiation fluence map into a leaf sequence file that controls the movement of the MLC during radiation treatment of patients. Patient dose verification is clinically one of the most important parts in the treatment delivery of the radiation therapy. The three dimensional (3D) reconstruction of dose distribution delivered to the target helps to verify patient dose and to determine the physical characteristics of beams used in IMRT. A new method is presented for the pretreatment dosimetric verification of two dimensional distributions of photon intensity by means of Beam Intensity Scanner System (BISS) as a radiation detector with a custom-made software for dose calculation of fluorescence signals from scintillator. The scintillator is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The BISS reproduces 3D- relative dose distribution from the digitized fluoroscopic signals obtained by digital video camera-based scintillator(DVCS) device in the IMRT. For the intensity modulated beams (IMBs), the calculations of absorbed dose are performed in absolute beam fluence profiles which are used for calculation of the patient dose distribution. The 3D-dose profiles of the IMBs with the BISS were demonstrated by relative measurements of photon beams and shown good agreement with radiographic film. The mechanical and dosimetric properties of the collimating of dynamic and/or step MLC system alter the generated intensity. This is mostly due to leaf transmission, leaf penumbra and geometry of leaves. The variations of output according to the multileaf opening during the irradiation need to be accounted for as well. These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planning for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

손상위험장기에 인접한 불규칙한 모양의 타겟 치료 시, 용적변조회전 방사선치료와 비동일평면상의 빔을 이용한 세기변조 방사선치료의 유용성 평가 및 비교 (Comparison of Volumetric Modulated Arc Therapy and Non-coplanar Fixed-field Intensity Modulated Radiation Therapy for Irregular Target adjacent to Organ At Risk)

  • 김경아;나경수;서석진;이제희
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.57-68
    • /
    • 2017
  • 목 적: 본 연구는 모양이 불규칙하고 손상위험장기(Organ At Risk, OAR)에 매우 인접한 타겟(Target)의 방사선 치료 시, 비동일평면상(Non-coplanar)의 빔(Beam)을 이용한 Fixed-field 세기변조 방사선치료(Intensity Modulated Radiation Therapy, IMRT)와 용적변조회전 방사선치료(Volumetric Modulated Arc Therapy, VMAT) 치료계획의 유용성을 평가 및 비교해 보고자 하였다. 대상 및 방법: 본원에서 True Beam STX(Varian Medical Systems, USA)를 이용하여 전체 두피(Whole Scalp), 부분적 두피(Partial Scalp), 그리고 전체 뇌실(Whole Ventricle)에 방사선 치료를 받은 환자 중 각 부위별로 2명 씩, 총 6명을 대상으로 하였다. VMAT 치료계획 시, Beamlet에 포함되는 OAR의 용적을 최소화하기 위해 Coplanar 또는 Non-coplanar 빔을 이용하였고, Fixed-field IMRT는 6명 모두 2개 이상의 카우치(Couch) 각도를 이용한 Non-coplanar IMRT(이하 ncIMRT)로 치료계획 하였다. 결 과: 양측 수정체, 양측 시신경, 시신경 교차, 그리고 뇌 줄기의 최대선량과 양측 안구와 해마의 평균선량을 측정하였고, 6명 모두 9개의 OAR 중 6개 이상에서 VMAT 치료계획이 ncIMRT보다 1.1배에서 8.2배가량 높은 선량 값을 나타내었다. 전체 두피와 부분적 두피의 치료 시, 20 Gy가 조사되는 뇌의 용적은 VMAT이 ncIMRT의 2배 이상이었고, 전체 뇌실의 치료 시에는 두 치료계획이 큰 차이를 보이지 않았다. 타겟 Coverage는 두 치료계획 모두 $PTV_{100%}=95%$를 만족시켰고, 타겟 내 최대선량과 치료 시 필요한 총 Monitor Unit(MU)은 ncIMRT가 VMAT보다 높았으며 두 치료계획 모두 임상적용을 위한 Gamma test 시행 결과, 2 mm/2 % 조건을 통과하였다. 결 론: 본 연구 결과, ncIMRT는 VMAT에 비해 치료 시 필요한 MU가 높아 치료시간과 장비의 로딩(Loading)을 증가시키므로 치료의 효율성은 다소 떨어지지만, VMAT과 비슷한 타겟 Coverage를 유지하면서, OAR의 선량은 훨씬 감소시키는 것을 알 수 있었다. 따라서 모양이 불규칙하고 OAR에 매우 인접해 있는 타겟의 방사선 치료 시에는 ncIMRT 치료계획을 고려해 볼 필요가 있다고 사료된다.

  • PDF

방사선수술 시 다엽 콜리메이터를 기초로 한 IMAT의 선량분포 (Dosimetric Characteristics of Multileaf Collimator-based Intensity-modulated Arc Therapy for Stereotactic Radiosurgery)

  • 윤상모;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제18권2호
    • /
    • pp.93-97
    • /
    • 2007
  • 본 연구는 세기 변조된 multiple noncoplanar arc를 이용한 방사선수술 기법을 평가하기 위해 고안되었다. 정위적 방사선수술은 0.5 cm resolution의 MLC가 장착된 6-MV X-ray beam을 사용하였다. 본 연구에서는 단일 중심점(single isocenter)으로 5 gantry-couch 조합을 이용한 intensity modulated arc therapy (IMAT)를 응용하였다. 저자들은 2 cm의 구형 표적용적에 대하여 $25{\times}25cm$ 아크릴 팬톰으로 선량분포 특성을 조사하였다. 단일 중심점을 이용한 방사선조사에서 구형의 표적에 대하여 비교적 적절한 선량분포를 얻을 수 있음을 확인할 수 있었다. 80%의 선량 곡선이 frontal, saglttal, transverse planes에서 표적 용적을 적절히 포함하였으며, 40%와 80% 선량곡선 사이는 $4.0{\sim}4.5mm$이었다. 이것은 cylindrical cone을 이용한 다른 연구자들의 선량분포와 유사한 결과였다. 따라서, 본 연구에서 사용한 방사선수술 기법을 비정형적 모양의 뇌내 표적에 대한 방사선수술시에 이용이 가능할 것으로 사료된다.

  • PDF

15 MV를 이용한 전립샘암 세기조절 방사선치료 시 빔의 개수에 따른 부작용 발생률에 관한 연구 (A Study on the Incidence of Side Effects according to the Number of Beams in Intensity-modulated Radiation Therapy for Prostate Cancer using 15 MV)

  • 이주아
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.481-487
    • /
    • 2023
  • 본 연구에서는 15 MV를 이용한 전립샘암의 세기조절방사선치료 시 빔의 개수에 따른 광중성자선량의 부작용 발생률을 분석하고자 한다. 전립샘암 세기조절방사선치료의 방사선치료계획설계는 1회 처방선량 220 cGy, 전체 치료 횟수는 33회로 총 7260 cGy로 수립하였다. 실험에 사용된 선형가속기는 Varian의 True Beam STx(Varian, USA)이며, 계획용 표적체적(Planning target volume; PTV)에 15 MV로 광중성자 선량이 발생되도록 하였다. 치료계획의 설계는 Eclipse System (Varian Ver 10.0, USA)을 사용하여 세기조절방사선치료 5, 7, 9 portals로 하였다. 광중성자 선량 측정을 위해 광자극발광선량계 (Optically stimulated luminescence albedo neutron dosimeter, Landauer Inc., USA)를 사용하였다. 세기조절방사선치료 5 portals 시 1,000명당 1.7명, 7 portals 시 1,000명당 1.8명, 9 portals 시 1,000명당 2.0명이 광중성자 선량으로 인하여, 갑상샘에 부작용을 나타낼 확률임을 산출하였다. 본 연구는 세기조절방사선치료 시 2차 피폭선량의 위험성을 연구하여, 향후 방사선의 확률적 영향과 관련된 의미 있는 자료로 활용될 수 있기를 기대한다.