• Title/Summary/Keyword: Intensity Diminution

Search Result 9, Processing Time 0.025 seconds

Numerical Analysis for a Simple Shape Silencer for Intensity Diminution of High Pressure Blast Flow Fields (고압 폭발 유동장의 강도 감소를 위한 간단한 형상의 소음기에 대한 수치해석)

  • Ko S. H.;Woo S. D.;Kang K. J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.91-94
    • /
    • 2004
  • A numerical analysis was made to investigate the intensity diminution of a simple silencer for high pressure blast flow fields. Reynolds-Averaged Wavier-Stokes equations were solved for an axisymmetric computational domain constructed by multi block Chimera grids. A blast flow field without the silencer was also calculated to validate the present numerical method. The evolution of high pressure blast flow fields was observed by depicting calculated contours of pressure and Mach number. It was found that the tested silencer could achieve 76 percent intensity diminution.

  • PDF

An Experimental Study on the Thermal Properties of High Strength Concrete in the Range of $40{\sim}100MPa$ at High Temperature (고온시 $40{\sim}100MPa$ 범위의 콘크리트 열적특성에 관한 실험적 연구)

  • Kim, Heung-Youl;Jeon, Hyun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.425-428
    • /
    • 2006
  • In order to estimate the reduction of laodbearing capacity, followed by the attributive change of heat while high strength concrete structure is revealed on fire it is necessary to evaluate, it is necessary to evaluate the property of material under high temperature such as thermal conductivity, specific heat, compressive strength, modulus of rigidity and diminution figure. Therefore, this study is for the purpose of presenting evaluation data for the analysis of thermal behavior about the high strength concrete material under high temperature, through the experiment by manufacturing concrete(40, 50, 60, 80, 100 MPa) commonly used in the construction field. As a result of the study, in the case of physical attribute, it demonstrates a greater fluctuation of change than the one of 30 MPa concrete. In case of specific heat, the high strength concrete, shown the serious diminution between $500{\sim}600^{\circ}C$, presents the thermal change area corresponding to the change of high strength concrete. In compressive strength, regardless of intensity of concrete, all of them show the first intensity loss between normal temperature and $100^{\circ}C$, the dramatic loss beyond $400^{\circ}C$. The concrete weighing above 50 MPa shows a twice lower dramatic intensity loss than the one weighing $30{\sim}40MPa$. The concrete ranging from $60{\sim}80MPa$, shows the biggest diminution of modulus of elasticity under $400^{\circ}C$, which implies the structural unstability of temperature.

  • PDF

Decolorization of Rhodamine B Using UV/$TiO_2$ System (UV/$TiO_2$ 시스템을 이용한 Rhodamine B의 색도 제거)

  • 박영식;나영수;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.59-64
    • /
    • 2002
  • The photocatalytic decolorization of the Rhodamine B (RhB) was studied using a UV/TiO$_2$ reactor. Yakuri titanium dioxide(anatase) was used as the suspended photocatalyst and proved to be effective for decolorization irradiated with UV light (254 mm). The photocatalyzed dioxide concentrations, light intensity and air flow rates. In 0.01 mM RhB, color could be completely photodegraded after 3 hours. Absorption spectrum of an aqueous solution containing RhB showed a continued diminution of the RhB concentration in the solution bulk : concomitantly, no new absorption peaks appeared. This confirmed the decolorization of RhB, i.e., the break up of the chromopore. The optimum loaded titanium dioxide for the decolorization was 0.75 g/(equation omitted). The light intensity showed exponential decay with distance. The decay of light intensity of RhB solution showed different tendency from TiO$_2$. These results suggested that the photocatalytic decolorization of dyes may be available method for decolorizing in wastewater.

A Study on Light-shelf system based on IT in Housing Space -Focus on Lighting Energy Saving- (주거공간을 위한 IT결합 광선반시스템 개발 연구 -조명에너지 저감을 중심으로-)

  • Ahn, Hye-Young;Lee, Heang-Woo;Kim, Yong-Seong
    • KIEAE Journal
    • /
    • v.13 no.1
    • /
    • pp.133-140
    • /
    • 2013
  • The purpose of this study was to test the effectiveness of the light-shelf system combined with IT to save lighting energy in resident space. According to the multiple variables that affected intensity of illumination, various experiments were designed and conducted. The main findings of this study were following: (1)the optimal level of light-shelf system was formulated which met the appropriate range of intensity of illumination in living-room; (2)although the mixed light-shelf system indicated a high performance, it could often provide discomforts to residents according to the degree of exposure; (3)artificial lights using light-shelf system combined with IT showed a higher effectiveness than those using fixed light-shelf system displayed. This study provided initial information of light-shelf system formative processes that could contribute to the lighting energy diminution. Future studies should focus more on multiple approaches regarding different types of resident space planning.

The Effects of Decompression Therapy by Fixed Pelvic System on Low Back Pain During Pregnancy (골반고정장치에 의한 감압치료가 임산부 요통환자의 통증, 일상생활 제한 및 요추만곡에 미 치는 영향에 관한 연구)

  • Kim, Hee-Ra;Kim, Yoon-Shin;Kim, Seong-Ho;Kim, Myung-Joon
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Background and Purpose : This study serves the purpose to present the effective way on back pain therapy for women during their pregnancy by comparing and analyzing the effects influencing on pain index, limits on daily life, and diminution of lumbar curve, when having treated for 6 weeks, dividing into therapy group, applied by decompression therapy on spine without unnecessary effects on the pregnant women and their fetus and the existent general physiotherapy group, applied on diminution of their back pain. Subject & methods : We made impregnate women of 30(25${\sim}$34years), as the subject of this study, who understood, and agreed with, this study, among pregnant women who were diagnosed as back pain. Pain intensity, limit index on daily life, and lumbar curve test, prior to experiment was implemented as paired t-test, comparison of the difference of average by each group before and after experiment was analysed as independent t-test, and statistical examination level was set up as 0.05. Results : The difference of average of pain and limit on daily life between the group, SDTG(spinal decompression therapy group), and the group, GPTG(general physical therapy group), before and after experiment was diminished as much as 44.4% and 16.79% each after completed 6 weeks' experiment, limit on daily life in both groups showed as much as 37.2% and 21.5% each, in the end, they statistically showed conspicuous difference(p<.05). Comparison of lumbar curves between both groups, SDTG and GPTG, before and after experiment, were diminished from -23.13${\pm}$4.85 to -15.66${\pm}$3.71, and there was no remarkable difference(p<.05). Conclusion : As, in this study, decompression therapy is more effective than general physical therapy with pregnancy low back pain in pain, limitation of daily life, lumbar curve.

  • PDF

The effects of Ultrasound on the Platelet of Rats (초음파가 생쥐의 혈소판에 미치는 영향)

  • Cho, Kwang-Ho;Park, Sang-Ock;Park, Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.139-149
    • /
    • 2001
  • We found out that there exists threshold dose for the decreased platelet count when we apply change of the platelet count to the defense of the ultrasound experiment. Those diminution is definite effects from the defense of the ultrasound. The number of the platelet count is decreased when we are exposed to ultrasound simultaneously. This should not be occurred. It is easy to use the number of the platelet count in the measurement of the biological dosage and intensity in high dosage relatively due to definite quantative relationship. The biological index to understand synergic effects. which are present when two harmful environmental factors are operating at the same time is functionally assending and antagonistic. There are scattered many factors as physical, Chemical, or physiochemically elements which are harmful to human body in the environment in consideration of ultrasound and the other factors. This experiment is demonstrating that we can use the change of the platelet as an index representing synergic effects of ultrasound.

  • PDF

A Retrospective Analysis of MRI-verified 29 Cases of Transverse Myelitis (자기공명촬영으로 확인된 횡단성 척수염 29례에 대한 후향적 분석)

  • Kim, Young-Rae;Song, Jun-Hyeok;Park, Hyang-Kwon;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1642-1649
    • /
    • 2000
  • Objectives : Transverse myelitis(TM) is characterized by bilateral motor, sensory, and autonomic dysfunction of the spinal cord in the absence of pre-existing neurologic disease. It is an uncommon but not rare condition. But it remains as poorly understood syndrome not only etiologically but also in terms of its clinical behavior. Neurosurgically, It is often quite difficult to distinguish from other surgical intramedullary lesions. We present our clinical experiences of TM in order to assess its clinical behavior and to define the radiological characteristics that can distinguish TM from other intramedullary lesions. Methods : From June 1991 to May 1997, twenty-nine patients with transverse myelitis were admitted to our department. All cases revealed acute or subacute syndrome of non-compressive myelopathy and intramedullary lesions in the MRI. We analyze the radiological data and medical records retrospectively. Results : Patients ranged in age from 16 to 66 years, with 22 males and 7 females. Mean follow-up period was 53 months. For the offending levels, cervical was 5, thoracic 21, and lumbar 3 in number. The patients who presented the return of symptoms after a diminution or abatement of initial symptoms were 7(24%). In the MRI, TM showed typical characteristics of high signal intensity lesions in the center of spinal cord in T2 weighted images and low- to iso-signal intensity in T1 weighted images. A focal nodular enhancement pattern was observed in 58.6%(17/29) of the patients. MR follow-up studies were done in the 21 patients and radiological improvement were verified. Biopsies were done in 3 patients. Normal to good outcome was achieved in 62% of the patients. Conclusion : Transverse myelitis has characteristic radiological findings that can be distinguished from other intramedullary lesions. In our series, it is associated with significant recurrence rates thus, should not be considered a selflimiting disease with good prognosis.

  • PDF

A Comparative Study of Sulfate and Chloride Intrusion in Mortar Sections: An Approach Using Laser Induced Breakdown Spectroscopy and Ion Exchange Membrane (LIBS와 이온교환막을 활용한 모르타르 단면 침투 황산염과 염화물 분석)

  • Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.3
    • /
    • pp.221-229
    • /
    • 2023
  • This research aimed to conduct an empirical assessment of the penetration of chloride and sulfate ions into mortar sections using an anion exchange membrane(AEM) and laser-induced breakdown spectroscopy(LIBS). The study involved a simultaneous ion chromatography(IC) analysis and LIBS analysis performed on mortars immersed in varying concentrations of chloride and sulfate. The findings revealed that at the wavelengths specific to Chloride(837.59nm) and Sulfur(921.30nm), the LIBS intensity achieved using AEM surpassed that obtained with a paper substrate at equivalent penetration concentrations. A robust correlation was confirmed between LIBS intensity and chloride ion concentration. Furthermore, when juxtaposed with IC analysis concentration outcomes at identical depths, the AEM displayed a higher intensity. The research noted an enhancement in LIBS intensity and a diminution in errors within the low-concentration section when deploying AEM. However, for the Sulfur wavelength of 921.3nm, there remains a need to augment the sensitivity of the LIBS signal within the low-concentration section in future studies. The findings underscore the potential of employing AEM and LIBS for precise analysis of chloride and sulfate ion penetration into mortar sections. This strategy can aid in bolstering assessment precision and mitigating errors, particularly in regions with low concentrations. It is recommended to further research and develop methods to amplify the sensitivity of the LIBS signal for sulfur detection in low-concentration sections. In sum, the study accentuates the significance of employing advanced techniques like AEM and LIBS for efficacious and precise analysis in the domain of mortar section assessment.

Climate change impact on seawater intrusion in the coastal region of Benin

  • Agossou, Amos;Yang, Jeong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.157-157
    • /
    • 2022
  • Recent decades have seen all over the world increasing drought in some regions and increasing flood in others. Climate change has been alarming in many regions resulting in degradation and diminution of available freshwater. The effect of global warming and overpopulation associated with increasing irrigated farming and valuable agricultural lands could be particularly disastrous for coastal areas like the one of Benin. The coastal region of Benin is under a heavy demographic pressure and was in the last decades the object of important urban developments. The present study aims to roughly study the general effect of climate change (Sea Level Rise: SLR) and groundwater pumping on Seawater intrusion (SWI) in Benin's coastal region. To reach the main goal of our study, the region aquifer system was built in numerical model using SEAWAT engine from Visual MODFLOW. The model is built and calibrated from 2016 to 2020 in SEAWAT, and using WinPEST the model parameters were optimized for a better performance. The optimized parameters are used for seawater intrusion intensity evaluation in the coastal region of Benin The simulation of the hydraulic head in the calibration period, showed groundwater head drawdown across the area with an average of 1.92m which is observed on the field by groundwater level depletion in hand dug wells mainly in the south of the study area. SWI area increased with a difference of 2.59km2 between the start and end time of the modeling period. By considering SLR due to global warming, the model was stimulated to predict SWI area in 2050. IPCC scenario IS92a simulated SLR in the coastal region of Benin and the average rise is estimated at 20cm by 2050. Using the average rise, the model is run for SWI area estimation in 2050. SWI area in 2050 increased by an average of 10.34% (21.04 km2); this is expected to keep increasing as population grows and SLR.

  • PDF