증기발생기 전열관 와전류검사용 국내 개발 보빈탐촉자 적용성 분석 (Determination of Availability of Domestic Developed Bobbin Probe for Steam Generator Tube Inspection)

  • 김인철;주경문;문용식
    • 한국압력기기공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.19-25
    • /
    • 2011
  • Steam Generator(SG) tube is an important component of Nuclear Power Plant(NPP), which is the pressure boundary between the primary and secondary systems. The integrity of SG tube has been confirmed by the eddy current test every outage. The eddy current technique adopting bobbin probe is currently the primary technique for the steam generator tubing integrity assesment. The bobbin probe is one of the essential components which consist of the whole ECT examination system and provides us a decisive data for the evaluation of tube integrity. Until now, all of the ECT bobbin probes in Korea which is necessary to carry out inspection are imported from overseas. However, KHNP has recently developed the bobbin probe design technology and transferred it to domestic manufacturers to fabricate the probes. This study has been conducted to establish technical requirements applicable to the steam generator tube inspection using the bobbin probes fabricated by the domestic manufactures. The results have been compared with the results obtained by using foreign probe to identify the availability to the steam generator tube inspection. As a result, it is confirmed that the domestic bobbin probe is generally applicable to SG tube inspection in the NPPs.

원자력 발전소용 벨로우즈 글로브 밸브에 대한 구조 건전성 평가 (The Evaluation of the Structural Integrity of Bellows Globe Valve for Nuclear Power)

  • 정철섭
    • 한국산학기술학회논문지
    • /
    • 제7권6호
    • /
    • pp.1034-1039
    • /
    • 2006
  • 본 논문은 내진등급 IIA 글로브 밸브의 지진하중에 대한 구조 건전성을 평가하였다. 밸브 구조물을 3차원 모델링하여 유한요소법을 사용하여 모달 해석 및 등가 정적 응력해석을 수행하였다. 모달 해석 결과 구조물은 충분히 강건하므로 지진 가속도 값을 사용한 등가 정적 응력해석이 가능하였다. 정적 응력 해석에서 구한 응력을 조합하여 원자력 규격집에 근거한 허용기준에 따라 밸브의 구조 건전성을 평가하였다. 지진하중에서 발생한 응력값이 허용값 아래에 분포하므로 글로브 밸브 구조물은 구조적 건전성을 유지할 수 있다고 평가할 수 있다.

  • PDF

Electrical fire simulation in control room of an AGN reactor

  • Jyung, Jae-Min;Chang, Yoon-Suk
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.466-473
    • /
    • 2021
  • Fire protection is one of important issues to ensure safety and reduce risks of nuclear power plants (NPPs). While robust programs to shut down commercial reactors in any fires have been successfully maintained, the concept and associated regulatory requirements are constantly changing or strengthening by lessons learned from operating experiences and information all over the world. As part of this context, it is necessary not only to establish specific fire hazard assessment methods reflecting the characteristics of research reactors and educational reactors but also to make decisions based on advancement encompassing numerical analyses and experiments. The objectives of this study are to address fire simulation in the control room of an educational reactor and to discuss integrity of digital console in charge of main operation as well as analysis results through comparison. Three electrical fire scenarios were postulated and twenty-four thermal analyses were carried out taking into account two turbulence models, two cable materials and two ventilation conditions. Twelve supplementary thermal analyses and six subsequent structural analyses were also conducted for further examination on the temperature and heat flux of cable and von Mises stress of digital console, respectively. As consequences, effects of each parameter were quantified in detail and future applicability was briefly discussed. On the whole, higher profiles were obtained when Deardorff turbulence model was employed or polyvinyl chloride material and larger ventilation condition were considered. All the maximum values considered in this study met the allowable criteria so that safety action seems available by sustained integrity of the cable linked to digital console within operators' reaction time of 300 s.

Rancho Seco Transient에 대한 고리 1호기 원자로용기의 건전성 평가 (Integrity evaluation of Kori 1 reactor vessel for Rancho Seco transient)

  • 정명조;박윤원;이정배
    • 대한기계학회논문집A
    • /
    • 제21권7호
    • /
    • pp.1089-1096
    • /
    • 1997
  • In this paper, Rancho Seco transient which is reported as a typical pressurized thermal shock event is postulated to be occuring in the Kori unit 1 plant, the oldest nuclear power plant in Korea. For the given material properties, transient history such as temperature and pressure, and postulated flaw, the stress distribution is obtained to calculate stress intensities for a wide range of assumed crack sizes. The stress intensities are compared with the fracture toughness, which is determined using the material properties and the distribution of the nil ductility transition temperature, to determine if cracking is expected to occur during the transient. The allowable operating year for the transient is determined and the evaluation results are discussed.

철도화차용 용접구조대차의 건전성평가에 관한 연구 (Integrity evaluation of the welded structure bogie for the railway freight car)

  • 홍재성;함영삼;정흥채;백영남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 2005
  • Some bogie frames manufactured in 1999, 2000 year have the fatal problem. Three or four years later, the cracked end beam among them have discovered in 2002, 2003 year. The crack situation of the end beam have a bad effect on brake system. In that case, the cars would be in danger of derailment. To improve the end beam, a research of covering the whole field of welded type bogie frame was started. Main line real tests were performed at Young-Dong line. The stress of main positions for bogie frame was measured. Also up-down direction and left-right direction vibration acceleration of the bogie frame were measured. At this time the tests were performed for the three types bogie. The test result concludes that the crack cause of the end beam is not brake load but vibration at running mainly. It is estimated that the life of the improved car which end beam reinforced is safe within the car permitted life(25 years). The improvement methods of the end beam are presented by construction modification, parts modification. The integrity evaluation is inspected by analysis the real line test results, the improvement methods of the end beam.

  • PDF

다변수 메트릭 모델을 이용한 식장산 계곡천의 생태 건강성 평가 (Ecological Health Assessment of Mountainous Stream in Mt. Sik-Jang using Multi-metric Models)

  • 배대열;김유표;안광국
    • 한국물환경학회지
    • /
    • 제24권2호
    • /
    • pp.156-163
    • /
    • 2008
  • This study was to introduce a methodology of ecological health assessment for efficient management and to provide some diagnostic results of the survey. We evaluated ecological health assessment at five sampling locations of Sikjang Mountainous Stream using the index of biological integrity (IBI) and Qualitative Habitat Evaluation Index (QHEI) during May - October 2006. The health condition, based on the IBI model, averaged 32 and varied from 27 to 37 depending on the sampling sites. Thus, the stream health was judged as "good" to "fair" conditions. IBI values showed slight differences between upstream and downstream sites. Whereas, QHEI values varied from 75 (fair condition) to 196 (excellent condition) and QHEI at St. 4~5, indicating the downstream reach had significantly lower than the headwater site (St.1). Regression analyses also showed that QHEI values had a linear decrease from the headwater to downstream. This result indicated that habitat quality was rapidly degradated by human influence. Overall, data of IBI and QHEI suggested that the stream health was maintained well in the present but the habitat and biological quality were partially degradated in the downstream. So, the human interference should be minimized to protect the downstream environment.

A Review of Stream Assessment Methodologies and Restoration: The Case of Virginia, USA

  • Bender, Shera M.;Ahn, Chang-Woo
    • Environmental Engineering Research
    • /
    • 제16권2호
    • /
    • pp.69-79
    • /
    • 2011
  • Rapid population growth and land use changes have severely degraded streams across the United States. In response, there has been a surge in the number of stream restoration projects, including stream restoration for mitigation purposes. Currently, most projects do not include evaluation and monitoring, which are critical in the success of stream restoration projects. The goal of this study is to review the current status of assessment methodologies and restoration approaches for streams in Virginia, with the aim of assisting the restoration community in making sound decisions. As part of the study, stream restoration projects data from a project in Fairfax County, Virginia was assessed. This review revealed that the stream assessment methodologies currently applied to restoration are visuallybased and do not include biological data collection and/or a method to incorporate watershed information. It was found from the case study that out of the twenty nine restoration projects that had occurred between 1995 and 2003 in Fairfax County, nineteen projects reported bank stabilization as a goal or the only goal, indicating an emphasis on a single physical component rather than on the overall ecological integrity of streams. It also turned out that only seven projects conducted any level of monitoring as part of the restoration, confirming the lack of evaluation and monitoring. However, Fairfax County has recently improved its stream restoration practices by developing and incorporating watershed management plans. This now provides one of the better cases that might be looked upon by stakeholders when planning future stream restoration projects.

철도차량 구조물의 확률론적 피로수명 평가 (Probabilistic Fatigue Life Evaluation of Rolling Stock Structures)

  • 구병춘;서정원
    • 한국자동차공학회논문집
    • /
    • 제11권5호
    • /
    • pp.89-94
    • /
    • 2003
  • Rolling stock structures such as bogie frame and car body play an important role for the support of vehicle leading. In general, more than 25 years' durability is needed for them. A lot of study has been carried out for the prediction of the fatigue life of the bogie frame and car body in experimental and theoretical domains. One of the new methods is a probabilistic fatigue lift evaluation. The objective of this paper is to estimate the fatigue lift of the bogie frame of an electric car, which was developed by the Korea Railroad Research Institute (KRRI). We used two approaches. In the first approach probabilistic distribution of S-N curve and limit state function of the equivalent stress of the measured stress spectra are used. In the second approach, limit state function is also used. And load spectra measured by strain gauges are approximated by the two-parameter Weibull distribution. Other probabilistic variables are represented by log-normal and normal distributions. Finally, reliability index and structural integrity of the bogie frame are estimated.

플랜트 승압펌프 재순환 배관 용접부의 용접비드에 의해 발생한 감육결함 분석 및 건전성 평가 (Analysis of Weld Beads for Wall Thinning Defects in the Weld Zone of the Boost Pump Recirculation Pipe for Power Plants and Evaluation of Their Integrity)

  • 남기우;안석환;도재윤
    • 한국해양공학회지
    • /
    • 제24권4호
    • /
    • pp.38-46
    • /
    • 2010
  • The wall thinning phenomenon of pipes was simulated as metal loss due to erosion and corrosion. Such wall thinning defects in the pipes of power plants are a very important safety consideration. In this study, we analyzed wall thinning defects that occurred by weld bead of weld zone of boost pump recirculation pipe. From the results of the analysis of pipe failures, numerical analysis was performed by Fluent v6.3.26 using the standard k-$\varepsilon$ model of the weld bead shape, such as an elliptical or a spherical shape, on the inner wall of the pipe. Using the results obtained, we showed the overlap effect by cavitations corrosion and erosion-corrosion at the bottom of the wall-thinning defect.

연성해석을 이용한 CNG 차량 압력 용기용 밸브의 안전성 평가 (Safety Evaluation of a Cylinder Valve for Compressed Natural Gas Vehicle Pressure Vessels using Fluid-structure Interaction Analysis)

  • 이효렬;안중환;김복만;김화영
    • 한국생산제조학회지
    • /
    • 제23권2호
    • /
    • pp.103-108
    • /
    • 2014
  • Growing concerns about environmental pollution have led to an increase in the demand for compressed natural gas (CNG) vehicles in recent years. CNG vehicles are equipped with a cylinder valve installed in a high-pressure vessel to control the CNG flow. The cylinder valve must meet high quality safety standards because the pressure vessel stores high-pressure CNG. Therefore, safety evaluation of the cylinder valve is necessary to ensure the safety of CNG vehicles. In this study, fluid-structure interaction analysis for the structural integrity of the cylinder valve were conducted using a commercial finite element analysis code(ANSYS WORKBENCH V14). The CFD analysis was performed using a steady-state technique according to the inlet and outlet pressures in order to predict the pressure distribution. Structural analysis was performed by a static structure technique at the maximum working pressure to evaluate the structural integrity of the cylinder valve. From the results, the safety factor of the valve component is between 1.57 and 21.5.