• 제목/요약/키워드: Integrated Measuring System

검색결과 225건 처리시간 0.029초

형상 검사를 위한 multiple-sensor 측정 시스템의 캘리브레이션 연구 (Calibration off multiple-sensor measuring system for efficient visual inspection)

  • 김승만;손석배;이관행
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.579-582
    • /
    • 2002
  • In acquiring the surface information of a part, two types of measuring machines have been used: contact type and non-contact type. Since each measuring device has the pres and cons, an integrated measuring system is proposed to acquire the optimal point data. In order to implement the integrated measuring system, the relationship of coordinate systems between each measuring device should be established. In this paper, a new datum fixture and a calibration method for the multiple-sensor measuring system are proposed. The datum fixture is designed to interface two machines, a CMM and a laser scanner. The position of the datum fixture is calibrated by the axis information off motorized rotation stage which is used for a part setup.

  • PDF

SaaS(Software as a Service) 기반 지방유적도시 구조물 유지관리계측 통합모니터링시스템 구현 (Implementation of an Integrated Monitoring System for Constructional Structures Based on SaaS in Traditional Towns with Local Heritage)

  • 민병원;오용선
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2015년도 춘계 종합학술대회 논문집
    • /
    • pp.15-16
    • /
    • 2015
  • Measuring sensor, equipment, ICT facilities and their software have relatively short life time comparing to constructional structure so that we should exchange or fix them continuously in the process of maintenance and management. In this paper, we propose a novel design of integrated maintenance, management, and measuring monitoring system applying the concept of mobile cloud. For the sake of disaster prevention for constructional structures such as bridge, tunnel, and other traditional buildings in the village of local heritage, we analyze status of these structures in the long term or short term period as well as disaster situations. Collecting data based on mobile cloud and analyzing future expectations based on probabilistic and statistical techniques, we implement our integrated monitoring system for constructional structures to solve these existing problems. Final results of this design and implementation are basically applied to the monitoring system for more than 10,000 structures spread over national land in Korea. In addition, we can specifically apply the monitoring system presented here to a bridge of timber structure in Asan Oeam Village and a traditional house in Andong Hahoe Village to watch them from possible disasters. Total procedure of system design and implementation as well as development of the platform LinkSaaS and application services of monitoring functions implemented on the platform. We prove a good performance of our system by fulfilling TTA authentication test, web accommodation test, and operation test using real measuring data.

  • PDF

공작기계용 자동 측정 및 해석 시스템에 관한 연구

  • 박우열;정성종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 추계학술대회 논문집
    • /
    • pp.228-232
    • /
    • 1992
  • The integrated management system IMMC system) is developed for machining, measuring and checking by using IBM-PC under Borland C $\^$++/ environment. MMC system consists of following systems : DNC system, MascMC system (for measuring and checking) and MascCAM system : DNC system, MascNC system (for measuring and checking) and MascCAM system (for CAM). And some other modules support MMC system for practical usages. A vertical machining center equipped with FANUC 0MC is used for experiments. Feasibility of the system is confirmed by a large amount of experiments.

EIC integrated DCS with single console

  • Kawahara, Hiroshi;Hwa, Hong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.928-933
    • /
    • 1988
  • Control technology has been making remarkable progress in electrical control (E), instrumentation & control (I) and computer control (C) field respectively. In order to rationalize system engineering and simplify system configuration and operation work, so called, EIC are now to be integrated into one system. FUJI has developed it's own E, I&C integrated system, to meet above mentioned market requirements of variety. This paper describes basic concept of FUJI's Integrated Man-Machine Interface, hereinafter called SINGLE CONSOLE, from some view points of E, I, C integration technology.

  • PDF

LNG 저장탱크의 통합제어 안전관리 시스템에 관한 연구 (A Study on the Integrated Control and Safety Management System for a LNG Storage Tank)

  • 김청균
    • 한국가스학회지
    • /
    • 제9권1호
    • /
    • pp.44-50
    • /
    • 2005
  • 본 논문에서는 LNG저장탱크의 통압제어 안전관리 시스템에 대한 연구결과를 제시하고 있다. 통합제어 및 안전관리를 효과적으로 진행하기 위한 새로운 통합관리 시스템은 내부탱크로부터 유출되는 가스나 초저온 액체(LNG)에 의한 안전성과 누출문제를 제어하기 위해 온도, 압력, 진동과 같은 신호를 검지하고, 종합적으로 분석하여 시스템의 안전성을 확보할 수 있도록 개발된 것이다. 효율성과 안전성 향상측면에서 LNG저장탱크의 저장용량 증가경향과 최근에 발생된 저장탱크의 고장사례 고찰을 통하여, 기존의 측정장치와 안전장치는 개량되고, 새로운 기술개발이 필요하다는 것을 강조한다. 따라서 본 연구에서는 초대형 LNG저장탱크의 제어와 안전관리를 위해 새로이 개발된 통합제어 안전관리 시스템을 제시하고 있다. 이 시스템에서는 기존의 측정 및 안전장치에 대한 통합과 연계성 및 성능을 향상시키고, 특히 저장탱크 구조물의 변위량을 측정하여 안전성을 확보할 수 있도록 기능성을 새로이 추가하였다. 본 연구에서 개발된 통합제어 안전관리 시스템에 프로세스 통합관리 시스템(PIIS)을 연계하여 사용한다면, LNG 저장탱크의 안전성, 효율성, 생산성은 획기적으로 향상될 것이다.

  • PDF

Development of computer integrated system for circular error diagnosis of CMM using calibrated ring gauges

  • 박희재;김종후
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 춘계학술대회 논문집
    • /
    • pp.237-241
    • /
    • 1992
  • Error calibration and frequent reverification of coordinate measuring machines(CMMs) and machine tools are currently acknowledge as essential processes in order to maintain high performance of the machines and high quality of products. This paper shows a micro computer integrated circular error calibration system, which is fast and efficient error calibration system

AUV의 운동계측을 위한 스트랩-다운형 관성계측장치(IMU)의 개발 (A Strap-Down Inertial Measuring Unit for Motion Measurement of an AUV)

  • 이판묵;전봉환;이종식;오준호;김도현
    • 한국해양공학회지
    • /
    • 제11권1호
    • /
    • pp.95-105
    • /
    • 1997
  • This paper presents a Inertial Measuring Unit(IMU) for motion measurement of an AUV. The IMU is composed of three parts: inertial sensors with three servo accelerometers and three rate gyros, an analog/digital interface board, and a signal processing board with TMS320C31 DSP processor. The IMU is a class of strap-down inwetial navigation system does not applicable directly to the navigation system in consequence of the AUV and integrated sensors for an integrated navigation system of the AUV. Fast calculstion of direction cosine matrix for the coordinate transformation body to reference is obtained through the DSP processor. A switching algotrithm is used to lessen the low frequency drift effect of the gyros in the vertical plane with use of low pass filtering of the signal of the accelerometers.

  • PDF

Design of Management Structure Measuring Integrated Monitoring System Based on Linked Open Data

  • Min, Byung-Won;Okazaki, Yasuhisa;Oh, Yong-Sun
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2016년도 춘계 종합학술대회 논문집
    • /
    • pp.255-256
    • /
    • 2016
  • In this paper, we analyze the operations and/or status of our structure which builds the management structure measuring integrated monitoring system based on linked open data in a short term or long term bases. We have applied a novel analyzing method of linked open data to expect what movements can be occurred in the structure, and we improve the monitoring system using an integrated design to solve the drawbacks of conventional types of monitoring. And collecting data through cloud and their reliability can be proved by evaluation of soundness of data amount and their confidence.

  • PDF

심전도와 맥파 신호 검출을 위한 일체형 센서 시스템의 구현 (The Development of Integrated Sensor System for Measuring Simultaneously ECG, PPG and PPW)

  • 전계록;정동근;김기련;신범주
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.992-999
    • /
    • 2009
  • 심전도와 맥파를 측정함으로써 구해질 수 있는 맥파전달시간은 심혈관계의 상태를 진단하기 위한 의미 있는 지표가 된다. 그러나 맥파를 측정하는 동안 움직이거나, 측정 시에 가해지는 압력이 부정확할 경우, 잘못된 측정 결과를 얻을 수 있다. 이를 해결하기 위하여 본 논문에서는 심전도, 압력맥파 및 광전용적맥파를 동시에 측정할 수 있는 일체형 센서 시스템과 심전도를 지속적으로 측정할 수 있는 금속 전극을 개발하였으며, 실험을 통해 일체형 센서시스템 및 금속 전극의 유용성을 입증하였다.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.