Calibration off multiple-sensor measuring system for efficient visual inspection (형상 검사를 위한 multiple-sensor 측정 시스템의 캘리브레이션 연구)

  • 김승만;손석배;이관행
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.579-582
    • /
    • 2002
  • In acquiring the surface information of a part, two types of measuring machines have been used: contact type and non-contact type. Since each measuring device has the pres and cons, an integrated measuring system is proposed to acquire the optimal point data. In order to implement the integrated measuring system, the relationship of coordinate systems between each measuring device should be established. In this paper, a new datum fixture and a calibration method for the multiple-sensor measuring system are proposed. The datum fixture is designed to interface two machines, a CMM and a laser scanner. The position of the datum fixture is calibrated by the axis information off motorized rotation stage which is used for a part setup.

  • PDF

Implementation of an Integrated Monitoring System for Constructional Structures Based on SaaS in Traditional Towns with Local Heritage (SaaS(Software as a Service) 기반 지방유적도시 구조물 유지관리계측 통합모니터링시스템 구현)

  • Min, Byung-Won;Oh, Yong-Sun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.15-16
    • /
    • 2015
  • Measuring sensor, equipment, ICT facilities and their software have relatively short life time comparing to constructional structure so that we should exchange or fix them continuously in the process of maintenance and management. In this paper, we propose a novel design of integrated maintenance, management, and measuring monitoring system applying the concept of mobile cloud. For the sake of disaster prevention for constructional structures such as bridge, tunnel, and other traditional buildings in the village of local heritage, we analyze status of these structures in the long term or short term period as well as disaster situations. Collecting data based on mobile cloud and analyzing future expectations based on probabilistic and statistical techniques, we implement our integrated monitoring system for constructional structures to solve these existing problems. Final results of this design and implementation are basically applied to the monitoring system for more than 10,000 structures spread over national land in Korea. In addition, we can specifically apply the monitoring system presented here to a bridge of timber structure in Asan Oeam Village and a traditional house in Andong Hahoe Village to watch them from possible disasters. Total procedure of system design and implementation as well as development of the platform LinkSaaS and application services of monitoring functions implemented on the platform. We prove a good performance of our system by fulfilling TTA authentication test, web accommodation test, and operation test using real measuring data.

  • PDF

공작기계용 자동 측정 및 해석 시스템에 관한 연구

  • 박우열;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.228-232
    • /
    • 1992
  • The integrated management system IMMC system) is developed for machining, measuring and checking by using IBM-PC under Borland C $\^$++/ environment. MMC system consists of following systems : DNC system, MascMC system (for measuring and checking) and MascCAM system : DNC system, MascNC system (for measuring and checking) and MascCAM system (for CAM). And some other modules support MMC system for practical usages. A vertical machining center equipped with FANUC 0MC is used for experiments. Feasibility of the system is confirmed by a large amount of experiments.

EIC integrated DCS with single console

  • Kawahara, Hiroshi;Hwa, Hong-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.928-933
    • /
    • 1988
  • Control technology has been making remarkable progress in electrical control (E), instrumentation & control (I) and computer control (C) field respectively. In order to rationalize system engineering and simplify system configuration and operation work, so called, EIC are now to be integrated into one system. FUJI has developed it's own E, I&C integrated system, to meet above mentioned market requirements of variety. This paper describes basic concept of FUJI's Integrated Man-Machine Interface, hereinafter called SINGLE CONSOLE, from some view points of E, I, C integration technology.

  • PDF

A Study on the Integrated Control and Safety Management System for a LNG Storage Tank (LNG 저장탱크의 통합제어 안전관리 시스템에 관한 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.44-50
    • /
    • 2005
  • This paper presents integrated control and safety management system for a LNG storage tank. This system is for collecting and analyzing the temperature, pressure, and vibration signals in which are used to control and guarantee the system safety and leakage control from the inner gas tank. Based on the investigations of LNG tank related failures and accidents, we strongly recommend the modification and new development of current safety related measuring and control systems because the LNG tank is constructed bigger and bigger in recent years for the efficiency and safety increments. Thus, this paper presents newly developed integrated control and safety management system for a large LNG storage tank. This system provides the enhanced measuring and control systems, and new displacement based safety system, which may detect and control the deformation properties of tank structures. In addition, we recommend that the new integrated control and safety management system should be coupled by process integrated innovation system (PIIS) for an increased safety, efficiency, and productivity of LNG tanks.

  • PDF

Development of computer integrated system for circular error diagnosis of CMM using calibrated ring gauges

  • 박희재;김종후
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.237-241
    • /
    • 1992
  • Error calibration and frequent reverification of coordinate measuring machines(CMMs) and machine tools are currently acknowledge as essential processes in order to maintain high performance of the machines and high quality of products. This paper shows a micro computer integrated circular error calibration system, which is fast and efficient error calibration system

A Strap-Down Inertial Measuring Unit for Motion Measurement of an AUV (AUV의 운동계측을 위한 스트랩-다운형 관성계측장치(IMU)의 개발)

  • 이판묵;전봉환;이종식;오준호;김도현
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.95-105
    • /
    • 1997
  • This paper presents a Inertial Measuring Unit(IMU) for motion measurement of an AUV. The IMU is composed of three parts: inertial sensors with three servo accelerometers and three rate gyros, an analog/digital interface board, and a signal processing board with TMS320C31 DSP processor. The IMU is a class of strap-down inwetial navigation system does not applicable directly to the navigation system in consequence of the AUV and integrated sensors for an integrated navigation system of the AUV. Fast calculstion of direction cosine matrix for the coordinate transformation body to reference is obtained through the DSP processor. A switching algotrithm is used to lessen the low frequency drift effect of the gyros in the vertical plane with use of low pass filtering of the signal of the accelerometers.

  • PDF

Design of Management Structure Measuring Integrated Monitoring System Based on Linked Open Data

  • Min, Byung-Won;Okazaki, Yasuhisa;Oh, Yong-Sun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.255-256
    • /
    • 2016
  • In this paper, we analyze the operations and/or status of our structure which builds the management structure measuring integrated monitoring system based on linked open data in a short term or long term bases. We have applied a novel analyzing method of linked open data to expect what movements can be occurred in the structure, and we improve the monitoring system using an integrated design to solve the drawbacks of conventional types of monitoring. And collecting data through cloud and their reliability can be proved by evaluation of soundness of data amount and their confidence.

  • PDF

The Development of Integrated Sensor System for Measuring Simultaneously ECG, PPG and PPW (심전도와 맥파 신호 검출을 위한 일체형 센서 시스템의 구현)

  • Jeon, Gye-Rok;Jung, Dong-Keun;Kim, Gi-Ryun;Shin, Bum-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.992-999
    • /
    • 2009
  • The pulse transit time(PTT), which is determined by measuring the electrocardiogram(ECG) and pulse wave, gives comprehensive information about the cardiovascular system. However, a little movement of body and/or inaccurate pressure applied to skin during the measurement of pulse wave leads to acquire incorrect results. To overcome such problem, we developed an integrated sensor system which makes it possible to measure ECG, pressure pulse wave(PPW) and photoplethysmograph(PPG) at the same time. Futhermore, we implemented a new metal electrode which enables to continuously measure ECG. We verified that both integrated sensor system and new electrode provide useful effect.

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.