• Title/Summary/Keyword: Integrated Generator

Search Result 279, Processing Time 0.031 seconds

A GUI Module Generator for Integrated Esterel/C++ simulation (통합된 Esterel/C++시뮬레이션을 위한 GUI 코드자동생성)

  • Liu, Sujuan;Rim, Kee-Wook;Lee, Jaeho;Han, Taisook
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2007.11a
    • /
    • pp.779-781
    • /
    • 2007
  • Nowadays, as the increasing functionality and scales of embedded systems, system design grows more complex than before. So verification and simulation of systems become an important facet in hardware-software co-design issues. But it is almost impossible to simulate an embedded system without real hardware implementation or environment communication, especially for control-dominated reactive systems. Therefore, in this paper, we will introduce a GUI environment module generator for integrated Esterel\C++ simulation. By generating the GUI modeling environment, we can simulate and verify the whole embedded system conveniently.

Characteristics of the Integrated Steam Generators for a Liquid Metal Reactor

  • Sim Yoon Sub;Kim Eui Kwang
    • Nuclear Engineering and Technology
    • /
    • v.36 no.2
    • /
    • pp.127-141
    • /
    • 2004
  • Various types of integrated steam generators, which integrate IHTS and a steam generator into a single unit of equipment for an LMR, were analyzed using an analytic solution with some simplification. The analysis showed that the undesirable reversed heat transfer, of which occurrence was previously observed only in an integrated single-region bundle type, can also occur in an integrated double-region bundle type. The mechanism of the reversed heat transfer occurrence in the double-region type is explained and it is shown the mechanism in the double-region type is completely different from that in the single-region type. Based on this finding, a method for preventing the aforementioned heat transfer is suggested. The performance of the four types of the integrated steam generators is assessed. For this assessment, a SG is actually designed for each type and the optimization in the geometric parameters and flow rate are optimized.

Development of Integrated Start-up and Excitation System for Gas Turbine Synchronous Generator (가스터빈 동기기 통합형 기동 및 여자시스템 개발)

  • Ryu, Hoseon;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.183-188
    • /
    • 2014
  • Power conversion systems used in large gas turbine power plant can be divided into two main part. Because of the initial start-up characteristic of the gas turbine combustor, the gas turbine must be accelerated by starting device(LCI : Load Commutated Inverter) up to 10%~20% of rated speed to ignite it. In addition, the ECS(Excitation Control system) is used to control the rotor field current and reactive power in grid-connected synchronous generator. These two large power conversion systems are located in the same space(container) because of coordination control. Recently, many manufactures develop high speed controller based on function block available in the LCI and ECS with the newest power semiconductor. We also developed high speed controller based on function block to be using these two system and it meets the international standard IEC61131 as using real-time OS(VxWorks) and ISaGRAF. In order to install easily these systems at power plant, main controller, special module and IO module are used with high speed communication line other than electric wire line. Before initial product is installed on the site, prototype is produced and tests are conducted for it. The performance results of Integrated controller and application program(SFC, ECS) were described in this paper. The test results will be considered as the important resources for the application in future.

Development of Integrated Design System for High Temperature, High Pressure Parts for Chemical Plants (화학플랜트 고온고압부 설계 효율화를 위한 일관시스템 구축)

  • Jeong Dong Gwan
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.4
    • /
    • pp.1-6
    • /
    • 1998
  • In order to increase design efficiency, it is required to design steam boiler pressure parts systematically considering daily start-stop operation and load variation. The objective of this research is to develope an integrated system for increasing design efficiency of boiler pressure parts. The developed system consists of three program modules: (1) flexibility design module for the header stub considering fatigue life, (2) fatigue limit calculation and life evaluation module for the thick-walled boiler pressure part under cyclic operation using TRD301 code, (3) drawing automation module for the header and drum producing design drawings, welding data and bill of materials.

  • PDF

A Study on the Integrated Simulation and Condition Monitoring Scheme for a PMSG-Based Variable Speed Grid-Connected Wind Turbine System under Fault Conditions (PMSG 적용 가변속 계통연계형 풍력발전 시스템의 통합 시뮬레이션 및 스위치 개방고장 진단기법 연구)

  • Kim, Kyeong-Hwa;Song, Hwa-Chang;Choi, Byoung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.65-78
    • /
    • 2013
  • To analyze influences under open fault conditions in switching devices, an integrated simulation and condition monitoring scheme for a permanent magnet synchronous generator (PMSG) based variable speed grid-connected wind turbine system are presented. Among various faults in power electronics components, the open fault in switching devices may arise when the switches are destructed by an accidental over current, or a fuse for short protection is blown out. Under such a faulty condition, the grid-side inverter as well as the generator-side converter does not operate normally, producing an increase of current harmonics, and a reduction in output and efficiency. As an effective way for a condition monitoring of generation system by online basis without requiring any diagnostic apparatus, the estimation schemes for generated voltage, flux linkage, and stator resistance are proposed and the validity of the proposed scheme is proved through comparative simulations.

A Sensitivity Study of a Steam Generator Tube Rupture for the SMART-P (SMART 연구로의 증기발생기 전열관 파열사고 민감도 분석)

  • Kim Hee-Kyung;Chung Young-Jong;Yang Soo-Hyung;Kim Hee-Cheol;Zee Sung Quun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.32-37
    • /
    • 2005
  • The purpose of this study is for the sensitivity study f9r a Steam Generator Tube Rupture (SGTR) of the System-integrated Modular Advanced ReacTor for a Pilot (SMART-P) plant. The thermal hydraulic analysis of a SGIR for the Limiting Conditions for Operation (LCO) is performed using TASS/SMR code. The TASS/SMR code can calculate the core power, pressure, flow, temperature and other values of the primary and secondary system for the various initiating conditions. The major concern of this sensitivity study is not the minimum Critical Heat Flux Ratio(CHFR) but the maximum leakage amount from the primary to secondary sides at the steam generator. Therefore the break area causing the maximum accumulated break flow is researched for this reason. In the case of a SGIR for the SMART-p, the total integrated break flow is 11,740kg in the worst case scenario, the minimum CHFR is maintained at Over 1.3 and the hottest fuel rod temperature is below 606"I during the transient. It means that the integrity of the fuel rod is guaranteed. The reactor coolant system and the secondary system pressures are maintained below 18.7MPa, which is system design pressure.

Research of High Efficiency Integrated Reforming System Using Separated Reforming System (분리형 개질기를 이용한 고효율 일체형 개질기 개발에 관한 연구)

  • PARK, SANG-HYOUN;KIM, CHUL-MIN;SON, SUNG-HYO;JANG, SE-JIN;KIM, JAE-DONG;BANG, WAN-KEUN;LEE, SANG-YONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.11-18
    • /
    • 2018
  • A high efficiency integrated reforming system for improving the efficiency of the 5 kW PEMFC system used as the back up power of building was studied. The separated reforming system consisted of three parts - A steam reformer with two stage concentric circular shape, a heat exchanger type steam generator and a CO shift reactor. Temperature and steam carbon ratio (SCR) were control variables during operation. The operating conditions were optimized based on the thermal efficiency of the steam reformer as reformate gas composition changes at different temperature. In experiments, water was fully vaporized in the steam generator up to SCR 3.5 and the maximum thermal efficiency was achieved at the operating temperature around $700^{\circ}C$ in the steam reforming reactor. With the results of the separated reforming system research, we improved the shape of high efficiency integrated reformer. The performance evaluation of the integrated reformer was based on optimized operating conditions in SCR 3.5. As a result, the developed integrated reforming system maintained an efficiency of 76% and constant performance over 3,000 hours.

5.8GHz 25W Microwave Wireless Power Transmission System Development and Measurement (5.8GHz 25W 무선전력전송 시스템 개발 및 측정)

  • Lee, Seong Hun;Son, Myung Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.1
    • /
    • pp.21-24
    • /
    • 2019
  • In this paper, 5.8GHz 25W microwave wireless power transmission system was developed. The transmission system is composed of a signal generator, a 1W drive amplifier, a 25W power amplifier, and a circularly polarized transmission antenna. The receiving system was fabricated with an integrated receiver that combines a circularly polarized receiving antenna, a pass band filter, and an RF-DC converter. And a multi-integrated receiver had twelve parts, including an integrated receiver. Under the conditions, voltage and current were measured for the system at 5cm intervals from a minimum distance of 5cm to a maximum distance of 80cm. The power was calculated for the system. The results of the system are shown in tables and graphs. The power decreases with distance, but the power does not drop sharply due to a multi-integrated receiver.