• Title/Summary/Keyword: Intaking water

Search Result 17, Processing Time 0.025 seconds

Determination of Optimum Water Intaking Depth Based on Phytoplankton Distribution in Unmun Reservoir (식물플랑크톤 분포도에 따른 운문호의 선택취수 수심 결정)

  • Baek, In-Ho;Kim, Chul-Ho;Lee, Jung-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.3 s.91
    • /
    • pp.311-318
    • /
    • 2000
  • The purpose of this study was to determine the optimum water intaking depth for water treatment plant based on the changes of phytoplankton distributions in Unmun reservoir. Sampling was carried around of intaking tower near the Dam site at monthly intervals from February to Ocotber in 1998. Total 79 phytoplankton taxa were observed and they were classified into 4 varieties, 75 species within 51 genera. Diatoms were mainly dominated from February to July. However Rhodomonas sp. was a dominant species in August, and Microcystis ichthyblabe in September and October. Cell density of 122,800 cells/mL in October was the highest, and 415 cells/mL in May was the lowest. The pattern of vertical distribution was similar until May; however, the cell density in the epilimnion was much higher than it in the hypolimnion during the periods with the high water temperature over $20^{\circ}C$ since June. The water depths showing over 5,000 cells/mL ranged from the surface to 9m in June, surface to 6m in September, and on the only surface in October. Based on water temperature and phytoplankton vertical distribution, the depth of 6m appeared to be the optimum intaking depth far water treatment plant: 75.4 to 98.0% of phytoplankton cell densities could be avoided and the temperature over $18.3^{\circ}C$ was preserved to prevent cold water damage for rice growth at the water depth during cyanobacterial blooming period in Unmun reservoir.

  • PDF

ARIMA 모형에 의한 하천수질 예측

  • 류병로;한양수
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.433-440
    • /
    • 1998
  • This study was carried out to develop the stream water quality model for the intaking station of Kongju waterworks in the Keum River system. The monthly water quality(total nitrogen and total phosphorus) with periodicity and trend were forecasted by multiplicative ARIU models and then the applicability of the models was tested based on 7 years of the historical monthly water quality data at Kongju intaking strate. The parameter estimation was made with the monthly observed data. The last one year data was used to compare the forecasted water Quality by ARU model with the observed one. The models are ARIMA(2,0,0)$\times$(0,1,1)l2 for total nitrogen, ARIMA(0,1,1)x(0,1,1)l2 for total phosphorus. The forecasting results showed a good agreement with the observed data. It is implying the applicability of multiplicative ARIMA model for forecasting monthly water quality at the Kongju site.

  • PDF

Forecasting of Dissolved Oxygen at Kongju Station using a Transfer Function Noise Model (전이함수잡음모형에 의한 공주지점의 용존산소 예측)

  • 류병로;조정석;한양수
    • Journal of Environmental Science International
    • /
    • v.8 no.3
    • /
    • pp.349-354
    • /
    • 1999
  • The transfer function was introduced to establish the prediction method for the DO concentration at the intaking point of Kongju Water Works System. In the mose cases we analyze a single time series without explicitly using information contained in the related time series. In many forecasting situations, other events will systematically influence the series to be forecasted(the dependent variables), and therefore, there is need to go beyond a univariate forecasting model. Thus, we must bulid a forecasting model that incorporates more than one time series and introduces explicitly the dynamic characteristics of the system. Such a model is called a multiple time series model or transfer function model. The purpose of this study is to develop the stochastic stream water quality model for the intaking station of Kongju city waterworks in Keum river system. The performance of the multiplicative ARIMA model and the transfer function noise model were examined through comparisons between the historical and generated monthly dissolved oxygen series. The result reveal that the transfer function noise model lead to the improved accuracy.

  • PDF

Effects of Intaking of Red Ginseng Products on Human Platelet Aggregation and Blood Lipids (홍삼류의 섭취가 사람 혈소판의 응집반응 및 혈중 지질에 미치는 영향)

  • 이정희;박화진
    • Journal of Ginseng Research
    • /
    • v.22 no.3
    • /
    • pp.173-180
    • /
    • 1998
  • Thrombogenesis and atherosclerosis are mainly caused by platelet aggregation, blood coagulation, and hyperlipidemia. Platelet aggrelation, activated platelet thromboplastin time (APTT) were measured as indexes of blood coagulation and lipid contents in the subjects who have taken red ginseng products (e.g. water extract, tea, drink etc.) for 4 to 5 years. The platelet aggregation in the red ginseng-taking group was significantly decreased, as compared with the non-red ginseng-intaking group, when platelets were stimulated by 100 $\mu\textrm{g}$/ml of collagen (P<0.01). The atherogenic index and the ratio of triglyceride to HDL-cholesterol in blood, the risk factors of atherosclerosis, were decreased in the subjects of ginseng group, compared with that in control group. APTT was also prolonged to greater extent in ginseng group than in control group. These results suggest that long-term intake of ginseng products may help to prevent the risks of thrombogenesis and atherosclerosis.

  • PDF

Estimation of Available Permit Water for Large Scale Agricultural Reservoirs in Youngsan River Basin (영산강권역 대규모 농업용 저수지의 가용허가수량 추정)

  • Kim, Sun-Joo;Park, Ki-Chun;Park, Hee-Sung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.1
    • /
    • pp.93-97
    • /
    • 2012
  • Agricultural water reservoirs upstream of the intake on the basis of the intaking water volume is being made. Therefore, the supply capacity of reservoirs are not considered when the water balance analysis, storm water reservoirs are based on agriculture and further secured by the reservoir water is not used to using natural river water analysis. To overcome these problems can supply reservoirs are available to permit analysis of how much the quantity of water balance analysis, it should be reflected in the line to help. In this study, the natural daily flow data and apply the dimensions of the reservoir, and for more than 30 years of the long-term water balance analysis conducted by Date Youngsan river basin can supply reservoirs are large quantity of permits available is presented.

A Basic Study for Tasted and Odors Treatment and Optimum Chemical Feed in Existing Water Treatment Processes (기존 정수처리공정에서 이취미처리 및 최적 약품투입을 위한 기초연구)

  • Lim, Bong-Su;Bae, Byung-Uk;Jun, Hang-Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.94-102
    • /
    • 1996
  • This study was accomplished to get the basic data for the optimum chemical feed, evaluating interference between tastes and odors chemicals and coagulants in existing water treatment processes. During the tastes and odors occurs at D intaking tower area in 1995, PAC(Powdered Activated Carbon) feed with coagulants was PAC feed only and with coagulant simultaneously were appeared TON removal efficiency about 84%-87% within 20 min reaction time, but feed with time intervals was about 98% TON removal efficiency. Therefore in the case of PAC feed with coagulant, it is effective to feed coagulant on some time intervals in removing tastes and odors. It is not effective to feed PAC with chlorine dioxide($ClO_2$) or chlorine simultaneously in removing tastes and odors, because these chemicals were reduced the adsorption capacity of PAC.

  • PDF

Water utilities vulnerability assessment and adaption strategies for climate change in Jeju province (제주도 기후변화 관련 상수도시설 취약성 평가 및 적응대책)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.6
    • /
    • pp.517-526
    • /
    • 2018
  • Climate adaptation strategies for water utilities including 16 water treatment plants(WTPs) in Jeju were investigated. Drought, heat wave, and heavy rain were among the most significant climate factors affecting water utilities in Jeju. Heat wave increases water temperature, which in turn increases the concentration of algae, color, and odor materials. Some adaption strategies for the heat wave can be strengthening water monitoring and introducing advanced water treatments. Heavy rain increases raw water turbidity in surface water. The 7 WTPs that take raw water from streams or springs had a maximum turbidity of less than 50 NTU under heavy rain. However, due to concerns of turbidity spike in treated water, some WTPs discontinued intaking raw water when raw water turbidity increased more than 2 NTU. They instead received treated water from other WTPs which took groundwater for water supply. This happens because of the low skills of employees. Thus, there needs to be an increase in operator competency and upgrade of water facilities for the adaption of heavy rain. To improve adaption for the drought, there should be an increase in the capacity of intake facilities of surface water as well as a decrease in water loss. In addition, water consumption per person should be decreased.

Estimation of Greenhouse Heating performance for Ground Filtration Water Source Heat Pump (강변여과수 열원 히트펌프 온실난방 성능시험)

  • Moon, Jongpil;Lee, Sunghyoun;Kwon, Jinkyung;Kang, YounKoo;Lee, Sujang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.200.2-200.2
    • /
    • 2011
  • This study was carried out in order to estimate the greenhouse performance for Ground filtration water source heat pump which was installed for supplying the heat to the paprika greenhouse in Jinju city. Experimental area of Greenhouse was $3,300m^2$, For keeping the heat from greenhouse, single plastic covering and double thermal screen was installed. With considering all of greenhouse insulation condition and designed heatng temperature, heating capacity for experimental greenhouse was calculated as 320,000kcal/hr. Coefficient of performance(COP) of Ground filtration water source heat pump was gauged and greenhouse heating performance was tested from Febuary 1 to Febuary 28 in 2011. The result showed that COP of heat pump was in the range of 3.7~4.7 and COP of heating system was in the range of 3.0~3.5. The vaule of COP was very high and the temperature inside greenhouse was well corresponded to the setting temperature of greenhouse environment controlling system. lots of Ground filtration water made the the number of well fewer and the expense for installing heating system cheaper than that of geothermal system used custmarily. and this system went beyond the limitation of intaking amount of groundwater in normal Groundwater source heat pump.

  • PDF

Analysis of Benomyl by Liquid Chromatography/Time-of-Flight Mass Spectrometer and Its Occurrence in the Environment

  • Seo, Yong-Chan;Kim, Kee D.;Kim, Nack-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.432-436
    • /
    • 2002
  • Benomyl, one of the known endocrine disrupting chemicals, was analyzed to understand the fate in the nature. Water, sediment and biota samples are acidified to hydrolyze benomyl into carbendazim then followed by extraction and concentration. The concentrations of carbendazim in the samples were determined by liquid chromatography/time-of-flight mass spectrometer. Analysis data showed that certain amount of carbendazim was accumulated in sediment. On the contrary, no sign of accumulation in biota was observed probably due to the increased degradation rate in vivo. It is, however, that no one can claim carbendazim is not harmful to biota, since carbendazim may give a negative effect against organisms at the point of intaking.

Experiment Study on Field Applicability of Siphon as a Intake Facility of Agricultural Reservoir for Disaster Prevention (재해대비 농업용저수지 취수시설로서 사이폰의 현장적용성에 관한 실험적 연구)

  • Yang, Young Jin;Lee, Tae Ho;Oh, Sue Hoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.103-110
    • /
    • 2018
  • Most of the intake facilities of small agricultural reservoirs are conduits and they are regarded as serious defects due to the structural weakness that penetrates the body of the dam, and countermeasures are needed. This study suggests the application method of siphon type water intake facility by hydraulic model test and physical scale model test of siphon type water intake facility which has high safety and easy maintenance. Experimental results show that sufficient flow rate can be secured for the purpose of intaking water according to the differential head between the reservoir and the discharge part, and the flow rate can be controlled by the valve. The negative pressure was -31.5 kPa, and vibration and noise did not occur during the operation of the siphon. The maximum flow velocity in the discharge outlet was 1.11 m/s which meets the criterion for irrigation canals. Therefore, scour risk would be very low. As a result of the inflow distribution experiment, even if the inflow part is separated by only about 0.8 m, the flow velocity is remarkably decreased, so that the clogging by debris would not appear. When the pump was operated only once for the first time and the inside of the siphon was filled with water, continuous operation was possible by only valve operation. The results of this study are expected to be used for the design guidelines of the water intake facilities and improve safety and maintenance convenience of agricultural reservoirs.