• Title/Summary/Keyword: Insulators

Search Result 652, Processing Time 0.032 seconds

Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition (환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술)

  • Park, Jae-Jun;Choi, In-Hyuk;Kim, Jeong-Boo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.10
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

A Study on the Electrical Characteristics of Organic Thin Film Transistor, OTFT With Plasma-Treated Gate Insulators (Plasma 처리한 유기 절연층을 갖는 유기 박막 트랜지스터의 전기적 특성 연구)

  • 김연주;박재훈;강성인;최종선
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.3
    • /
    • pp.99-102
    • /
    • 2004
  • In this work the electrical characteristics of organic thin film transistors with the surface-treated organic gate insulator have been studied. For the surface treatment of gate dielectric, Ar plasma was used. Pentacene and PVP were used as active and dielectric layers respectively. Pentacene was thermally evaporated in vacuum at a pressure of about $10^{-6}$ Torr and at a deposition rate of 0.5 $\AA$/sec. PVP was spin coated and cured at $100^{\circ}C$. before pentacene deposition. organic thin film transistors with surface-treated gate insulators have provided improved operation characteristics.

Insulation Characteristics for a Conduction-Cooled HTS SMES

  • Cheon H.G.;Baek S.M.;Seong K.C.;Kim H.J;Kim S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.39-43
    • /
    • 2005
  • Toward the practical applications, on operation of conduction-cooled HTS SMES at temperatures well below 77 K should be investigated, in order to take advantage of a greater critical current density of HTS and considerably reduce the size and weight of the system. Recently, research and development concerning application of the conduction-cooled HTS SMES that is easily movement are actively progressing in Korea. Electrical insulation under cryogenic temperature is a key and an important element in the application of this apparatus. However, the behaviors of insulators for cryogenic conditions in air or vacuum are virtually unknown. Therefore, this work focuses on the breakdown and flashover phenomenology of dielectrics exposed in vacuum for temperatures ranging from room temperature to cryogenic temperature. Firstly, we summary the insulation factors of the magnet for HTS SMES. And a surface flashover as well as volume breakdown in air and vacuum has been investigated with two kind insulators. Finally, we will discuss applications for the HTS SMES including aging studies on model coils exposed in vacuum at cryogenic temperature.

A Study on the Microstructure Analysis and Dielectric Properties of Porcelain Suspension Insulators (자기제 현수애자의 미세구조분석과 유전특성에 관한 연구)

  • Kim, Chan-Yeong;Kim, Ju-Yong;Song, Il-Geun;Lee, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.641-647
    • /
    • 1999
  • The paper provides the results of microstructure analysis and dielectricproperties of porcelain suspension insulators. The evaluation of characteristics was also made as a function of the manufacturers and fabricated years for the experimental specimens which had been used in real distribution lines. Even though the series A contained higher alumina contents than the series B, the densification of series A was lower than that of series B, resulting from much porosity. The microstructure investigation confirmed that series A had much porosity than series B. The series A contained quartz $(SiO_2),\; mullite\; (Al_6Si_2O_{13}),\; corundum(Al_2O_3),\; and cristobalite\; (SiO_2)$ phases. However, the series B had no cristobalite phase which had very high thermal expansion coefficient. Also, the tan$\delta$of series A was more abruptly increased than that of series B as increasing temperature. The elevated temperature may make much expansion of cristobalite crystal than other crystals, resulting in crack and puncture inside cap during the summer days.

  • PDF

Effects of the Moisture on the Overall Heat Transfer Through Heat Insulators Opaque Envelopes (불투명 외피의 열관류에서 단열재의 습도영향)

  • Lee, S.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.63-69
    • /
    • 1998
  • The heat conduction and the water vapour diffusion flow through heat insulators between hygroscopical moist building materials were measured by means of the plate method. It was found that the heat transport increases with a moisture motion occuring in the temperature drop. On his basis of simplified assumptions, the increase in the thermal conductivity was calculated from the rate of diffusion flow per unit area, which generally resulted in values inferior to the measured values. The Increase in the heat transport due to water vapour diffusion measured at a large-scale wall specimen was inferior to the one measured by means of the plate method by using a comparable arrangement of layers. The overall heat transfer caused by moisture motion is not a characteristic value of the material, but a property of the whole wall structure

  • PDF

The research for the application of polymer support insulator used in DC railway system (직류전기철도에서의 고분자 지지애자 적용에 관한 연구)

  • Lee, Gi-Sung;Kim, Yoon-Sik;Sim, Jae-Suk;Jung, Ho-Sung;Lee, Ki-Won;Cho, Ho-Ryung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.371-377
    • /
    • 2009
  • The use of polymer insulator has increased all over the world. As of 2000's KEPCO has used it fully since they introduced it in early 1990's. In Korea it is very widely used by KORAIL which uses AC 25 kV system in the ground electric car line. And It is also used in tunnel electric car line to support AT feeder line. But it has not been used in the section of DC 1500 V. In case of DC 1500 V electric railway system It is has been developed by research institutes by means of R&D projects since 2008. The user cleans porcelain insulators regularly by water because of dusts and pollution. In case of polymer insulators It is very easy to be made dirty by pollution because of the material properties and hard to be cleaned by cleansing. In accordance with these reasons It is worried about deterioration. This paper deals with anticipating problems when we apply it to DC electric railway system and the procedure for testing polymer support insulator.

  • PDF

Magnetite Crystallization in Semiconducting Glaze Frit for High Tension Electric Insulators (고전압 애자용 반도성 유약프리트에서의 Magnetite 결정화)

  • 이희수;이동인;전병세
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.4
    • /
    • pp.333-339
    • /
    • 1983
  • Semiconducting glaxe of iron system for the recent use as high Voltage porcelain insulators often showed the tendancy of unstable thermal properties. Thus the development of frit including magnetite was studied to cover the defect. In the experimental process melted and quenched frits were ground pelletized and heat-treated at various temperatures in the range of 800-1 $300^{\circ}C$ for various soaking time within 4 hours and then crystallized specimens were obtained. The speciment were studied with optical and electron microscope DTA x-ray diffractometer and electrometer The results obtained were as follows : 1) The optimum condition for the crystal growth of magnetite in the frite was the heat-treatment of $1300^{\circ}C$ for 3hrs and in this case the range of crystal size was $10-11\mu\textrm{m}$ 2) The activation energy for the crystal growth of magnetite was 21.1 kcal/mole. 3) The heat-treament at $1, 250^{\circ}C$ and $1, 300^{\circ}C$ resulted in the good thermal stability and the range of surface resistivity was $3.5{\times}10^4-4.0{\times}10^7$, /TEX> $\Omega$/$cm^2$ which was adguate to semiconducting frit. 4) The conduction mechanism seems to be due to the electron mobility rather than ion mobility and the activa-tion energy for the conduction was 0.07-0.15eV/mole for the heat-treated specimes in the range of 1, 250-1, 300C

  • PDF

Analysis of Thermo Chemically Decomposing Composites for Rocket Thermal Insulators (로켓 방화벽용 열경화성 복합재의 거동해석)

  • Lee, Sunpyo;Lee, Jung-Youn
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.4
    • /
    • pp.1-11
    • /
    • 2001
  • A theory for time-dependent, high temperature ablation of poroelastic carbon composite insulators is applied using finite element methods to determine material properties from experimental data. The theory contains important revisions to that in Lee, Salamon and Sullivan[1] by making a sharp distinction between Biots constants and permeability and setting both to analytical functions of porosity. The finite element program and material modeling has been modified to (1) more closely adhere to porous-material theory, (2) include a newly discovered analytical simplification and (3) refine the material property descriptions. Application to experimental problems and comparisons with data permit determination of Biots constants and permeability and their evolution with respect to matrix decomposition and clearly show how material parameters affect the material response, e.g., amplitude and the location of peaks with respect to temperature. In particular, the response is very sensitive to permeability and dominated by it.

  • PDF

Height & Position Control of a Power Line Inspection Robot Using Various Sensors (다양한 센서를 이용한 배전선 점검 로봇의 높이 및 자세제어)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.2
    • /
    • pp.169-175
    • /
    • 2009
  • A new wire detection algorithm for power line inspection by a mobile robot has been proposed in this paper. There have been a lot of studies in order to support the high-quality electric power. For the high-quality power supply, it is necessary to investigate the power lines and insulators before the lines or insulators were disconnected or damaged. Although Korea Electric power Corp. has made many efforts for the quality improvement, it is not enough to inspect all the power lines by human inspectors. According to this problem, it is decided to replace the human operators by the power line inspection robot. When the robots are used for the inspection, there could be several advantages, for example, the working efficiency and the prevention of accident. And also the shortage of human power for dangerous jobs can be resolved. In this paper, as a part of the development of power line inspection robot, DICRO, the sensor fusion and fuzzy control algorithms are developed to detect the wire and slope of the wire. The effectiveness of the proposed algorithms is proved by the real experiments with DICRO which is under development so far.

Diagnosis Technique of Surface Aging according to Various Environment Condition for Silicon Polymer Insulator (여러환경조건에 의한 Silicon애자의 표면열화 진단기술)

  • Park, Jae-Jun;Jung, Myeong-Yeon;Lee, Seung-Wook;Kim, Jeong-Boo;Song, Young-Chul;Kim, Hee-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.76-81
    • /
    • 2004
  • This paper presents the results of spectral analysis of leakage current waveforms on contaminated insulators under various fog and environment conditions(salt fog, clean fog, rain) The larger the leakage current during 200ms, the higer the power spectrum at 60Hz. For almost equal maximum current during 200ms, however, the spectrum at 60hz and the odd order harmonics increase emphatically when discharges occur continuously for several half-waves. If contaminated insulators suffers from high salt-density fog, the leakage current occurs with high crest value intermittently, results in the low spectrum. Analysis of leakage current data showed that this electrical activity was characterized by transient arcing behavior contaminants are deposited on the insulator surface during salt fog tests. This provides a path for the leakage current to flow along the surface of the insulator. It is important to have an indication of the pollution accumulation in order to evulate the test performance of a particular insulator. If the drop in surface resistivity is severe enough, then the leakage current may escalate into s service interrupting flashover that degrade power quality.

  • PDF