• Title/Summary/Keyword: Insulation voltages of guy insulators

Search Result 1, Processing Time 0.014 seconds

Analysis on the Power Handling Capability of Ground Navigation Loran-C Transmitting Antenna (지상항법 로란-C 송신 안테나의 출력 처리 용량 분석)

  • Jang-Han Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.5
    • /
    • pp.351-357
    • /
    • 2024
  • The power handling capacity of the Loran-C transmitting antenna for terrestrial navigation was analyzed in this paper. The power handling capacity of a shortened umbrella-type monopole antenna for terrestrial navigation is determined by the insulation voltages of the base and guy insulators used in the antenna in addition to the effective height of the antenna. In this paper, the insulation voltage of the base insulator according to the transmitting antenna power was derived, and in order to obtain the insulation voltages of the points where the antenna and the guy lines are connected, the antenna voltages for the antenna height were derived. By comparing with the insulation voltages of the insulators used, the power handling capacity of the antenna can be analyzed. As a result of comparative analysis of the insulation characteristics of the insulators used for the transmitter antenna, the guy line insulation voltages were approximately 69[kV]~128[kV] depending on the antenna output of 50[kW]~100[kW], so the method of using two guy insulators in series was appropriate, and the insulation voltages at the base of the antenna were 64.8[kV]~91.7[kV], so it was possible to have a power handling capacity that could operate the antenna output power from 50[kW] to 100[kW].