• Title/Summary/Keyword: Insulation systems

Search Result 419, Processing Time 0.027 seconds

A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l) (Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I))

  • Kang, D.S.;Lee, W.Y.;Park, C.H.;Kwak, Y.S.;Kim, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

Computer Simulation for Calculation of Thermal Insulation in Korean Folk Clothes (한복의 보온력 평가를 위한 컴퓨터 시뮬레이션)

  • 권오경;성수광
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.7
    • /
    • pp.1153-1161
    • /
    • 1997
  • The insulation provided by clothing system is usually expressed in terms of a coo units and its distribution of the body, directly affect convective, conductive, and radiant heat loss from the skin to the environment Evaporated heat loss is dependent upon fabric permeability, the amount of body surface area covered by clothing, and the pumping of air between the body and garment layers. Persons at low to medium activity levels, dressed in conventional apparel in door environments, usually do not lose a large amount of heat through evaporation. Thermal manikin technology is used to measure the resistance to heat transfer provided by clothing systems. The reciprocal of this value, 6.45 W/m2.$^{\circ}C$ is often used in calculations for convenience. The purpose of this study was to implement a research program for calculation the insulation value (clo), body surface area and basal metabolic rate of selected clothing system. The project provided for the building of an insulation data base for use in evaluating and comparing new and improved garments.

  • PDF

Chracteristics of Partial Discharge Patterns Subjected to Different Defects at the Epoxy/Rubber Interface (에폭시/고무 계면에서의 결함에 따른 부분방전 특성)

  • Kim, Dong-Uk;Kim, Jeong-Nyeon;Baek, Ju-Heum
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.199-204
    • /
    • 2002
  • In order to recognize the deterioration of insulation system by partial discharge (PD), the characteristics of PD patterns which are occurring at the interface between epoxy and rubber materials in extra high voltage cable joints, have been investigated. The artificial defects such as voids, metal particles, insulation fiber and water impregnated insulation fiber are planted between the interfaces. A high frequency partial discharge detection system was used for measuring PD signals. An analysis of the PD patterns is focused on the shape of PD pattern, phase, width and time-dependence for each artificial defect. The PD Patterns in each defect show the different behaviors and it is suggested that the precise discrimination of PD patterns could be used for the diagnosis of deterioration in the insulation systems.

An Experimental Study on the Sound Insulation Performance Characteristics due to the Variation of Ceiling Structures - Focused on the Sound-absorbing and Insulation materials - (바닥슬래브 하부 구조의 개선을 통한차음특성 변화에 관한 실험적 연구 - 흡.차음재를 중심으로 -)

  • Kim, Jun-Yup;Ki, No-Gap;Jung, Il-Ho;Jung, Hwan-Wook;Song, Min-Jung;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.506-511
    • /
    • 2000
  • The aim of this study is to suggest a fundamental data to improve the sound insulation performance of floor. To achieve the aim of this study, 8 types of sound-absorbing and sound insulation materials were installed under the slab, and the floor systems were compared to the general floor system which was composed of slab, timber frame, gypsum board and wallpaper.

  • PDF

Influence of Electrical Aging on Space Charge Dynamics of Oil-Impregnated Paper Insulation under AC-DC Combined Voltages

  • Wang, Yan;Li, Jian;Wu, Sicheng;Sun, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1512-1519
    • /
    • 2013
  • Oil-impregnated paper is a major type of insulation used in oil-filled converter transformers for both traditional and new energy systems. This paper presents and analyzes the results of the experiment conducted on the electrical aging of oil-impregnated paper under AC-DC combined voltages using the pulsed electro-acoustic (PEA) technique. The formation and dynamics of space charge affected the performance of insulation material. The electrical aged oil-paper insulation was obtained through electrical aged experiments under the voltages. Based on the PEA technique, measurements were carried out when the oil-paper insulation system was subjected to different stressing and aging times. The space charge dynamics in the bulk of the oil-paper insulation system with different aging times were measured and analyzed. Characteristic parameters such as the total charge injection amount, the total charges of fast moving and slow moving, and the distortion factor of electric field were calculated and discussed. Results show that the longer electrical aging time, the more charges trapped in the bulk of aging sample. It leads to larger distortion factor of electric field in the bulk of aging samples and accelerate degradation of oil-paper insulation under AC-DC combined voltages.

Recent Research Trends for Green Building Thermal Insulation Materials (친환경 건축물 단열재 최근 연구 동향)

  • Park, Jong-Moon;Kim, Dong-Hwan;Suh, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.14-21
    • /
    • 2012
  • The pros and cons of green building thermal insulation materials and systems have been reviewed from traditional thermal insulation materials such as mineral wool and polyurethane to new thermal insulation materials like VIP and aerogel and future insulating VIM and DIM. VIPs and aerogels with very low thermal conductivity can use for green buildings to significantly increase residential area by reducing energy consumption. Aerogels can be produced as not only opaque and but also translucent forms, thus enabling a wide range of possible building application. For building applications, there are many properties to consider like building site adaptability and mechanical strength, fire protection, cost and environmental impact.

Fabrication of Light-weight Ceramic Insulation Materials by Using Oxide Ceramic Fibers for Reusable Thermal Protection Systems (산화물 세라믹섬유를 이용한 재사용 열보호시스템용 경량 세라믹 단열소재의 제조)

  • Seongwon, Kim;Min-Soo, Nam;Yoon-Suk, Oh;Sahn, Nahm;Jaesung, Shin;Hyeonjun, Kim;Bum-Seok, Oh
    • Journal of Powder Materials
    • /
    • v.29 no.6
    • /
    • pp.477-484
    • /
    • 2022
  • Thermal protection systems (TPS) are a group of materials that are indispensable for protecting spacecraft from the aerodynamic heating occurring during entry into an atmosphere. Among candidate materials for TPS, ceramic insulation materials are usually considered for reusable TPS. In this study, ceramic insulation materials, such as alumina enhanced thermal barrier (AETB), are fabricated via typical ceramic processing from ceramic fiber and additives. Mixtures of silica and alumina fibers are used as raw materials, with the addition of B4C to bind fibers together. Reaction-cured glass is also added on top of AETB to induce water-proof functionality or high emissivity. Some issues, such as the elimination of clumps in the AETB, and processing difficulties in the production of reusable surface insulation are reported as well.

Energy Saving Effects of Green Roof in Exiting Buildings according to Different Insulation Levels (기존 노후 건물의 단열 성능에 따른 옥상 녹화 시스템 설치시 에너지 성능 변화)

  • An, Kyeong A;Han, Seung Won;Moon, Hyeun Jun
    • Journal of Korean Living Environment System
    • /
    • v.21 no.6
    • /
    • pp.959-964
    • /
    • 2014
  • Energy performance of building envelope components, including external walls, floors, roofs, windows and doors, is crutial for determining how much energy is required for heating and cooling in a building. Among various building technologies, a green roof system can be a good option for reducing heat gain and loss in new buildings as well as existing buildings for green remodeling. This paper evaluates the performance of green roof systems according to soil depth and Leaf Area Index (LAI) for existing buildings. It also attempts to quantify the energy saving effects on new and existing buildings with different insulation levels. Thermal performance of green roofs is mainly dependent on soil thickness and LAI. Installation of green roofs in deteriorated existing buildings can lead to improvements in roof insulation, due to the soil layer. An increase in soil depth leads to a decrease in heating load, regardless of conditions of vegetation on the green roof. Larger LAI values may reduce cooling loads in the cooling season. Installation of green roof in deteriorated existing buildings showed bigger energy saving effect in comparison to a case in new buildings. A simulation study showed that the installation of green roof systems in deteriorated existing buildings with low insulation levels, due to low thermal performance requirements when constructed, could improve the energy performance of the buildings similar or better to the peformance on new buildings with the most updated insulation standard. Thus, when remodeling a deteriorated building, green roofs could be a good option to meet the most recent energy requirements.

Insulation Diagnostics and Maintenance of Submarine Medium Voltage Power Cable Systems (해저 케이블 시스템의 열화진단 및 유지보수)

  • 이동영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.80-86
    • /
    • 2003
  • A study on the insulation aging assessment and maintenance for submarine medium voltage power cable systems has been performed The purpose of this work is the economic discrimination and maintenance of bad cables which is likely to cause cable system failure. 1 have found that aging status of submarine cable systems are very poor and in progress. Therefore, we have the replacement of cable terminations and repeat the diagnostic measurement Insulation status were improved with the replacement of cable terminations. I have confirmed, with the electrical md structural analysis of terminations, that the poor aging status of cables are mainly caused not by the cable insulations but by the aging of cable terminations. From the above results, I have also confirmed that the domestic diagnostic system is successful and convenient for the discrimination and maintenance of the damaged cables economically.

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.