• 제목/요약/키워드: Insulation systems

검색결과 416건 처리시간 0.026초

Structural glass panels: An integrated system

  • Bidini, G.;Barelli, L.;Buratti, C.;Castori, G.;Belloni, E.;Merli, F.;Speranzini, E.
    • Smart Structures and Systems
    • /
    • 제30권3호
    • /
    • pp.327-332
    • /
    • 2022
  • In building envelope, transparent components play an important role. The structural glazing systems are the weak element of the casing in terms of mechanical resistance, thermal and acoustic insulation. In the present work, new structural glass panels with granular aerogel in interspace were investigated from different points of view. In particular, the mechanical characterization was carried out in order to assess the resistance to bending of the single glazing pane. To this end, a special instrument system was built to define an alternative configuration of the coaxial double ring test, able to predict the fracture strength of glass large samples (400 × 400 mm) without overpressure. The thermal and lighting performance of an innovative double-glazing façade with granular aerogel was evaluated. An experimental campaign at pilot scale was developed: it is composed of two boxes of about 1.60 × 2 m2 and 2 m high together with an external weather station. The rooms, identical in terms of size, construction materials, and orientation, are equipped with a two-wing window in the south wall surface: the first one has a standard glazing solution (double glazing with air in interspace), the second room is equipped with the innovative double-glazing system with aerogel. The indoor mean air temperature and the surface temperature of the glass panes were monitored together with the illuminance data for the lighting characterization. Finally, a brief energy characterization of the performance of the material was carried out by means of dynamic simulation models when the proposed solution is applied to real case studies.

노후 공공도서관의 그린리모델링 적용 요소 조합에 따른 우선순위 도출 (Deriving Priorities Based on Combination of Green Remodeling Application Elements in Old Public Libraries)

  • 심성진;임세현;김성은;송용우
    • 토지주택연구
    • /
    • 제15권2호
    • /
    • pp.1-7
    • /
    • 2024
  • 2015년 파리 기후 협약을 시작으로 나라별로 국가 온실가스 감축 목표를 제시하고 실행하기로 합의하였다. 이에 따라 대한민국 정부는 건물 부문에서 온실가스 배출량 32.8% 감축을 목표로 설정하였다. 이를 위해 국토교통부는 2020년부터 공공건축물 그린리모델링 사업을 통해 노후 건축물의 에너지효율 강화를 추진하고 있다. 노후 건축물의 에너지 절감을 위한 그린리모델링 공사에는 패시브 및 액티브 요소의 필수공사와 선택공사가 있다. 그러나 현재는 패시브와 액티브 시스템의 통합설계가 부족하며 건축물의 노후도에 따른 적용 요소들의 우선순위에 대한 기준이 없는 실정이다. 따라서, 본 연구에서는 노후 건축물 중 많은 사람들의 이용이 가능하며 에너지 사용량이 높을 것으로 예상되는 중부 2지역에 위치한 공공도서관 6개소를 선정하였다. 공공도서관은 준공년도에 따라 Model 1~3으로 구분하였으며 각각 1980년대, 1990년대, 2000년대 준공된 건물이다. Model 1~3의 ECO2-OD를 통한 시뮬레이션 분석으로 1차 에너지소요량 절감률에 따른 상위 3개의 우선순위를 도출했다.

BES 기법을 이용한 육계사 내부 고온 스트레스 평가를 위한 THI 지수 모의 (Estimation of THI Index to Evaluate Thermal Stress of Animal-occupied Zone in a Broiler House Using BES Method)

  • 하태환;권경석;홍세운;최희철;이준엽;이동현;우샘이;양가영;김락우;여욱현;이상연;이인복
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.75-84
    • /
    • 2018
  • Thermal stress of livestock has been issued due to recent climate change trends and this causes reproductive disorders, decreased feed consumption, immunosuppression, and increased mortality of animals. Concept of THI has been widely used to quantitatively evaluate the degree of thermal stress for animals, however use of this concept is restricted for animals living in the enclosed facilities such as mechanically ventilated broiler houses. In this study, time-based internal energy flow and variation trends of temperature and humidity were analyzed based on BES technique. Local weather data, insulation characteristics of building materials, heat and moisture generation rate from broilers according to age, algorithm of ventilation operation were adopted for boundary condition of the model to accurately compute THI values inside the mechanically ventilated broiler house. From the BES computation, excess frequency of THI threshold in Jeju city was highest on the assumption that air conditioning equipments were not installed. When general raising density ($39kg\;m^{-2}$) was adopted, total 2,191 hours were exceeded. Excess hours of THI threshold were strongly related to the cumulative air temperature ($R^2=0.87$).

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

전투차량용 전기식 연료펌프의 고장분석 및 내열성능 평가 (Failure Analysis and Heat-resistant Evaluation of Electric Fuel Pump for Combat Vehicle)

  • 곽대환
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.634-640
    • /
    • 2020
  • 전투차량의 연료탱크에 설치되어 엔진으로 연료를 이송하는 장치인 전기식 연료펌프에 대하여 고장분석과 내열성능 평가가 수행되었다. 고장의 원인을 파악하기 위하여 직류 전동기가 적용된 연료펌프를 분해하여 검사를 수행하였다. 하우징 내부를 관찰한 결과를 바탕으로 고장 현상을 권선 소손, 브러시 조기 마모, 연료 혼입의 세 가지로 분류하였다. 연료펌프 내부 검사를 실시한 결과를 바탕으로, 과열에 의한 권선 소손을 고장을 발생시킨 주된 원인으로 추정하였다. 이에 따라서 전기식 연료펌프의 권선이 과열로 소손될 가능성을 확인하기 위하여 온도 센서를 고정자 표면과 브러시 홀더에 설치한 후 무부하 조건으로 24시간동안 가동을 실시하였다. 연료펌프의 주변 온도를 68 ℃로 설정하였을 때 고정자 온도는 최대 135.9 ℃까지 상승하였으며, 전동기의 고정자 및 회전자 권선이 소손되었다. 이 결과를 통해서 전기식 연료펌프를 위한 전동기 권선의 내열성능이 부족함을 확인할 수 있었으며, 이를 해결하기 위하여 현재 155 ℃ 이하에서 사용할 수 있는 절연등급 F종의 권선 및 함침액을 180 ℃ 이상에서도 사용할 수 있는 C종 이상의 절연등급으로 대체하도록 제안하였다.

압축목재를 사용한 LNG 화물창 단열시스템의 적합성 평가에 관한 연구 (A study of feasibility of using compressed wood for LNG cargo containment system)

  • 김종환;유동만;박성보;노병재;이제명
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.307-313
    • /
    • 2016
  • 액화 천연가스(LNG)를 운반, 저장하는 화물창은 LNG의 기화를 막기 위해 항상 저온의 상태로 유지되어야 한다. 이러한 극한 환경으로 인해 LNG 화물창에 적용되는 단열시스템의 기술은 상당히 중요하다. 이러한 이유로 LNG 화물창 단열시스템 내에는 구조 및 단열성능을 가지는 적층형 목재인 플라이우드(plywood)가 널리 사용되고 있다. 그러나 최근 슬로싱(sloshing)으로 인한 플라이우드의 파손현상이 보고되면서 이를 해결하기 위한 강도적인 보강이 필요할 것으로 보인다. 따라서 본 연구에서는 B타입 LNG 탱크의 지지대로 사용되는 적층형 목재인 압축목재(compressed wood)를 플라이우드를 대체하기 위한 대체 재료로 고려하게 되었다. 이를 위해 압축목재에 대해 압축 및 굽힘시험을 수행하였고 기계적 물성과 파손특성을 확인하였다. 또한 온도와 적층방향을 실험변수로 설정하여 이에 따른 압축 목재의 특성 변화를 분석하였다. 마지막으로 참고문헌을 통해 획득한 플라이우드의 물성과 실험결과를 비교하여 압축 목재의 적용가능성을 평가하였다.

SPD를 이용한 리튬이온전지용 전기저장장치의 보호방안에 관한 연구 (A Study on Protection Method of Energy Storage System for Lithium-ion Battery Using Surge Protection Device(SPD))

  • 황승욱;이후동;태동현;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.568-574
    • /
    • 2020
  • 최근, 신재생에너지원의 출력 안정화, 수요관리 및 주파수 조정 등 다양한 기능을 가지고 있는 전기저장장치(energy storage system, ESS)의 설치가 매년 증가되고 있다. 그러나, 2017년 8월에 발생한 고창 전력시험센터의 ESS 화재를 시작으로 경산 변전소, 군산 태양광발전소 등 현재까지 총 29건의 화재사고가 발생하여 많은 재산피해가 보고되고 있다. 이러한 전기저장장치의 화재사고는 전기저장장치의 용량이나 계절과는 무관하게 발생되고 있으므로, ESS의 화재원인을 정확하게 파악하고 안전성을 확보하기 위하여 ESS의 사고특성에 대한 분석이 요구되어지고 있다. 따라서, 본 논문에서는 ESS의 사고특성을 분석하고 안전성을 확보하기 위하여, 전력계통 상용해석 소프트웨어인 PSCAD/EMTDC를 이용하여 ESS의 모델링을 수행한다. 다양한 시나리오를 기반으로 ESS의 단락사고특성을 확인한 결과, 높은 사고전류로 인하여 보호기기인 퓨즈가 동작하고, 매우 큰 CMV(common mode voltage)가 발생하여 ESS의 절연이 파괴될 가능성이 있음을 확인할 수 있었다. 또한, 이러한 문제점을 극복하기 위하여, ESS의 배터리측과 PCS측에 각각 SPD를 설치한 경우, DC측 전로에서 발생하는 CMV가 3[kV] 이내로 크게 감소되어 ESS의 절연파괴를 방지할 수 있음을 확인하였다.

육계사의 차열 페인트 및 히트펌프 적용에 따른 내부 기온 변화 분석 (Analysis of Internal Temperature Change according to the Application of Thermal Insulation Paint and Heat Pump in Broilers)

  • 문준섭;김락우;이승헌;이상민;최상규
    • 생물환경조절학회지
    • /
    • 제32권3호
    • /
    • pp.197-204
    • /
    • 2023
  • 본 연구에서는 육계사에 차열 페인트와 히트펌프의 적용에 따른 내부 온도 변화를 분석 하였다. 이를 위하여 환기율, 환기 방법, 시간별 환기 변화에 따른 실험 조건을 설정하였으며 육계사 외부 및 내부 기온을 측정하였다. 그 결과, 차열 페인트를 도포한 육계사에서는 최대 1-2℃ 실내 기온 상승을 억제하는 효과가 나타났으며 히트펌프를 가동한 육계사에서는 외기 온도의 영향을 제일 적게 받는 환기율 0%일 때 내부 기온 감소가 제일 크게 나타났다. 계사 내부의 온도가 외기 온도보다 높을 경우에는 환기율을 높게 설정하여 환기팬을 이용한 냉방이 더욱 효과적이나 계사 내부 온도가 외기 온도와 유사하거나 낮을 경우에는 히트펌프를 이용하는 것이 가장 효과적일 것으로 판단된다. 히트펌프 가동 시 외기 온도의 영향이 적은 환기율을 0%로 설정하였을 때 내부 기온이 가장 큰 폭으로 감소하였으나 실제 육계사에서는 분진, 이물질, 암모니아 등을 고려하여 최소환기율 정도로 환기율을 설정한 후 히트펌프를 가동하는 것이 가장 효율적일 것으로 판단된다. 본 연구는 실험 기간이 짧아 데이터가 많지 않으며 실제 육계가 사육되고 있는 환경에서 실험을 진행한 것이 아니라는 한계가 있다. 향후 후속 연구로 실제 닭이 사육되고 있는 환경에서의 히트펌프 효과 분석과 히트펌프의 전력사용량, 냉방부하, 환기팬 가동시간 등 다양한 환경인자를 포함한 연구가 진행되어야 할 것으로 판단된다.

BES 수치모델을 이용한 사육 밀도별 가금류 고온 스트레스 평가 (Evaluation of thermal stress of poultry according to stocking densities using mumerical BES model)

  • 권경석;하태환;최희철;김종복;이준엽;전중환;양가영;김락우;여욱현;이상연
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.456-463
    • /
    • 2019
  • 가축 사육 시설 내부의 온도, 습도 등과 같은 미기상 요소는 환기, 냉방, 난방, 단열, 가축의 현열 및 잠열과 같은 에너지 발생 등 다양한 요소의 복합적인 영향을 받는다. 본 연구에서는 위와 같은 다양한 변수에 따른 시설 내부의 에너지 흐름 및 기작을 구현하기 위하여 BES 수치해석 기법을 활용하였다. BES 수치해석 모델 및 THI 지수 개념을 이용하여 국내 주요 지역별 가금 사육 시설 내부의 고온 스트레스 발생 정도를 정량적으로 산정하고자 하였다. 또한, 최근 동물복지 사육이슈에 따라, 현행 기준 및 동물복지를 고려한 사육 밀도 적용 시, 시설 내부의 THI 지수를 비교 분석하였으며, 그 결과, 환절기 시기의 경우 사육밀도 감소에 따른 유의한 고온 스트레스 감소 효과가 도출되었으나(p<0.05), 하절기의 경우 큰 차이를 보이지 않아(p>0.05) 지역별 적정 냉방시설의 설비 마련이 시급한 것으로 나타났다. 전라북도 익산시의 경우, 사육밀도 감소에 따라 고온 스트레스 발생 시간 기준, 총 252시간의 이득이 있는 것으로 산출되었다.

국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사 (Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea)

  • 정종원;유용희;송준익;김태일;전병수;양창범
    • 한국축산시설환경학회지
    • /
    • 제11권3로
    • /
    • pp.169-176
    • /
    • 2005
  • 본 연구에서는 국내 2층 돈사 및 톱밥돈사를 조사하였으며 현재 양돈에 적용되고 있는 분뇨처리 형태, 사육형태, 환기방식 및 돈사건축비의 실태를 현장조사를 통하여 분석, 평가함으로써 이를 바탕으로 우리나라 기후와 조건에 적합한 분뇨처리와 돼지사육이 가능한 고상식 돈사의 건축모델에 적용 가능성을 고려할 목적으로 무창 2층 돈사와 개방식 톱밥돈사 농장을 방문 조사한 결과를 요약하면 다음과 같다. 1. 2층 돈사의 분뇨에 수분조절재로 톱밥, 수피, 왕겨를 사용하였다. 톱밥돈사는 톱밥만을 사용하였으며, 수분조절재의 사용깊이는 대체로 $30\~60cm$로, 이용기간은 평균 $3\~6$개월 정도 이용하였다. 2. 2층 돈사에서 돼지의 사육형태는 1층에서는 주로 임신돈 및 분만돈을 사육하였고 2층은 자돈과 육성돈을 사육하고 있었다. 3. 환기시스템은 기본적으로 2층 무창돈사는 기계적 환기(mechanical ventilation)시스템을 설치하였고 톱밥돈사는 자연환기(natural ventilation)시스템으로 조합되어 있었다. 4. 2층 돈사의 단열재는 블록, 칼라강판 및 샌드위치 판넬 등을 사용하였고 단열재두께는 지붕 $75\~100mm$, 벽이 $50\~75mm$였으며 천장높이는 최소 2.0, 최대 3.0m로 조사되었다. 5. 평당 건축비는 무창 이층돈사는$70\~1,400$천원 이내였으며, 개방식 톱밥돈사는 자체 건축한 곳을 제외하고는 $300\~400$천원 내외로 건축비가 소요되었다

  • PDF