• 제목/요약/키워드: Insulation standard

검색결과 312건 처리시간 0.028초

Structural glass panels: An integrated system

  • Bidini, G.;Barelli, L.;Buratti, C.;Castori, G.;Belloni, E.;Merli, F.;Speranzini, E.
    • Smart Structures and Systems
    • /
    • 제30권3호
    • /
    • pp.327-332
    • /
    • 2022
  • In building envelope, transparent components play an important role. The structural glazing systems are the weak element of the casing in terms of mechanical resistance, thermal and acoustic insulation. In the present work, new structural glass panels with granular aerogel in interspace were investigated from different points of view. In particular, the mechanical characterization was carried out in order to assess the resistance to bending of the single glazing pane. To this end, a special instrument system was built to define an alternative configuration of the coaxial double ring test, able to predict the fracture strength of glass large samples (400 × 400 mm) without overpressure. The thermal and lighting performance of an innovative double-glazing façade with granular aerogel was evaluated. An experimental campaign at pilot scale was developed: it is composed of two boxes of about 1.60 × 2 m2 and 2 m high together with an external weather station. The rooms, identical in terms of size, construction materials, and orientation, are equipped with a two-wing window in the south wall surface: the first one has a standard glazing solution (double glazing with air in interspace), the second room is equipped with the innovative double-glazing system with aerogel. The indoor mean air temperature and the surface temperature of the glass panes were monitored together with the illuminance data for the lighting characterization. Finally, a brief energy characterization of the performance of the material was carried out by means of dynamic simulation models when the proposed solution is applied to real case studies.

건설업 직종별 노출 가능 유해인자 및 노출강도에 관한 평가 (Evaluation on Probability and Intensity of Hazards Exposure by Construction Occupations)

  • 박현희;김세동
    • 한국산업보건학회지
    • /
    • 제33권3호
    • /
    • pp.317-331
    • /
    • 2023
  • Objectives: Construction workers are exposed to various hazardous substances simultaneously. However, little is known about the exposure hazards in construction industry. This study was aimed at identifying the risk of exposure hazards among construction workers. Methods: The expert survey (n=29) was conducted, including construction industry health managers (n=11) and work environment monitoring experts (n=18), on exposure probability, intensity and risk of hazardous substances by construction occupations Results: The exposure hazards of 30 construction occupations were identified and summarized through a literature review and expert survey. The most prevalent hazards were in order of noise, awkward posture, heat/cold, crystalline silica, cement/concrete dust, metal fumes, and volatile organic compounds. The hazards with highest risk score(over seven points) at construction occupations were noise(formwork carpenter, concrete finisher, rebar worker, demolition worker, driller/rock blaster), hazardous rays(welder), heat/cold (earthworks, formwork carpenter, rebar worker, concrete placer, scaffolder), awkward posture(bricklayer, caulker/tile setter, rebar worker) and heavy lifting(bricklayer, rebar worker). Among construction workers, the job types with the highest risk of exposure to carcinogens, and in which occupational cancer has been reported, were in order of stonemason, concrete finisher, rock blaster, welder, insulation installer, painter, scaffolder, plant worker and earthworks in order Conclusions: Systematic research and discussion on occupational disease among construction workers and its various hazardous factors are needed to establish job exposure matrix for facilitating standard for promptly processing the workers' compensation.

항공기용 차폐 케이블의 구조에 따른 RTCA DO-160G Sec. 22 간접낙뢰 영향성 분석 (Analysis of Indirect Lightning Impact on Aircraft Shielded Cable Structure in accordance with RTCA DO-160G Sec. 22)

  • 김성연;김태현;김민성;이왕상
    • 항공우주시스템공학회지
    • /
    • 제17권6호
    • /
    • pp.35-45
    • /
    • 2023
  • 본 논문에서는 항공기용 차폐 케이블의 구조에 따른 간접낙뢰의 영향성을 분석하고, 차폐력 향상을 위한 차폐 케이블 구조를 분석하였다. 항공기에서 케이블은 부품 중에 가장 많은 비중을 차지하고 있고, 항공기 프레임과 전자기기들이 연결되어 있어 영향을 많이 줄 수 있다. 특히, 간접낙뢰 노이즈는 항공 전자기기 오동작 및 손상을 발생시킬 수 있어, 차폐 케이블을 활용하여 간접낙뢰 노이즈로 인한 피해를 줄일 수 있다. 항공기용 차폐 케이블의 차폐층 유무, 내심, 절연체 등의 케이블 구조에 따른 간접낙뢰 영향성 분석을 진행하였다. 또한, 간접낙뢰 공인 규격인 RTCA DO-160G Sec. 22를 적용하여 시뮬레이션 및 실험하여 검증하였다.

목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석 (Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material)

  • 서정기;정수광;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권3호
    • /
    • pp.343-359
    • /
    • 2017
  • 건축물에서 사용되는 에너지를 줄이기 위하여 다양한 연구 및 정책이 진행되고 있으나 건축물에서 구조재 및 실내 외 마감재로 폭넓게 사용되는 목재의 열적 특성에 관한 연구는 미미한 실정이다. 이에 따라, 본 연구는 목질재료와 비 목질재료의 전열성능을 분석하기 위하여 목질재료가 주로 이용되는 주거용 건축물을 대상으로 열성능이 취약한(열교 발생) 부위를 선정하고, 각 부위별로 구조재와 마감재의 구성에 따라 총 16 Case에 대해 전열성능 분석을 실시하였다. 전열 해석 시뮬레이션 도구는 ISO 10211의 계산 방법을 따르는 Physibel Trisco를 이용하였다. 해석 부위의 모델링 역시 ISO 10211에서 제시된 기준에 의해 실시하였으며, 경계 온도 조건은 에너지절약설계기준에 따라 실내온도 $20^{\circ}C$, 실외온도 $-11.3^{\circ}C$(서울 기준)로 설정하였다. 구조는 콘크리트구조와 비 목질재료마감, 콘크리트구조와 목질재료마감 그리고 목구조에 목질재료마감의 경우에 따라 구분하였다. 부위는 벽체, 지붕, 층간바닥 및 최하층 바닥 등으로 구분하여 시뮬레이션을 진행하였다. 결과로서, 콘크리트구조의 경우 형상적 원인에 의해, 목구조의 경우 형상적인 원인에 재료적 원인이 더해져 다발적으로 열교가 발생함을 확인할 수 있었다. 추가적으로 콘크리트구조에서는 단열재의 불연속 부위에서 구조적인 열교가 발생하고 목구조에서는 구조적인 열교와 이질재료의 적용 부위에서 재료적 원인에 의한 열교가 발생하는 것을 확인할 수 있었다. 또한 콘크리트 구조에 목질 실내마감재를 적용하였을 경우에는 벽체의 선형 열관류율 값이 감소하는 것을 확인할 수 있었다.

학교시설의 녹색건축 활성화를 위한 인증현황 분석 연구 - 경기도 학교시설을 중심으로 - (An Analysis on Current Status of Certification for Green Building Revitalization in School - Focused on the School Located in Gyeonggi-do Province -)

  • 김장영;김성중;이승민
    • 교육녹색환경연구
    • /
    • 제14권3호
    • /
    • pp.9-17
    • /
    • 2015
  • 본 논문에서는 경기지역을 대상으로 학교시설의 녹색건축 활성화를 위한 검증 기준인 녹색건축인증, 건축물 에너지효율등급, 에너지절약계획에 대한 항목별 적용 여부 및 계획수준을 분석하였다. 분석결과 녹색건축인증은 항목 채택 시 추가 비용이 들어가는 항목 및 유지관리가 어려운 항목은 채택비율이 낮은 것으로 분석되었다. 또한, 에너지효율등급은 학교시설 특성상 비교적 단순한 형태와 일정한 규모로 계획되고 고효율기자재 사용비율이 높아 다른 용도의 건축물에 비해 높은 등급을 보였다. 그리고 에너지성능지표(EPI)의 경우 지역별로 부문별 취득 점수에 차이가 있는 것으로 분석되었다. 특히, 경기지역의 경우 타 부문 대비 건축부문에 대한 적용점수가 낮은 것으로 나타나 단열성능 강화 시 보다 높은 점수를 취득할 수 있을 것으로 사료된다. 3가지 기준에 대한 분석결과, 다수의 시설이 학교가 취득해야 하는 의무 획득 기준에만 맞춘 형식적인 계획으로 인해 건물별 특성을 고려하지 않고 기존 획득 항목에만 맞춰 최소한의 기준만 만족하여 계획하는 패턴을 보였다. 그러나 학교시설은 녹색건축물의 확대라는 목표와 더불어 학생들의 녹색교육을 위한 토대가 되어야 하는 의무를 지닌 상징적인 건축물이다. 따라서 시설의 특성을 파악하고 건축물을 기획하는 단계부터 다양하고 합리적인 평가항목 적용이 이루어지도록 고려한 계획이 필요할 것으로 판단된다.

출력 리플 저감을 위한 LED 드라이버의 주회로 방식 특성 비교 (Comparison of Main Circuit Type Characteristics of LED Driver for Output Ripple Reduction)

  • 박대수;김태경;오성철
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.491-499
    • /
    • 2019
  • 최근에, 전원 공급 장치에 있어서 파워의 품질에 대한 요구가 높아지고 있다. IEC 61000-3-2 규격은 조명을 위한 AC/DC 전원 공급 장치에 대하여 역률(PF)과 전체 파형 왜곡률(THD)에 대한 규격을 만족하도록 요구하고 있다. 또 출력단의 전류 변화에 의해 발광체 광량이 바뀜에 따라 발생되는 플리커 현상에 대해 유럽권 선진국가는 ripple rate의 기준을 15~30%로 설정해 규제하고 있다. 따라서 국내에서도 기준을 마련하고 규제를 추진 중에 있다. 그래서 본 논문은 PFC 규격을 만족하고, 회로 1차, 2차 간 절연 기능을 가지기 위해 Flyback 컨버터를 적용하며, LED 전류의 저주파 리플을 저감하기 위해 Flyback, Coupled Inductor, LC 병렬 공진 필터, LLC 공진 필터, Cuk을 이용한 각각의 LED 구동회로를 PSIM을 통해 시뮬레이션 함으로써 각각의 방식들을 비교하였으며, 출력측 리플 저감을 위해 1차측에 Coupled Inductor와 2차측에 LC 공진을 적용한 Coupled LC 공진 회로를 제안하였으며, Coupled LC 공진 방식은 출력 커패시터가 78uF으로 작으며, 출력 리플은 전압 2.38V, 전류 0.05A로 기존의 방식보다 22%의 출력 리플 저감을 확인 하였다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구 (A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency)

  • 장현숙;이상호
    • 한국건설관리학회논문집
    • /
    • 제13권6호
    • /
    • pp.3-12
    • /
    • 2012
  • 최근 민간건축 경기 침체가 거듭되면서 '신축' 시장 대비 비용 절감 효과는 물론, 자원절약 및 환경보호 효과를 거둘 수 있다는 긍정적인 반응과 함께 에너지성능향상형 리모델링 시장의 규모가 확대되고 있다. 서울시의 경우 2008년 시범사업을 시작으로 기존 건물에 대해 '건물에너지이용합리화사업(BRP)'를 추진, 시설개선사업을 통해 에너지 절감 및 이용 효율을 향상시킬 수 있도록 융자지원을 하고 있다. 2012년 보도자료에 따르면 254개소의 민간건축물이 참여, 친환경녹색건축물로 조성됨에 따라 온실가스 4만 1천톤/년을 감축, 석유환산 시 1만4천 TOE의 절감에 해당되어 매년 75억원의 에너지비용 절감효과를 보이고 있다고 한다. 본 연구는 기존 건물의 에너지 효율화 대책으로 리모델링 시 우선적으로 고려해야 할 에너지성능향상 방안 중 건축적 요소인 외피를 연구범위로 설정, 그 방안을 모색하였다. 그리고 해석모델에 적용, 분석함으로써 기존 건물의 에너지 절감효과, 즉 건물의 에너지성능향상 효과를 제시하였다. 연구의 범위가 외피 리모델링만을 고려한 건물의 에너지사용량을 감소시키는 단열보강 등의 목적지향적인 방법일 수 있겠으나, 대부분의 비주거용 업무시설의 경우 임대형이라는 점을 고려하였을 때 건축적 기술만을 적용한 방법의 모색은 실제 리모델링 시 가장 보편적인 기초자료가 될 수 있으므로 연구의 의미가 있다고 할 수 있다.

국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사 (Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea)

  • 정종원;유용희;송준익;김태일;전병수;양창범
    • 한국축산시설환경학회지
    • /
    • 제11권3로
    • /
    • pp.169-176
    • /
    • 2005
  • 본 연구에서는 국내 2층 돈사 및 톱밥돈사를 조사하였으며 현재 양돈에 적용되고 있는 분뇨처리 형태, 사육형태, 환기방식 및 돈사건축비의 실태를 현장조사를 통하여 분석, 평가함으로써 이를 바탕으로 우리나라 기후와 조건에 적합한 분뇨처리와 돼지사육이 가능한 고상식 돈사의 건축모델에 적용 가능성을 고려할 목적으로 무창 2층 돈사와 개방식 톱밥돈사 농장을 방문 조사한 결과를 요약하면 다음과 같다. 1. 2층 돈사의 분뇨에 수분조절재로 톱밥, 수피, 왕겨를 사용하였다. 톱밥돈사는 톱밥만을 사용하였으며, 수분조절재의 사용깊이는 대체로 $30\~60cm$로, 이용기간은 평균 $3\~6$개월 정도 이용하였다. 2. 2층 돈사에서 돼지의 사육형태는 1층에서는 주로 임신돈 및 분만돈을 사육하였고 2층은 자돈과 육성돈을 사육하고 있었다. 3. 환기시스템은 기본적으로 2층 무창돈사는 기계적 환기(mechanical ventilation)시스템을 설치하였고 톱밥돈사는 자연환기(natural ventilation)시스템으로 조합되어 있었다. 4. 2층 돈사의 단열재는 블록, 칼라강판 및 샌드위치 판넬 등을 사용하였고 단열재두께는 지붕 $75\~100mm$, 벽이 $50\~75mm$였으며 천장높이는 최소 2.0, 최대 3.0m로 조사되었다. 5. 평당 건축비는 무창 이층돈사는$70\~1,400$천원 이내였으며, 개방식 톱밥돈사는 자체 건축한 곳을 제외하고는 $300\~400$천원 내외로 건축비가 소요되었다

  • PDF

저독성 내화전선 케이블의 성능평가에 관한 연구 (A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.18-23
    • /
    • 2002
  • 저독성 폴리올레핀 절연재료, Sheath재료의 저독성, 연기밀도특성, 연소가스부식성 분석을 하기 위하여 저독성 내화케이블의 성능평가 시험을 수행하였다. 화재 발생시 화염확산 및 유독성가스발생의 주원인으로 피난안전계획에 매우 중요하다. 90년대 후반기부터 연이어 발생한 씨랜드 화재사고와 인천 인현동 라이브클럽등의 동일한 유형을 가진 화재사건을 계기로 국내 내화케이블에 사용되는 재료가 화재시 인명참사에 미치는 영향이 크다는 점이 발견되었다. 본 연구에서는 고체물질에서 발생하는 연기의 특성광학밀도를 ASTM E662를 근거로 하여 실험을 하였다. 전기로의 시스템은 20분동안 밀폐된 챔버내에서 2.5$\pm$0.04w/$\textrm{cm}^2$을 지닌 조사열량을 일정한 상태 하에서 방사를 유지할 수 있도록 하였다. NFR-8과 FR-PVC 연기밀도의 분해 결과에 따라 완전연소에 의한 연기밀도 최대값 NFR-8은 25.2에서 39.6 FR-PVC에서 51.1의 값을 얻을 수 있었다. 비연소 열분해에 의한 연기밀도 최대값 NFR-8은 100.4에서 112.2 FR-PVC는 126.5에서 398.8의 값을 얻을 수 있었다. 또한 시료의 연기밀도 분석결과 PVC가 폴리올핀 시료보다 상당히 많은 양의 CO가 발생되는 반면 $CO_24의 양은 적게 발생하였다.