Characteristics of Insulation Aging in High Voltage Cables (고압케이블의 절연열화 특성)

  • Kim, Kyeong-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.88-88
    • /
    • 2010
  • High Voltage cross-linked polyethylene (XLPE) cables are widely used in a thermal power plant. These cables had been in service for 26 years. The insulation condition of six 6 kV XLPE cables was estimated by insulation diagnostic analyzer (IDA) with voltage amplifier. IDA was measured dissipation factor and capacitance of the whole cable as a function of frequency and voltage. This system measures in the frequency range from 0.1 to 10 Hz at each voltage level. Six XLPE cables are judged good condition, but three cables are analyzed at an aged condition.

  • PDF

A Study on the Development of PD Simulation Pulse Generator for Evaluation of GIS Diagnosis System (GIS 진단시스템의 평가를 위한 PD 모의 펄스발생기 개발에 관한 연구)

  • Kim, Sungju;Chang, Sughun;Cho, Kook-hee
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • The expansion and stable operation of electric power facilities are important factors with development of industrial facilities in modern society. In high-voltage equipment such as GIS, the insulation characteristics may be deterioated by environment-friendly gas adaption and miniaturization. There is also the possibility of accidents due to insulation breakdown due to the deterioration of power facilities. Therefore, it is necessary to extend the diagnosis system to continuously monitor the danger signals of these power equipment and to prevent accidents. Most of the internal defects in the GIS system are conductive particles, floating electrode defects, protrusion defects, and the like. In this case, a partial discharge phenomenon is accompanied. These partial discharge signals occur irregularly and various noise signals are included in the field, so it is difficult to evaluate the reliability in the development of the diagnostic system. In this paper, a study was made on equipment capable of generating a partial discharge simulated signal that can be adjusted in size and frequency to be applied to a diagnostic device by electromagnetic wave detection method. The PD simulated pulse generator consists of a user interface module, a high-voltage charging module, a pulse forming circuit, a voltage sensor and an embedded controller. In order to simulate the partial discharge phenomenon similar to the actual GIS, a discharge cell was designed and fabricated. The application of the prototype pulse generator to the commercialized PD diagnosis module confirmed that it can be used to evaluate the performance of the diagnostic device. It can be used for the development of GIS diagnosis system and performance verification for reliability evaluation.

A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation (XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구)

  • Gang, Dong-Sik;Seon, Jong-Ho;Kim, Wi-Yeong;Lee, Hong-Sik;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.

Insulation Diagnostics and Maintenance of Submarine Medium Voltage Power Cable Systems (해저 케이블 시스템의 열화진단 및 유지보수)

  • 이동영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.80-86
    • /
    • 2003
  • A study on the insulation aging assessment and maintenance for submarine medium voltage power cable systems has been performed The purpose of this work is the economic discrimination and maintenance of bad cables which is likely to cause cable system failure. 1 have found that aging status of submarine cable systems are very poor and in progress. Therefore, we have the replacement of cable terminations and repeat the diagnostic measurement Insulation status were improved with the replacement of cable terminations. I have confirmed, with the electrical md structural analysis of terminations, that the poor aging status of cables are mainly caused not by the cable insulations but by the aging of cable terminations. From the above results, I have also confirmed that the domestic diagnostic system is successful and convenient for the discrimination and maintenance of the damaged cables economically.

The Study on tree growth in XLPE using PD patterns (부분방전 패턴을 이용한 가교폴리에틸렌에서의 트리성장에 관한 연구)

  • Kang, Dae-Yong;Wu, Guangning;Shin, Chang-Myon;Park, Myoung-Seop;Cho, Kyu-Bock;HwangBo, Seung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.941-943
    • /
    • 1998
  • Exploitation of equipment with cross linked polyethylene (XLPE) insulation requires its condition monitoring and diagnostic. Traditionally diagnostics of insulation is carried out by means of partial discharge detection. Many researchers have developed a lot of methods to identify the defect by the PD form. However, such identification of a defect, for example, void, inclusion or treeing, does not say about its danger from a point of view of full insulation gap breakdown and insulation construction failure. The information about the form and size of formed upon high voltage treeing is necessary for prediction of the remained resource of XLPE insulation. For this purpose we carry out experimental research for determination of the dependencies between PD characteristics in XLPE upon time and three dimension PD patterns of corresponding treeing. The investigations were carried out by means of electrical measurement of PD current and simultaneous optical recording of treeing image. Test results show that the PD patterns can be applied for detecting tree growth well.

  • PDF

The Insulation Design of Enclosure for Diagnostic Device in Extra High Voltage Line (초고압 선로 진단장치용 외함 절연설계)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.3
    • /
    • pp.201-207
    • /
    • 2015
  • In this paper, in order to avoid equipment malfunction due to electromagnetic waves, which can occur when high-voltage live line diagnostic device fabrication, the enclosure structure of the diagnostic device with power lines that can minimize the EMI (electromagnetic interference) was modeled using the FEM (finite element method). Simulation examined the strength of the electric field in the required thickness, material and regions where there is a control board while changing the curvature radius of the corner making the enclosure, and By applying a mechanical design and simulation results that occur during the actual production has been designed for the final design. Most of the simulation results for the electric field is concentrated in the final model, the inner edge of the enclosure could be confirmed that the stable structure.

Insulation Diagnosis Study of Power XLPE Cable by Used Atenna (안테나를 이용한 전력용 케이블의 절연진단 연구)

  • Lee, H.C.;Choie, U.H.;Park, K.S.;Yoon, D.H.;Jee, S.W.;Lee, S.H.;Kim, C.N.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1805-1807
    • /
    • 2004
  • This simulated partial discharge caused by 22.9[kV] power cable using XLPE(Peroxide Crosslinkable Polyethylene) insulation having the outside damage. Asone of the insulation diagnostic method a radiated electromagnetic waves were measured by an UHF method using a BiconiLog antenna(EMCO-3142) and a spectrum analyzer used to measure EMl, EMC. From results of this study, It was confirmed that discharge progress were possible to be estimated by the proposed method.

  • PDF

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

Example study of the dissipation factor change according to the oil filtering in large oil-filled transformer (유입변압기 오일필터링에 따른 유전정접 변화사례 고찰)

  • Kong, Tae-Sik;Kim, Hee-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2035_2036
    • /
    • 2009
  • This paper is purpose to understand the dissipation factor properties of the oil-filled large transformer according to the oil filtering. In order to know the insulation characteristic change by insulating oil filtering, we carried out the insulation diagnostic test for the same transformer before oil filtering and after. The insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, Especially we took notice of dissipation factor change, we analyzed and made a comparison of the two cases test result.

  • PDF

Estimation of Electrical & Physical Characteristics by Thermal History in XLPE Insulation (XLPE 절연체에서의 열이력에 의한 전기, 물리적 특성 평가)

  • Lee, Sang-Jin;Shim, Sung-Ik;Jeon, Seung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.183-184
    • /
    • 2008
  • The aim of this study is to find out the effects of thermal aging condition on dielectric strength and degree of crtstallinity of XLPE insulation. Thermal properties of XLPE insulation were investigated by DSC(differential scanning calorimetry) and dielectric strength were analyzed using AC BDV tester. Aging of XLPE samples were conducted through different four conditions. The degree of crtstallinity and AC BDV were changed by thermal history. From these results, it can be suggested that DSC and AC BDV test are suitable for diagnostic method of extra high voltage XLPE cable.