• 제목/요약/키워드: Insulation Strength

검색결과 641건 처리시간 0.023초

요소수지(尿素樹脂) 연질(軟質) 왕겨보드의 개발(開發) (Development of Rice Hull Insulation Board using Urea Formaldehyde Resin)

  • 이화형;강춘원
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권4호
    • /
    • pp.50-55
    • /
    • 1998
  • This study was carried out to develop low density board made of rice hull which needs proper use. Urea formaldehyde adhesive(UF) was used. The raw materials were the mixtures of the rice hulls from IllFum, DongGin, ChuChong, etc. The physical and mechanical properties of rice hull insulation board were examined. The results are as follows : For the thickness of 15mm of the low density rice hull board bonded with UF resin, proper manufacturing conditions were $171^{\circ}C$ of hot pressing temperature with thickness bar for optimum density, 12 percent of resin solid contents of rice hull ovendry weight, and 20 minutes of hot pressing time. These conditions meet Korean standards(KS 3201-1982) in relation to free formaldehyde emission, bending strength, water absorption and heat resistance.

  • PDF

무기 내화 단열재 개발을 위한 제주도 현무암의 화학조성에 대한 연구 (A Study on the Chemical Compositions of Jeju Basalt for the Development of an Inorganic Insulation Material)

  • 강명보;감상규;김남진
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권3호
    • /
    • pp.1-6
    • /
    • 2019
  • The basalt fiber, which is found to be non-toxic and harmless to the human body, is expected to become a trend for industrial fibers as they have better properties of non-combustion, heat-resistant, soundproof, absorbent, moistureproof, wear-resistant, corrosion resistant, lightweight, and high strength properties. Thus, in this study, we analyzed the chemical compositions of basalt produced at seven sites on Jeju Island for making a high value inorganic insulation material. The results showed that the MgO content of basalt collected from the eastern part of Jeju Island was higher than 7.5 percent, while that of the western region was less than 6 percent.

폐타이어 분말을 혼입한 몰탈의 단열특성 (An Adiabatic Characteristic on the Waste tyre Powders Mortar-Containing)

  • 최재남;손기상
    • 한국안전학회지
    • /
    • 제20권2호
    • /
    • pp.105-112
    • /
    • 2005
  • This is to find out that cement mortar mixed with waste tie particle can be applied for recycling it and enhanced to have shock absorption capacity. Therefore, architectural material specification and its related references for the disposal of it are based on for the study. Test has been performed with procedure, based on the Korea Standard insulation mortar and Compressive Strength Test has been done at K remicon factory approved by Korea Government in Korea, in order to decrease any possible error in mixing procedure. Test molds far insulation capacity and cohesive strength have been delivered to the expert agency for having more exact results. The result from the above test shows that waste tyre mixed with cement mortar has almost equal to the common concrete. This means that the recycling of the waste t)re will be demanded more and more in case of having continued development for this recycling area. And also waste t)to-using construction material can be more applied for construction area than existing material. Thus, this recycling method can be very usefully applied for solving environmental problem and for establishing economic aspect.

A predicting model for thermal conductivity of high permeability-high strength concrete materials

  • Tan, Yi-Zhong;Liu, Yuan-Xue;Wang, Pei-Yong;Zhang, Yu
    • Geomechanics and Engineering
    • /
    • 제10권1호
    • /
    • pp.49-57
    • /
    • 2016
  • The high permeability-high strength concrete belongs to the typical of porous materials. It is mainly used in underground engineering for cold area, it can act the role of heat preservation, also to be the bailing and buffer layer. In order to establish a suitable model to predict the thermal conductivity and directly applied for engineering, according to the structure characteristics, the thermal conductivity predicting model was built by resistance network model of parallel three-phase medium. For the selected geometric and physical cell model, the thermal conductivity forecast model can be set up with aggregate particle size and mixture ratio directly. Comparing with the experimental data and classic model, the prediction model could reflect the mixture ratio intuitively. When the experimental and calculating data are contrasted, the value of experiment is slightly higher than predicting, and the average relative error is about 6.6%. If the material can be used in underground engineering instead by the commonly insulation material, it can achieve the basic requirements to be the heat insulation material as well.

폐비닐골재를 사용하는 아스팔트 콘크리트의 물리적 성질 (Physical Properties of Asphalt Concrete Using Wasted Vinyl Aggregates)

  • 김병준;김영진;박주영;정진훈
    • 한국도로학회논문집
    • /
    • 제15권2호
    • /
    • pp.73-81
    • /
    • 2013
  • PURPOSES : In this study, various laboratory tests were performed to investigate basic physical properties of the asphalt concrete which uses wasted vinyl aggregates. METHODS : The thermal conductivity, ultrasonic velocity, Marshall stability, flow, indirect tensile strength were measured according to binder content and wasted vinyl aggregate content. An experimental construction was performed to verify construct ability of the asphalt pavement using the wasted vinyl aggregates. RESULTS : The thermal conductivity and ultrasonic velocity decreased showing insulation effect by mixing more wasted vinyl aggregate, whereas stability and flow increased. The void ratio shows similar value regardless of the mixing ratio. The highest indirect tensile strength was measured at 2.5% of wasted vinyl aggregate content. The construct ability was verified by observing the process of mixing, placing, and compaction and the state of the pavement surface. CONCLUSIONS : The basic properties and construct ability of the asphalt concrete using the wasted vinyl aggregates were verified. The temperature according to pavement depth will be measured to verify the insulation effect of the wasted vinyl aggregates. In addition, amount of snowfall, snowmelt area, and ice adhesion strength will be analyzed quantitively.

이중버블시트를 적용한 매트 기초콘크리트의 부위별 온도이력 특성 (Characteristics of Temperature History at Each Section of Mat Foundation Concrete Applying Double Bubble Sheets)

  • 김태청;김종;전충근;신동안;오선교
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.13-14
    • /
    • 2016
  • This study is aimed to analyze temperature history at each section of mat foundation concrete applying double bubble sheets. The results of the study are as follows. Firstly, the results of measuring the temperature history indicate that the lowest external temperature has been recorded at -5.6℃ for the three-day measurement period. For the central section, the result indicates that the lower, center and upper part have all secured the concrete curing temperature of 18℃ or higher. This results are believed to have resulted from excellent heat insulation performance of double bubble sheets. For the edge section between the edge form and the concrete interface, the temperature has been measured, on average, approximately 12℃ lower than the central section. However, all measured sections have indicated the temperature of 5℃ or higher. Meanwhile, an analysis has been conducted through the estimation equation of compressive strength of maturity during the curing period in order to examine the possibility of early frost damage and the aspect of securing strength. It has been confirmed that the compressive strength is higher than 50°D·D, namely, 5MPa, on the 3rd day of the aging process, which allows early frost damage to be avoided.

  • PDF

멤브레인 LNG선 방열시스템 동적강도 해석적 특성평가 (Numerical Assessment of Dynamic Strength of Membrane Type LNG Carrier Insulation System)

  • 이준환;김태우;김명현;김화수;노병재;최익흥;이제명
    • 대한조선학회논문집
    • /
    • 제44권3호
    • /
    • pp.305-313
    • /
    • 2007
  • The aim of present paper is to investigate the dynamic strength characteristics of LNG cargo containment system under sloshing impact loads numerically. The dynamic stress transmission mechanism under the impact load was analyzed based on the dynamic Finite Element Analysis. Based on the insights obtained from the numerical studies, the characteristics of internal stress distribution and stress concentration have been reported. The material option including anisotropic material features required for the commercial FEA code application were suggested based on the comparison with the experimental results.

Synthesis and Properties of High Voltage Silicone Rubber by Platinum-based Flame Retardant

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.283-292
    • /
    • 2006
  • So that high-strength and electrical properties apply by excellent high voltage insulator electricity material, ATH content and platinum-based flame retardant that influence in flame retardant and tracking characteristic among composite of silicone rubber studied mechanical strength and influence getting to electrical properties. Composition of ${\alpha}$, ${\omega}-vinyl$ poly (dimethyl-methylphenyl) siloxane(VPMPS) of a polymer quantity made doing mole of D4, $D3^{Me,Ph}$ and VMS by 1000:15:0.2 mole ratio and uses basic catalyst tetramethylammonium silanolate(TMAS) and do opening equilibrium polymerization to be used to main polymer for high voltage insulation insulator. Control ATH content and content of platinum-based flame retardant and made high voltage insulation silicone rubber. Measured mechanical strength of making silicone rubber using UTM, and tracking characteristic according to standard of IEC 60587, flame retardant test studied effect that flame retardant characteristic gets in tracking characteristic, measuring according to UL94V method of test.

에폭시/마이크로실리카/나노실리카 혼합 콤포지트의 열적, 전기적 특성 (Thermal, Electrical Properties for Epoxy/Microsilica/Nanosilica Composites)

  • 강근배;권순석;박재준
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.779-785
    • /
    • 2012
  • The epoxy/micro-and nano-mixed silica composites(EMNC) systems were prepared and the AC insulation breakdown strength was evaluated. Glass transition temperature (Tg) and crosslink density were also measured by dynamic mechanical analyzer(DMA) in order to correlate them with the electrical and mechanical properties, and the effect of silane coupling agent on the electrical properties was also studied. Electrical properties and crosslink density of epoxy/micro-silica composite were noticeably improved by addition of nano-silica and silane coupling agent, and the highest breakdown strength was obtained by addition of 0.5~5 phr of nano-silica and 2.5 phr of silane coupling agent, and the highest tensile and flexural strength were obtained by addition of 2.5 phr of nano-silica.

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.