• Title/Summary/Keyword: Insulation Resistance

Search Result 513, Processing Time 0.041 seconds

Condition Diagnosis by the Complex Accelerating Degradation for fault Prediction & estimation of reliability on the traction motor - Insulation Resistance & Polarization Index Properties (견인전동기의 고장예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 절연저항 및 성극지수 특성 연구)

  • Wang, Jong-Bae;Byun, Yoon-Sub;Baek, Jong-Hyen;Park, Hyun-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1374-1376
    • /
    • 2000
  • In this paper, sample coils for stator form-wound winding of traction motor were tested by the accelerative thermal degradation, which composed of heat, vibration, moisture and overvoltage applying. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, insulation resistance and PI properties were investigated as diagnosis tests in the range of $20{\sim}160^{\circ}C$. Analysis of polarization properties was performed on the base of do current-time change.

  • PDF

The Evaluation of Thermal Aging Characteristics in Insulating Materials of the Pole Transformers (가속열화 방법에 의한 주상변압기 절연물의 열 열화 특성 평가)

  • 이병성;송일근;이재봉;한상옥
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1136-1141
    • /
    • 2003
  • The primary insulation materials used in an oil filled transformer are kraft paper, wood, porcelain and oil. Modern transformers use chemically treated paper to improve its tensile strength and resistance to aging caused by immersion in oil. But these insulation papers are mainly aged by thermal stress. Over the life time of the insulation paper and oil, it is exposed to high temperatures, oxygen and water. Its interaction with the steel of the tank and core plus the copper and aluminium of the windings will eventually cause the chemical properties of the oil to decay. High temperature have an effect on mechanical strength of cellulous paper used in the layer insulation. We made two aging cells in which insulation papers and mineral oil are conducted to test thermal properties. It is measured dielectric strength, number of acid, moisture, etc. of insulation paper and oil aged in the aging cells.

A Study on the Reduction Characteristics of Floor Impact Sound Insulation Due to the Ceiling Frame Structures in Apartment Houses (공동주택의 천장틀구조 변화에 따른 바닥충격음 차음특성 연구)

  • 정환욱;기노갑;송민정;김선우
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.573-580
    • /
    • 2002
  • Generally the ceiling frame of apartment house is made of wood. But the wood frame has several problems due to the natural properties such as distortion by shrink, low fire resistance and material loss in the construction field. And it has some defections in sound insulation performance. Therefore it is necessary to develop a new method that can be used as a ceiling frame. This study aims to analyze and to compare the sound insulation characteristics against the floor impact sound between wood ceiling frame and M-bar frame which is made of steel. The results of this study are like these. M-bar frame is more effective than wood ceiling frame in sound insulation. And sound absorbing or sound insulation materials which can be Put on gypsum board are helpful to improve floor impact sound insulation performance.

Insulation Deterioration of AC/DC Section Insulators for Electric Railroad Catenary. (전기철도 교/직 절연구분장치의 절연열화 현상)

  • 최규형
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.1
    • /
    • pp.16-22
    • /
    • 2003
  • While passing through the AC/DC section insulators installed at electric railroad catenary, some electric trains undergo mis-operation of main circuit breaker after AC/DC change-over operation. This paper provides insulation resistance measurements of AC/DC section insulators, which confirm the insulation levels of section insulators are below the standard of insulators. The insulation deterioration and pantograph arrangement on the electric train can produce voltage impression on section insulator which induces mis-operation of main circuit breaker To mitigate the insulation deterioration of the section insulator installed at underground railroads, the section insulators have been cleaned periodically, but section insulator structure should be modified to make the section insulator performance perfect. Based on the above analysis, effective modification method of AC/DC section insulator is provided.

The estimation on the insulation performance of thermal insulation materials according to water vapor permeance (투습성에 따른 단열재의 단열성능평가 및 고찰)

  • Kim, Seok-Hyun;Park, Jong-Il;Lee, Min-Woo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1012-1018
    • /
    • 2006
  • In this study, the insulation performance of thermal insulation materials such as glass wool, polyetylene and flexible lastomeric foam according to water vapor permeance was estimated by using experimental correlation equation. The results showed the conductivity increment of flexible lastomeric foam which has very low-permeability (${\le}0.15[ng/{\cdot}s{\cdot}Pa]\;or\;{\mu}{\ge}1,000$) is about 50% lower than that of glass wool with the lapse of ten years. The conclusion is that moisture inevitably accumulated in permeable Insulations reduces insulation performance and also accelerates surface condensation in the case of cold water system.

  • PDF

Comparative Study on the Thermal Insulation of Membrane LNG CCS by Heat Transfer Analysis (열전달 해석을 이용한 멤브레인형 LNG 화물창의 단열구조 성능비교)

  • Hwang, Se-Yun;Lee, Jang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • This study discusses the thermal insulation capacity of variant of NO96 LNG (liquefied natural gas) cargo containment insulation system. Changing the insulation materials and the insulation layers of conventional GTT NO96 containment system, The thermal resistance and BOR(boil off rate) caused by the heat transfer between cryogenic and environmental temperature is discussed. Therefore, thermal analysis of LNG CCS(cargo containment system) is carried out to determine the insulation capabilities. Also, BOR is evaluated in terms of the total amount of heat invaded into CCS(cargo containment system). Variant of NO96 CCS such as NO96, NO96GW and NO96L3 membrane type during laden voyage is selected for the comparative study. Finite element model for heat transfer analysis is conducted by employing the equivalent thermal resistance model to simplify the complex insulation layers. Finally the results for each variant model are relatively compared and discussed to minimize the BOR.

On-Line Insulation Diagnosis Techniques for Stator Winding of Rotating Machines (회전기 고정자 권선에서의 운전 중 절연열화 진단기법)

  • 윤대희;황돈하;신병철;김용주;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.89-93
    • /
    • 2000
  • Recently many research activities on the diagnosis of stator winding insulation of large rotating machines have been reported. Capacitive couplers are widely used as sensors for on-line partial discharge (PD) measurement of high voltage rotating machines. This paper presents laboratory test to compare Stator Slot Coupler (SSC), Resistance Temperature Detector (RTD), 80 [pF] coupler and 500 [pF] coupler for on-line PD measurement of rotating machines. And a novel on-line monitoring system for an insulation diagnosis is proposed.

  • PDF

Thermal Insulation Life Prediction of EPDM rubber Used for Electrical Insulation (고압절연용 EPDM rubber의 내열수명 예측)

  • Lee, Chul-Ho;Jeon, Young-Jun;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1408-1410
    • /
    • 1997
  • Arrhenius plots are useful in predicting long-term use temperatures of organic materials and in choosing parameters for accelerated aging. The effects of antioxidant on the heat resistance and temperature index of EPDM rubber used for electrical insulation were investigated. The short-time points were obtained by 50% retention of elongation at break.

  • PDF

Effect of Ceramic Powder Content and Shape on the Electrical Properties of Ceramic(BaTiO3)-polymer(Epoxy) Composite for Embedded Capacitors (임베디드 커패시터용 세라믹(BaTiO3)-고분자(에폭시) 필름의 세라믹 분말 형상 및 함량에 따른 전기적 특성)

  • Han, Jeong-Woo;Yoon, Jung-Rag;Je, Hae-June;Lee, Dong-Ho;Lee, Kyung-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.6
    • /
    • pp.495-500
    • /
    • 2009
  • The ceramic($BaTiO_3$)-polymer(epoxy) composites have been widely investigated as dielectric materials for embedded capacitors in printed circuit boards (PCBs). The dielectric properties of $BaTiO_3$/epoxy composites prepared using the agglomerated $BaTiO_3$ particles were investigated in the present study. The dielectric constants of the composites prepared using the agglomerated $BaTiO_3$ particles were about 2 times higher than those of the composites with the dispersed $BaTiO_3$ particles. The insulation resistance of the composites prepared using the agglomerated $BaTiO_3$ particles were lower than those of the composites with dispersed $BaTiO_3$ particles. As a result, there is tradeoff between high dielectric constant and insulation resistance in the $BaTiO_3$/epoxy composites. So it is important to select proper agglomerated or dispersed $BaTiO_3$ particles in accordance with needs.

Transient loss analysis of non-insulation high temperature superconducting coil using the field-based data profiling method

  • Hoon Jung;Yoon Seok Chae;June Hee Han;Ji Hyung Kim;Seung Hoon Lee;Ho Chan Kim;Young Soo Yoon;Ho Min Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.38-42
    • /
    • 2023
  • The evaluation of no-insulation (NI) high-temperature superconducting (HTS) typically uses the lumped equivalent circuit (LEC) model. Constant parameters in the NI HTS LEC model accurately predict voltage and central magnetic field at currents below the critical current. However, it is difficult to find constant circuit parameters that simultaneously satisfy the measured voltage and magnetic field under overcurrent conditions. Recent research highlights changes in contact resistance during transient conditions, which may impact power loss estimation in NI HTS coils. Therefore, we confirm the influence of contact resistance changes on loss calculation in the transient state for NI HTS coil. To achieve this, we introduce a measurement data analysis method based on the LEC model and compare it with the LEC model using constant circuit parameters.